5 1 4 1 3 1 2 1 1
<br />N
<br />IC
<br />IFJ1
<br />SURFACE CLEANOUT
<br />CONCRETE PAD
<br />GRADE
<br />TWO WAY CLEANOUT
<br />01 2-WAY GRADE CLEANOUT DETAIL Nm
<br />\ MAY EXTEND AS WASTE OR
<br />VENT
<br />WALLCOVER WALL
<br />AND SCREW
<br />PLUGGED TEE WITH
<br />CLEANOUT
<br />FLOOR LINE
<br />m
<br />1 /8 C.I. BEND
<br />BALANCE OF PIPING SAME
<br />AS FLOOR CLEANOUT
<br />�2 WALL CLEANOUT DETAIL Nm
<br />PLUMBING
<br />LEGEND
<br />SYMBOL
<br />ABBREV.
<br />DESCRIPTION
<br />W
<br />WASTE PIPING
<br />- --� -- -
<br />(E) W
<br />EXISTING WASTE PIPING
<br />- - - - - -
<br />V
<br />VENT PIPING
<br />•
<br />CW
<br />COLD WATER PIPING
<br />HW
<br />HOT WATER PIPING
<br />- - -
<br />HWR
<br />HOT WATER RETURN PIPING
<br />WCO
<br />WCO
<br />WALL CLEAN OUT
<br />OR %I"
<br />VTR
<br />VENT THRU ROOF
<br />OR
<br />FCO
<br />FLOOR CLEAN OUT
<br />OR
<br />GCO
<br />GRADE CLEAN OUT
<br />e
<br />POINT OF NEW CONNECTION
<br />0
<br />KEYNOTE
<br />&I
<br />BALL VALVE
<br />HOSE BIBB
<br />MATERIAL SPECIFICATIONS:
<br />1. DOMESTIC HOT AND COLD WATER PIPING TO BE SCH 40 CPVC WITH SOLVENT WELDED
<br />FITTINGS ABOVE GROUND.
<br />2. SANITARY WASTE AND VENT PIPING SHALL BE DWV SCHEDULE 40 PVC ABOVE AND BELOW
<br />GRADE.
<br />3. INSULATION SHALL BE FLEXIBLE UNICELLULAR -SELF -SEAL ARMAFLEX 2000 3/4" THICK FOR
<br />HOT WATER PIPING UP TO 2" SIZE - PROVIDE SHEET METAL SADDLES AT EACH HANGER.
<br />FIXTURE SPECIFICATIONS:
<br />WC-1 WATER CLOSET, BARRIER FREE - AMERICAN STANDARD, CADET RIGHT HEIGHT NO. 2467.016, FLOOR MOUNTED, FLOOR
<br />OUTLET, 16.5" HIGH, TANK TYPE, ELONGATED BOWL PRESSURE -ASSISTED SIPHON JET FLUSH ACTION, CLOSE COUPLED
<br />FLUSHOMETER TANK, VITREOUS CHINA, 1.6 GPF, EVERCLEAN@SURFACE INHIBITS THE GROWTH OF STAIN- AND
<br />ODOR -CAUSING BACTERIA, MOLD, AND MILDEW ON THE SURFACE. CENTOCO NO. 1500STSCCSS OPEN FRONT SEAT LESS
<br />COVER, STAINLESS STEEL CHECK HINGE. 1 /2"CW, 4" SAN.
<br />LAV-1 LAVATORY, BARRIER FREE - AMERICAN STANDARD LUCERENE NO. 0355.012, 20X18" VITREOUS CHINA, WALL HUNG, 4"
<br />CENTERS, PROVIDE WITH EXTRA RIGHT HAND HOLE. PROVIDE FLOOR CARRIER WITH CONCEALED ARMS. TWO -LEVER
<br />FAUCET - HC - DELTA NO. 2599-HGMHDF, CHROME FAUCET, TWO -LEVER HANDLE, 1/2 GPM FLOW RESTRICTOR, GRID
<br />DRAIN ASSEMBLY. HC FINISH - TOP OF FRONT RIM MOUNTED 34" FROM FINISHED FLOOR. PROVIDE STOPS, SUPPLIES,
<br />TRAP, ETC., TO MAKE A COMPLETE INSTALLATION. INSULATE TRAP AND SUPPLIES WITH TRUEBRO NO. 103 LAV GUARD.
