DocuSign Envelope ID. 73183216-6612-4252-8453-A9FCCD7D-984 <br />DESIGN CRITERIA AND LOADS <br />TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS <br />NOTFS 3 4 <br />I- -L I ,... o. , _ 111 <br />TABLE 7: METAL CONNECTOR SCHEDULE <br />I I77nl77K1n <br />Buildinq Code <br />Florida Building and Residential Codes , <br />7th Edition (2020) <br />Code for Design Loads <br />ANSI/ASCE 7-16 <br />ROOF LOADING' ........................ . ........... <br />Ca = 1.25 <br />TOP CHORD LIVE LOAD ................................. <br />20 PSF <br />TOP CHORD DEAD LOAD ....... ....................... <br />7 PSF (TILE = 15 PSF) <br />BOTTOM CHORD LIVE LOAD <br />ATTICS WITH LIMITED STORAGE .............. <br />20 PSF <br />ATTICS WITHOUT STORAGE.... .... <br />...... 10 PSF <br />(NON -CONCURRENT) <br />BOTTOM CHORD DEAD LOAD........ ............. <br />5 PSF <br />WIND LOADING ^3 .......... ......................... <br />Cd 1.60 <br />ASCE 7-16, 3S GUST ......... .............................. <br />139 MPH <br />BASIC WIND SPEED <br />EXPOSURE CATEGORY... -_ -- __- ........ <br />C <br />BUILDING CATEGORY .............. ............. <br />_.II <br />ENCLOSURE CLASSIFICATION ...................... <br />ENCLOSED <br />INTERNAL PRESSURE COEFF........................0 <br />18 <br />C&C DESIGN PRESSURES ... .. ..._........(SEE <br />TABLE 1) <br />FLOOR LOADING .... ............... ................ <br />......... ..Cd = 1.00 <br />TOP CHORD LIVE LOAD..................................40 <br />PSF <br />TOP CHORD DEAD LOAD.. ....... ........... <br />......... 10 PSF (TILE = 17 PSF) <br />BOTTOM CHORD LIVE LOAD .......................... <br />0 PSF <br />BOTTOM CHORD DEAD LOAD........................5 <br />PSF <br />SPECIAL FLOOR (GAME ROOM) LOADING... Cd = 1.00 <br />TOP CHORD LIVE LOAD.... .............................. <br />60 PSF <br />TOP CHORD DEAD LOAD ........... .................10 <br />PSF <br />BOTTOM CHORD LIVE LOAD...... <br />..........0 PSF <br />BOTTOM CHORD DEAD LOAD . <br />_ _ _ _ _ 5 PSF <br />MAXIMUM FLOOR TRUSS SPACING..............16" <br />O.C. <br />DEFLECTION CRITERIA <br />LL / 240 <br />ROOF TRUSSES ............................................. <br />TL / 180 <br />TL MAX 1" UP TO 40' SPAN <br />LL / 480 <br />TL / 360 <br />OPEN WEB FLOOR TRUSSES ....................... <br />LL / 480 <br />TL / 240 <br />WOOD I JOISTS .............................................. <br />TL MAX <br />ILL /360 <br />BEAMS' _ .................................. _............... <br />......TL / 240 <br />NOTES: <br />1 