My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38311 Springhead Ln
Zephyrhills
>
Building Department
>
Building Plans
>
38311 Springhead Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 2:55:07 PM
Creation date
2/19/2025 2:34:32 PM
Metadata
Fields
Template:
Building Plans
Street #
38311
Location
Springhead Ln
Contractor
D R Horton
Building Plans - Permit #
3552
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 61C906AD-2612-4E77-A048-6555F7A210C8 <br />O <br />O <br />N <br />� <br />0 <br />O 0 <br />PE^ <br />C` <br />N <br />(NI x <br />c1r) <br />a) <br />LL <br />J <br />tAp <br />O <br />0 <br />9000 REGENCY SQUARE BLVD. <br />LLI <br />SUITE 100, JACKSONVILLE, FL 32211 <br />0 <br />0 <br />1 J <br />WDiRsHOMON' <br />ELECTRIC METER Q \ <br />ELECTRIC METER 1 �— an <br />FIELD VERIFY LOCATION°' a\\'3 <br />FIELD VERIFY\.o\ J"fo Q� a\off <br />LOCATION APPLY STUCCO SCRATCH COAT AND ONE (1) w o00 <br />PRE -FORMED CONTROL 5/8" CEMENT PLASTER LAYER OF PAINT PRIOR TO INSTALLING ELECTRIC } <br />JOINT W/ STRIP LATH <br />METER U <br />12" WIDE SELF-ADHESIVE Z <br />• <br />FLASHING CENTERED UNDER W <br />CONTROL JOINT (CLEAN CAVITY TO BE FILLED 0 <br />. , MASONRY BEFORE APPLYING) WITH RIGID POLYMERIC W <br />/ ISOCYANOTE-POLYBLEN 0� >a) <br />FOAM ("GREAT STUFF" OR O <br />SIMILAR) 0 <br />O <br />APPLY A SILICON BASE f� <br />STUCCO FINISH SEALANT AT POINT THAT <br />LO <br />ELEC WIRE PENETRATES <br />5/8" CEMENT PLASTER / <br />/ 6" SELF ADHESIVE 0 <br />12" WIDE SELF-ADHESIVE \ OVER TOP & SIDES Z <br />FLASHING CENTERED UNDER i <br />CONTROL JOINT (CLEAN � \ SELF FLASHING • <br />MASONRY BEFORE APPLYING) / w <br />UNIT W <br />PROVIDE STUCCO Z <br />� PRE -FORMED CONTROL <br />SCRATCH COAT LARGER U) <br />JOINT W/ STRIP LATH , . �J. <br />THAN THE ELECTRIC �uj <br />PREMANUF. METER CAN OR METER m <br />\ DRYER VENT CAP CAN COMBO OR METER <br />(SET IN CONT. AREA TO RECEIVE CAN AND DISCONNECT Lw L.L <br />8" CMU j..,. — SEALANT) STUCCO SCRATCH COAT W W <br />SEALANT at & 1 COAT OF PAINT W/ Z <br />TOP & SIDES BACK -ROLL PRIOR TO (� V ) <br />ELECTRIC METER Z <br />INSTALLATION W C <br />Q G <br />o <br />O <br />CONTROL JOINT - HORIZ - CMU CONTROL JOINT - VERTICAL - CMU DRYER VENT (BLOCK) ELECTRICAL CONDUIT PENETRATION <br />SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. O w <br />Q <br />I-_ o <br />O <br />WOOD CONST BEYOND W <br />� FIBERCEMENT -OR-VINYL LAP � <br />1 SIDING OVER APPROVED O <br />WOOD SHEATHING 1 HOUSEWRAP INSTALLED PER U X <br />6" SELF -ADHERING WEATHER RESISTIVE FINISH COATING OVER PRIMED MFR WRITTEN SPECIFICATIONS Q <br />FLASHING BARRIER #1 ,, THREE COAT STUCCO FINISH �_ <br />EXTEND HOUSEWRAP Z <br />WEATHER RESISTIVE WEATHER RESISTIVE } (7/8" NOM) OVER GALV MTL LATH OVER NAILING FLANGE O <br />BARRIER #1 BARRIER #2 WD SHEATHING OVER 15# FELT OVER APPROVED _ <br />VINYL ANGLED a \ (RE: STRUCT) J <br />HOUSEWRAP WD SHEATHING _ W _ <br />CASING BEAD WEATHER RESISTIVE �\ �� 'X. (RE: STRUCT) I� IL •- <br />(AM66-ANGLED-1250) BARRIER #2 \ 5/16" X 7 1/4" LAP FASTEN TO WD STRUCTURAL _ Q <br />_ ' \ SIDING W/ 6 REVEAL' _ <br />MEMBER at 7" O.C. MAX MTL DRIP FLASHING W/ U <br />HEMMED EDGE SET IN CONT ° <br />2 1/2" a STARTER STRIP �8" TO �8" MID WALL - BEAD OF SEALANT Z <br />WEEP SCREED <br />8" CMU <br />CORNER BEAD / I DO NOT CAULK OR ��' �- TRIM (RE: ELEVATION) � <br />(FASTENER & 6" SELF -ADHERING SEAL OPENING k{ _ z o- (� <br />z o SPACING at 7"O.C.) FLASHING / "" N Q EXTEND 12" SELF -ADHERING <br />Q <br />. MEMBRANE FLASHING OVER —1 