<br />1/2" CW, 1/2- HW, 1-1/4" SAN.
<br />SH-1 SHOWER - DELTA NO. T14238-H2O, PRESSURE -BALANCED MIXING VALVE WITH SINGLE LEVER HANDLE, INTEGRAL
<br />SERVICE STOPS, 1.5 GPM SPRAY SHOWER HEAD. ZURN SHOWER FLOOR DRAIN NO. FD-2254-S5-PB, POLISHED BRASS
<br />STRAINER, PVC BODY. PROVIDE TRAP, ETC., TO MAKE A COMPLETE INSTALLATION. 1/2-CW, 1/2" HW, 2" SAN.
<br />TWO COMPARTMENT SINK - ELKAY, LUSTERTONE NO. LR-3322, 33X22X8" STAINLESS STEEL DOUBLE COMPARTMENT
<br />SINK, SELF RIMMING, 3 FAUCET HOLES. FAUCET NO. LK-2432-BH, HI -ARC SWING SPOUT, BLADE HANDLES. LK-335
<br />DUO STRAINER, AERATOR. PROVIDE STOPS, SUPPLIES, TRAPS, ETC. TO MAKE COMPLETE INSTALLATION. 1/2" CW, 1/2"
<br />HW, 1-1/2" SAN. PROVIDE WITH IN-SINK-ERATOR, MODEL EVOLUTION COMPACT, 3/4 HP, 1725 RPM, 120 V/1 PH, 8.1
<br />AMPS, STAINLESS STEEL GRINDING COMPONENTS.
<br />SHOWER - AMERICAN STANDARD NO. 1662.601, PRESSURE -BALANCED MIXING VALVES WITH LEVER HANDLE, 60" HOSE
<br />WITH VACUUM BREAKER, HAND HELD SHOWER AND SLIDE BAR, ZURN SHOWER FLOOR DRAIN NO. FD-2251-SS,
<br />STAINLESS STEEL SLOTTED STRAINER, CAST IRON BODY. PROVIDE TRAP, ETC., TO MAKE A COMPLETE INSTALLATION.
<br />1 /2"CW, 1/2" HW, 2" SAN.
<br />WCO WALL CLEAN OUT - ZURN NO. CO2411/CO2530-SS7, SMOOTH STAINLESS STEEL ACCESS COVER, PVC PLUG AND BODY.
<br />SIZE TO PIPE SIZE.
<br />FCO FLOOR CLEAN OUT - ZURN NO. CO2450-PV, POLISHED BRONZE ACCESS COVER, PVC BODY, PROVIDE WITH CARPET
<br />MARKER FOR CARPETED SURFACES. MATCH TO PIPE SIZE.
<br />PLUMBING SPECIFICATIONS:
<br />ALL WORK SHALL COMPLY WITH APPLICABLE NATIONAL, STATE, AND LOCAL CODES. THIS SHALL INCLUDE, BUT NOT BE
<br />LIMITED TO, THE 2010 FLORIDA PLUMBING CODE.
<br />REVIEW PLANS OF ALL TRADES PRIOR TO BIDDING AND INSTALLATION TO INCLUDE ALL PLUMBING FOR COMPLETE SYSTEMS
<br />SHOWN ON THE PLANS AND AS REQUIRED.
<br />COORDINATE WITH OTHER TRADES TO PREVENT INTERFERENCE WITH HVAC DUCTS, STRUCTURE, ELECTRICAL LIGHTING AND
<br />OTHER PIPING IN THE CEILING SPACE. VENT PIPING AND WATER PIPING SHALL BE HELD EITHER ABOVE OR BELOW HVAC
<br />DUCTWORK AS COORDINATED WITH THE HVAC CONTRACTOR.
<br />ALL CHANGES SHALL BE REVIEWED BY THE ARCHITECT.
<br />COORDINATE WITH ARCHITECTURAL DRAWINGS BEFORE ROUGHING -IN PLUMBING FIXTURES AND EQUIPMENT SUPPLIES.
<br />THE PLUMBING SUBCONTRACTOR SHALL FURNISH AND INSTALL ALL PLUMBING FIXTURES, UNLESS NOTED OTHERWISE.
<br />VERIFY MOUNTING HEIGHT AND WATER CONNECTION SIZES TO ALL PLUMBING FIXTURES PRIOR TO ROUGH -IN. FURNISH
<br />CUT-OUT TEMPLATES, FOR PLUMBING FIXTURES TO BE INSTALLED IN MILLWORK, TO THE GENERAL CONTRACTOR.
<br />MAKE PROPER HOT AND COLD WATER, WASTE AND VENT PIPING CONNECTIONS TO ALL FIXTURES AND EQUIPMENT EVEN
<br />THOUGH ALL FITTINGS AND CONNECTIONS ARE NOT SHOWN.
<br />IT IS NOT THE INTENT OF THESE DRAWINGS TO COVER ALL WORK AND MATERIAL. ANY EQUIPMENT, PLUMBING FIXTURE,
<br />TRIM HARDWARE AND/OR DEVICES USUALLY UTILIZED IN THE CLASS OF WORK, THOUGH NOT SPECIFICALLY MENTIONED OR
<br />SHOWN ON THESE DRAWINGS, BUT WHICH MAY BE NECESSARY FOR THE SATISFACTORY COMPLETION OF THE WORK (AS
<br />DETERMINED BY THE ARCHITECT) SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR AS PART OF HIS TOTAL
<br />WORK.
<br />THE EQUIPMENT ROUGH -IN ITEMS AND THEIR DIMENSIONED LOCATIONS FOR ALL CONNECTIONS ARE ACCURATE TO THE
<br />BEST OF OUR KNOWLEDGE. IN SOME INSTANCES THE OWNER OR SUPPLIER MAY MAKE SUBSTITUTIONS OR THE EQUIPMENT
<br />ITEMS MAY VERY FROM WHAT IS SHOWN. THEREFORE, THESE ITEMS AND DIMENSIONS SHALL BE VERIFIED WITH THE
<br />EQUIPMENT SUPPLIER, OWNER AND/OR EQUIPMENT ROUGH -IN DRAWING. FAILURE OF THE APPROPRIATE CONTRACTOR TO
<br />VERIFY ROUGH -INS OR THEIR LOCATIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION AND/OR
<br />ADDITIONAL ROUGH -INS DIRECTLY UPON THE CONTRACTOR.
<br />CONTRACTOR SHALL SUPPLY TO THE ARCHITECT THE REQUIRED COPIES OF SHOP DRAWINGS FOR APPROVAL SO THE
<br />QUALITY OF INTENDED MATERIALS OR EQUIPMENT CAN BE REVIEWED BEFORE INSTALLATION. THERE WILL BE NO DRAW
<br />UNTIL SHOP DRAWINGS HAVE BEEN SUBMITTED AND REVIEWED BY THE ARCHITECT/ENGINEER.
<br />DO NOT SCALE THIS DRAWING. REFER TO ARCHITECTURAL FLOOR PLAN FOR BUILDING DIMENSIONS.
<br />THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT NECESSARILY SHOW ALL ELBOWS, OFFSETS, UNION, VALVES
<br />AND FITTINGS REQUIRED TO COMPLETE THE INSTALLATION OF THE WORK. THE SUBMISSION OF A PROPOSAL SHALL BE
<br />CONSTRUED AS EVIDENCE THAT THE CONTRACTOR HAS FAMILIARIZED HIMSELF WITH THE PLANS AND BUILDING SITE. CLAIMS
<br />MADE SUBSEQUENT TO THE PROPOSAL FOR MATERIALS AND LABOR BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE
<br />RECOGNIZED. IF THEY COULD HAVE BEEN FORESEEN HAD PROPER EXAMINATION BEEN MADE.
<br />VERIFY SERVICE POINTS AND METERING LOCATIONS FOR PROJECT WITH LOCAL UTILITIES AND/OR LANDLORD (DOMESTIC
<br />WATER, SANITARY SEWER, GAS, ETC.)
<br />THE CONTRACTOR SHALL COOPERATE FULLY AMONG THE TRADES.
<br />ALL ROOF PENETRATIONS FOR ROOF DRAINS AND PLUMBING, GAS AND REFRIGERANT PIPING SHALL BE MADE IN
<br />ACCORDANCE WITH ROOF SYSTEM MANUFACTURER'S GUIDELINES. COORDINATE WITH ARCHITECTURAL DETAIL AND/OR
<br />LANDLORD FOR ROOF SYSTEM USED.
<br />ALL PLUMBING VENTS IN EXTERIOR WALLS SHALL BE OFF SET A MINIMUM OF 3'-0" BEFORE ROOF PENETRATION.
<br />INSTALL 1" FIBERGLASS INSULATION WITH ALL -SERVICE JACKET ON ALL ROOF LEADERS ABOVE CEILING.
<br />PLUMBING CONTRACTOR SHALL VERIFY WITH THE LOCAL HEALTH DEPARTMENT AND/OR WATER COMPANY AS TO THE METER
<br />AND VALUING ARRANGEMENTS OF THE DOMESTIC WATER SERVICE LINE WHICH ENTERS THE BUILDING. SHOULD A BACKFLOW
<br />PREVENTER ASSEMBLY AND/OR PRESSURE REDUCING VALVE ASSEMBLY BE REQUIRED, THE PLUMBER SHALL FURNISH AND
<br />INSTALL SAME PER LOCAL AND STATE REQUIREMENTS. THE BACKFLOW ASSEMBLY SHALL BE A "WATTS" SERIES #909, OR
<br />APPROVED EQUAL MEETING ASSE STANDARDS 1013,1015, AND 1020. IF BACKFLOW PREVENTER IS REQUIRED, PROVIDE
<br />PROPERLY SIZED THERMAL EXPANSION TANK IN SUPPLY PIPING OF WATER HEATER. IF WATER PRESSURE IS 65 PSI OR
<br />ABOVE, THE PRESSURE REDUCING VALVE ASSEMBLY SHALL BE A "WATTS" SERIES #U5 SET AT 50 POUNDS, DELIVERY
<br />PRESSURE UNLESS OTHERWISE NOTED.
<br />THE POTABLE WATER SUPPLY SHALL BE PROTECTED AGAINST BACKFLOW AND SIPHONAGE BOTH NATURAL AND INDUCED.
<br />ALL EQUIPMENT CONNECTED TO THE POTABLE WATER SYSTEM BEING CAPABLE OF POLLUTING OR CONTAMINATING THE
<br />POTABLE WATER DISTRIBUTION SYSTEM OR ANY PART THEREOF BY MEANS OF A REVERSAL OF FLOW, PRESSURE DROP,
<br />PRESSURE LOSS, INDUCED VACUUM OR BY INJECTION BECAUSE OF ANY PRIMARY OR AUXILIARY PUMPING SYSTEM
<br />CONNECTED THERE TO MUST BE ISOLATED AND CONTAINED BY MEANS OF APPROVED BACKFLOW DEVICES, CHECK VALVES,
<br />AIR GAPS OR VACUUM BREAKERS. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL THESE DEVICES PER LOCAL CODE
<br />REQUIREMENTS.