4 <br />m ¢ N GALVD METAL `"•—• • • <br />GALV'D METAL "Z" :::;: WINDOW FLANGE SET IN CONT O <br />J N "Z" FLASHING FLASHING 6" WIDE STRIP SELF ADHESIVE BEAD OF SEALANT Z <br />W w FLASHING, CLEAN MASONRY 2 ' <br />> _ DO NOT CAULK OR 1 1/4" X 6" SIMULATED ;". BEFORE APPLYING VINYL FLANGE CASING BEAD 0 <br />Q SEAL OPENING " INSTALLED PER MFR W PROJECT NO: <br />> WOOD TRIM MEMBER Q <br />1/2" (MIN) STUCCO FINISH WRITTEN SPECS (TYP) Z <br />/ STUCCO °' TEXTURED PER COMMUNITY X 0 <br />CMU 1 1/4" X 6" SIMULATED * ' 1/2" (MIN) STUCCO FINISH W <br />CASING BEAD SPECIFCATIONS DRAWN: <br />VINYL CASING WOOD TRIM MEMBER ` .. ' TEXTURED PER COMMUNITY MJp W <br />BEAD (AM66-1250) ' SPECIFCATIONS Q <br />1/2" (MIN) STUCCO FINISH <br />LL <br />1/2" (MIN) TEXTURED TEXTURED PER COMMUNITY SEAL GAP W/ CAULKING Q CHKD: <br />FINISH at MASONRY SPECIFCATIONS OR APPROVED SEALANT / . / TSD o <br />STUCCO CASING BEAD !/ STUCCO SIDING m o <br />O <br />RAISED BAND at BLOCK CORNER BEAD at BLOCK SIDING TO STUCCO HORIZONTAL MATERIAL TRANSITION (FRAME TO BLOCK) z <br />SCALE: N.T.S. SCALE: N.T.S. FRAME TO BLOCK SCALE: N.T.S. Q <br />SCALE: N.T.S. W 0 <br />Q � <br />z (D <br />z <br />O Q <br />SELF ADHESIVE -OR- FLUID 1 ~ Q <br />CMU WALL W/ CMU WALL W/ I- <br />1/2" (MIN) STUCCO APPLIED PAN FLASHING (CLEAN CMU LINTEL 1/2" MIN STUCCO FINISH U_ ' "STUCCO FINISH MASONRY BEFORE APPLYING) RE: STRUCTURAL) RE: STRUCTURAL LL <br />FINISH TEXTURED a (MIN) <br />PER COMMUNITY (RE: STRUCTURAL) EXTEND UP AT JAMBS 4" MIN <br />SPECIFCATIONS ti " GYP BIRD OVER PRE SHAPED STUCCO BAND tiz" GYP BIRD OVER ( ) 1z" GYP BIRD OVER J ( yz" GYP BIRD OVER ( ) Q (� <br />z PRE -SHAPED STUCCO BAND 1x2 TREATED 1x2 TREATED Z_ <br />1x2 TREATED W/ SLP TOP INSTALLED PER 1x2 TREATED W/ INSTALLED PER MFR <br />FURRING STRIPS MFR WRITTEN SPECS (RE: FURRING STRIPS FURRING STRIPS _ FURRING STRIPS _ <br />WRITTEN SPECS (RE: ELEV) PRECAST CONCRETE SILL at CMU WALL (TYP) CONTINUOUS BEAD at CMU WALL (TYP) CONTINUOUS BEAD } <br />FLANGE CASING at CMU WALL (TYP) ELEV) at CMU WALL (TYP) OF SEALANT OF SEALANT REVISIONS: <br />BEAD SELF ADHESIVE -OR- FLUID WOOD BLOCKIN SELF ADHESIVE -OR- FLUID 4 " BACKER ROD W/ SEALANT PT 1 x4 <br />APPLIED FLASHING (CLEAN APPLIED FLASHING (CLEAN a PT 1x4 SELF ADHESIVE -OR- SELF ADHESIVE -OR- 0 No. Description Date <br />MASONRY BEFORE APPLYING) MASONRY BEFORE APPLYING) VINYL FLANGE CASING BEAD FLUID APPLIED PT 2x4 FRAME FLUID APPLIED W <br />1 " GYP BIRD OVER INSTALLED PER MFR PT 2x4 FRAME ANCHOR FLASHING CLEAN ANCHOR FLASHING CLEAN O (� <br />PT 1x WOOD BUCK PT 1x WOOD BUCK �Z ( ( W <br />VINYL FLANGE CASING BEAD VINYL FLANGE CASING BEAD Z <br />SHIM AS NEEDED INSTALLED PER MFR SHIM AS NEEDED INSTALLED PER MFR 1x2 TREATED WRITTEN SPECS (TYP) SHIM AS NEEDED gMpAPS�OYNNRGYIBEFORE SHIM AS NEEDED gMpASLOyNNRGYIBEFORE _ <br />FURRING STRIPS METAL( DOOR FRAME MEWTI DOOR FRAME C� (— <br />WRITTEN SPECS (TYP) WRITTEN SPECS (TYP) CMU STEMWALL W/ <br />at CMU WALL (TYP) �8" STUCCO FINISH W W <br />BACKER ROD W/ SEALANT 48" BACKER ROD W/ SEALANT (RE: STRUCTURAL) INTERIOR EXTERIOR INTERIOR EXTERIOR X Q <br />INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR <br />W U <br />IZ CO <br />CASING BEAD at WN WINDOW HEAD at CMU WINDOW JAMB at CMU WINDOW SILL at CMU DOOR HEAD at CMU DOOR JAMB at CMU Q o ; <br />SCALE: N.T.S. SCALE: 1 1/2" = 1'-0" SCALE: 1 1/ " = 1'-0" SCALE: 1 1r " = 1'-0" SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2 " = 1'-0" z <br />A501 2 2 O <br />0 ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.