<br />THE WATER PIPING SYSTEM SHALL BE FLUSHED AND STERILIZED IN ACCORDANCE WITH LOCAL REGULATIONS.
<br />THE HOT AND COLD WATER SUPPLY BRANCHES FOR ALL EQUIPMENT HAVING QUICK CLOSING VALVES OF ANY TYPE SHALL
<br />HAVE WATER HAMMER ARRESTOR INSTALLED AT THE HIGH POINT ON THE END OF EACH BRANCH.
<br />FURNISH AND INSTALL SHUTOFF OR BALL VALVE AND DIELECTRIC UNIONS ON ALL EQUIPMENT HOT AND COLD WATER LINES.
<br />PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO EQUIPMENT. COORDINATE WITH EQUIPMENT SUPPLIER FOR
<br />EXACT REQUIREMENTS.
<br />PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL A PRESSURE REDUCING VALVE ON THE INLET OF THE DISHWASHER
<br />TO REDUCE INCOMING WATER PRESSURE TO LESS THAN 20 PSI.
<br />VERIFY MOUNTING HEIGHTS OF ALL BARRIER FREE FIXTURES WITH ARCHITECTURAL PLANS.
<br />PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL COPPER INDIRECT WASTE PIPING REQUIRED FROM EQUIPMENT TO
<br />FLOOR DRAINS, OPEN RECEPTACLES OR FLOOR SINKS. PIPING SHALL COMPLY WITH STATE AND LOCAL CODES. COORDINATE
<br />WITH ALL EQUIPMENT SUPPLIERS AND SIZES AS REQUIRED BY PIECE OF EQUIPMENT SERVED. HOLD PIPING TIGHT TO WALL
<br />WHERE APPLICABLE. PROPERLY SECURE AS REQUIRED. COORDINATE WITH CASEWORK SUPPLIER FOR MAXIMUM CLEARANCE
<br />UNDER CABINETS.
<br />PROVIDE CHROME PLATED ESCUTCHEONS AT ALL WALL PENETRATIONS.
<br />PLUMBING CONTRACTOR SHALL INSTALL 4" SOIL AND WASTE PIPING WITH MINIMUM SLOPE OF 1/8" PER FOOT UNLESS
<br />OTHERWISE REQUIRED.
<br />HOLD TOP OF FLOOR DRAINS FLUSH WITH FINISHED FLOOR. SEE ARCHITECTURAL SHEETS FOR FLOOR SLOPES AND PROPER
<br />FINISHED FLOOR ELEVATION.
<br />PROVIDE TRAP PRIMERS FOR FLOOR DRAINS, FROM THE NEAREST LAVATORY, AS SHOWN ON THE PLAN AND AS REQUIRED
<br />BY LOCAL CODE. PRIMERS SHALL BE LOCATED IN A SERVICEABLE LOCATION AND INSTALLED PER MANUFACTURERS
<br />INSTALLATION INSTRUCTIONS.
<br />ALL VENT PIPE TO BE COMPATIBLE WITH STRUCTURE, MECHANICAL EQUIPMENT AND DUCTWORK, ELECTRICAL EQUIPMENT
<br />AND LIGHTING. ALL V.T.R.'S SHALL BE EXTENDED TO A MINIMUM OF 2" ABOVE PARAPET HEIGHT AND MAINTAINED 10'-0"
<br />MINIMUM FROM ALL OUTSIDE AIR INTAKES.
<br />MATERIALS, EQUIPMENT, ASSEMBLIES AND SYSTEMS SHALL MEET ALL PERTINENT REQUIREMENTS OF NATIONALLY
<br />RECOGNIZED TESTING ORGANIZATIONS SUCH AS UL, ASTM, ASSE, AWWE, AGA AND NFPA AS WELL AS THE MOST CURRENT
<br />VERSION OF THE STATE AND LOCAL CODES.
<br />ALL INSTALLED SYSTEMS, DEVICES AND RELATED ITEMS SHALL BE TESTED IN PLACE. REPLACE ANY AND ALL CONTRACTOR
<br />SUPPLIED DEFECTIVE DEVICES, ITEMS OR SYSTEMS AT CONTRACTOR'S OWN EXPENSE BEFORE COMPLETION OF PROJECT.
<br />WHERE JOB CONDITIONS REQUIRE CHANGES FROM THE CONTRACT DOCUMENTS THAT DO NOT CHANGE THE SCOPE OR
<br />NATURE OF WORK REQUIRED, THE CONTRACTOR SHALL MAKE SUCH CHANGES WITHOUT ADDITIONAL COST TO THE OWNER.
<br />NO OTHER CHANGES MAY BE MADE WITHOUT WRITTEN PERMISSION OF THE ENGINEER.
<br />ALL EQUIPMENT, FIXTURES AND MATERIALS SHALL BE NEW AND UNUSED, AND INSTALLED IN STRICT CONFORMANCE TO
<br />MANUFACTURERS RECOMMENDATIONS (U.O.N.). PROVIDE COMPLETE WITH ALL TRIM, STOPS, HANGERS, CARRIERS, SUPPORTS,
<br />ETC. INCLUDING PROVISIONS FOR BARRIER FREE USE, IF REQUIRED. WHERE FIXTURES ARE ACCESSIBLE THEY MUST COMPLY
<br />WITH ALL FEDERAL A.D.A. REGULATIONS.
<br />CONTRACTOR SHALL GUARANTEE ALL WORK FOR WHICH MATERIALS ARE FURNISHED, FABRICATED OR FIELD ERECTED, ALL
<br />FACTORY ASSEMBLED EQUIPMENT FOR WHICH NO SPECIFIC MANUFACTURERS GUARANTEE IS FURNISHED AND ALL WORK IN
<br />CONNECTION WITH THE INSTALLATION OF MANUFACTURERS GUARANTEED EQUIPMENT. THE CONTRACTOR'S GUARANTEE SHALL
<br />LAST ONE YEAR FROM THE FINAL OWNER ACCEPTANCE OF THE WORK AND SHALL APPLY TO ALL DEFECTS IN MATERIALS
<br />AND WORKMANSHIP OF ANY KIND.
<br />ALL FAUCET CONTROLS SHALL BE OPERABLE WITH ONE HAND AND NOT REQUIRE TIGHTGRASPING.
<br />ALL BARRIER FREE WATER CLOSET CONTROLS SHALL BE LOCATED ON UNIT TOWARDS WIDE SIDE OF STALL. VERIFY IF
<br />RIGHT OR LEFT SIDE LOCATION.
<br />C
<br />STATE OF FLORIDA
<br />PROFESSIONAL ENGINEER
<br />MARK E, AWMILLER
<br />PE#53973
<br />MES
<br />113.289.4700 Tampa, 33609
<br />GROUP
<br />Mark E. Awmiller, PE # 53973
<br />COA # 8304
<br />Project # 2013577
<br />THE COMMONS
<br />ON PRETfY POND
<br />38130 Pretty Pond Road
<br />Zephyrhills, FL 33540
<br />10/15/13 PERMIT SET
<br />Mark I Date
<br />Description
<br />Issue/Revision
<br />Revision
<br />Project ID
<br />13D16
<br />CAD File Name
<br />-
<br />Drawn By
<br />DKS
<br />Reviewed By
<br />MEA
<br />Plot Date:
<br />00/00/00
<br />Record Date:
<br />00/00/00
<br />Sheet Title
<br />DETAILS AND NOTES
<br />Drawing No.
<br />SCALE: 1/8"=1'-0"
<br />P-5.1
<br />5
<br />4 3
<br />2 I 1
<br />
|