PORCH BEAMS AND BEAMS SUPPORTING EXTERIOR WALL <br />ABOVE SHALL NOT EXCEED 3/d" DEFLECTION <br />2. MAX 16" O.C. FLOOR TRUSS SPACING BELOW GAME ROOM <br />3. ROOF TRUSS WIND DESIGN METHOD SHALL BE MWFRS <br />(DIRECTIONAL -OR- ALL HEIGHT) C-C HYBRID <br />TABLE 1: COMPONENT AND <br />CLADDING DESIGN PRESSURES <br />WINDOWS AND DOORS <br />EFFECTIVE <br />WIND AREA <br />ZONE DESIGNATION <br />IZ - Interior Zone (psf) <br />EZ - End Zone (psf) <br />0-20 ft2 <br />+28.54 -30.96 <br />+28.54 <br />-38.22 <br />21 - 50 ft2 <br />1 +27.17 -29.59 <br />+27.17 <br />-35.47 <br />51 - 100 ft2 <br />+25.52 -27.94 <br />+25.52 <br />-32.17 <br />- 2 <br />101 200 ft <br />-26. 7 <br />24.25 6 <br />24.2 5 <br />29. 4 <br />6 <br />SOFFIT MAX PRESSURE (psf) <br />+28.6 <br />-38.3 <br />GARAGE DOOR PRESSURE <br />+21.7 <br />-24.6 <br />I THIS STRUCTURE IS LOCATED IN THE WIND BORNE DEBRIS REGION <br />AND HAS BEEN DESIGNED AS AN ENCLOSED STRUCTURE. AS SUCH, <br />THE BUILDER MUST SUPPLY OPENING PROTECTION IN ACCORDANCE ! <br />WITH FBC 6TH ED. 2017 SECTION 1609.1.2 AND/OR FRC 6TH ED. 2017 j <br />SECTION 301.2.1.2 AND LOCAL BUILDING JURISDICTION. <br />END ZONE KEY MAP <br />END ZONE: END ZONES SHALL BE TAKEN <br />AS THE 1ST 4.0' PER FIGURE R301.2 (7) <br />1 ST FLOOR cnP) <br />END ZONE <br />DESIGNATION <br />O <br />STUCCO AND DIRECTLY <br />MIN 1%2" 32/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICALLY OR (%6' 24/16 <br />ADHERED STONE <br />INSTALLED HORIZONTALLY) W/ 8d COMMON: 6" O.C. AT PANEL EDGES, 12" O.C. IN THE <br />� N <br />(NOTE 6) <br />FIELD. 2x4 BLOCKING IS RECOMMENDED AT UNSUPPORTED PANEL EDGES. <br />ww� <br />v J z <br />ALL OTHER VENEER <br />MIN 1%/ '32/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICAL OR HORIZONTAL <br />(NOTE 8) <br />W/ 8d COMMON: 6" O.C. EDGES AND FIELD (UNBLOCKED HORIZONTAL PANEL EDGES); <br />6" O.C. AT PANEL EDGES, 6" O.C. IN FIELD (BLOCKED HORIZONTAL PANEL EDGES) <br />x c9 rn <br />TILE AND METAL ROOF <br />MIN 15/32" 32/16 SPAN RATED PLYWOOD INSTALLED WITH LONG DIMENSION <br />Z .6PERPENDICULAR <br />(NOTE 7) <br />TO SUPPORTS W/ RSRS-01 NAILS: 4" O.C. AT PANEL EDGES AND <br />o i - <br />6" O.C. IN THE FIELD <br />w0 w � <br />MIN Z116" 24/16 SPAN RATED OSB OR PLYWOOD INSTALLED WITH LONG DIMENSION <br />O = 0 <br />w cn <br />SHINGLE ROOF <br />PERPENDICULAR TO SUPPORTS W/ RSRS-01 NAILS: 6" O.C. AT PANEL EDGES, 6" <br />O.C. IN THE FIELD. <br />FLOOR DECK SHEATHING: <br />2Y32" T&G OSB OR PLYWOOD W/ 10d COMMON: 6" O.0 AT PANEL EDGES, 12" O.C. IN THE <br />(NOTE 5) <br />FIELD. <br />MIN 3/" OSB OR PLYWOOD OR CDX INSTALLED PERPENDICULAR TO SUPPORTS W/ 8d <br />PORCH CEILING BOARD SHEATHING <br />COMMON: 3" O C. AT PANEL EDGES 12" O.C. IN THE FIELD OR MIN %" EXTERIOR GYPSUM <br />CEILING BOARD, FASTEN w/ 5d x 1 /" COOLER NAIL OR NO.6 x 1 /" LONG SCREWS @ <br />4" O.C. EDGES, 8" O.C. FIELD <br />NOTES: <br />1. FOR SHEATHING THICKNESS GREATER THAN 1V32" CATEGORY, USE RSRS-03 NAILS. <br />2. COMMON NAILS IN WALL SHEATHING MAY BE SUBSTITUTED W/ 8d GALVANIZED BOX NAILS. <br />3. ZIP WALL SHEATHING IS AN ACCEPTABLE ALTERNATE FOR APA RATED WOOD STRUCTURAL PANEL. <br />4. ALL WOOD STRUCTURAL PANEL SHALL CONFORM TO THE MOST CURRENT APPLICABLE SPECIFICATION AND SUPPLEMENTS OF <br />CURRENT APPROVED APA.MANF. SPECIFICATIONS, <br />5. FLOOR FASTENERS ARE MINIMUM REQUIRED FOR DIAPHRAGM DESIGN. FOR INCREASED FLOOR PERFORMANCE AND TO <br />REDUCE SQUEAKING, RSRS-01 NAILS OR 8d SCREW NAILS ARE RECOMMENDED. <br />6. 1%2" 32/16 SPAN RATED OSB OR PLYWOOD WITH BLOCKED PANEL EDGES IS AN APA RECOMMENDATION PER APA TECHNICAL <br />BULLETIN Q370 WHEN STUCCO LATH IS ATTACHED DIRECTLY TO OSB OR PLYWOOD.. SHOULD BUILDER SPECIFICATIONS ALLOW, MIN <br />7 „ <br />D HORIZONTALLY R VERTI ALLY PER FLEXIBLE VENEER WALL <br />STRUCTURAL REQUIREMENTS ARE /6 24/16 SPAN RATING INSTALLED O C <br />SPECIFICATIONS. INCLUDES FULL AND PARTIAL HEIGHT VENEER APPLICATIONS. <br />7. 1V32" PLYWOOD IS A WARRANTY LIMITATION COMMON TO TILE MANUFACTURER'S MINIMUM RECOMMENDATIONS. SHOULD WARRANTY <br />AND INSTALLATION REQUIREMENTS ALLOW, 1V32" APA RATED OSB OR EQUAL MAY BE USED TO SUPPORT TILE ROOF. <br />8. WOOD STRUCTURAL PANEL MAY BE INSTALLED VERTICALLY OR HORIZONTALLY W/ UNBLOCKED HORIZONTAL PANEL EDGES. <br />9. ROOF DECK SHEATHING HAS BEEN ENGINEERED TO RESIST ASCE 7-16 WIND LOADS IN ACCORDANCE WITH FRC R301.2.2.1 <br />TABLE 4: NAIL SIZE LEGEND TABLE 5: FASTENERS IN <br />NOTES 1, 2, 3, 411 PRESSURE TREATED LUMBER <br />DIAMETER <br />LENGTH <br />8d COMMON <br />0.131" <br />2-'/2" <br />RSRS-01 <br />0.113" <br />2-Y8" <br />RSRS-03 <br />0.131" <br />2-'/2' <br />10d <br />0.131" <br />3" <br />10d COMMON <br />0.148" <br />3" <br />12d COMMON <br />0.148" <br />3 - % <br />16d SINKER <br />0.148" <br />3-'/:' <br />16d COMMON <br />0.162" <br />3-Y2' <br />PRESERVATIVE <br />FASTENER TYPE <br />ACZA <br />STANDARD CARBON STEEL <br />SODIUM BORATE (NOTE 1) <br />STAINLESS CONNECTORS AND <br />FASTENERS REQUIRED. <br />CONNECTORS MUST HAVE <br />Z-MAX, G120 OR TRIPLE ZINC <br />ALL OTHER PT <br />COATED FINISH. <br />(INCLUDING ACQ & MCQ) <br />ALL FASTENERS MUST BE HOT <br />DIPPED GALVANIZED. <br />NOTES: <br />1. INSTALL 10d NAILS UNLESS OTHERWISE SPECIFIED. <br />NOTES: <br />2. COMMON WIRE NAILS AND THREADED HARDENED STEEL NAILS <br />1. SILL PLATES W/ SODIUM BORATE TREATMENTS BEARING ON <br />SHALL CONFORM TO THE NOMINAL SIZES SPECIFIED IN ASTM <br />CONCRETE OVER VAPOR BARRIER ARE NOT DIRECTLY <br />F1667. NOMINAL DIAMETER SIZES APPLY TO FASTENERS <br />EXPOSED TO EARTH OR WEATHER AND HAVE BEEN PROVEN <br />BEFORE APPLICATION OF PROTECTIVE COATING. <br />TO BE NON -CORROSIVE TO CARBON STEEL FASTENERS. <br />3. WHEN A BORED HOLE IS REQUIRED TO PREVENT SPLITTING OF <br />A WOOD DUE TO FASTENER PENETRATION, THE BORED HOLE <br />SHALL NOT EXCEED 75% OF THE NAIL OR SPIKE DIAMETER. <br />4. THE NOMINAL DIAMETER AND LENGTH OF TYPICAL FASTENERS <br />SPECIFIED FOR THIS PROJECT ARE AS LISTED IN TABLE 4. <br />CONCRETE AND FOUNDATION NOTES <br />1. CONCRETE COMPRESSIVE STRENGTH FOR FOOTINGS= 2,500 PSI AT 28 DAYS (UNO). <br />2. CONCRETE COMPRESSIVE STRENGTH FOR SLAB = 2,500 PSI AT 28 DAYS (UNO). <br />3. ALL REINFORCING STEEL #3 AND BIGGER SHALL BE ASTM A615 GRADE 40 DEFORMED BARS (UNO). <br />4. ALL REINFORCING STEEL SHALL HAVE 90 DEGREE BEND AT CORNERS WITH A 24" LAP. 24" LONG #4 BAR IS RECOMMENDED TO BE <br />INSTALLED AT ALL REENTRANT CORNERS. <br />5. FIBERMESH IS AN ACCEPTABLE ALTERNATIVE AND SHALL NOT REQUIRE WWF. FIBER LENGTHS SHALL BE'/2' TO 2" IN LENGTH. <br />DOSAGE AMOUNTS SHALL RANGE FROM 0.75 TO 1.5 POUNDS PER CUBIC YARD IN ACCORDANCE WITH THE MANUFACTURER'S <br />RECOMMENDATIONS. SYNTHETIC FIBERS SHALL COMPLY WITH ASTM C1116. THE MANUFACTURER OR SUPPLIER SHALL PROVIDE <br />CERTIFICATION OF COMPLIANCE WHEN REQUESTED BY THE BUILDING OFFICIAL. <br />6. MASONRY STEMWALL AND MONOLITHIC FOOTING ARE INTERCHANGEABLE. <br />7. EARTH AND EARTH FILL SUPPORTING SLABS ON GRADE IS ASSUMED TO HAVE A MINIMUM BEARING CAPACITY OF 2,000 PSF IN <br />ACCORDANCE WITH TABLE R401.4.1, AND SHALL BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS. <br />COMPACT THE FILL IN 12" LIFTS TO AT LEAST 95% OF MODIFIED PROCTOR MAXIMUM DRY DENSITY. IT IS THE OWNER'S OR <br />CONTRACTOR'S RESPONSIBILITY TO CONFIRM THESE ASSUMPTIONS. <br />8. CONCRETE FLOOR SLABS ON GRADE SHALL BE INSTALLED OVER A MINIMUM 6 MIL POLYETHYLENE VAPOR RETARDER WITH <br />JOINTS LAPPED 6" AND SEALED OVER CLEAN, COMPACTED EARTH OR FILL WITH CODE APPROVED PROVISIONS FOR <br />PREVENTION OF SUBTERRANEAN TERMITES. <br />9. STEMWALLS OVER 4 COURSES TALL REQUIRE SPECIAL ATTENTION TO BRACING DURING CONSTRUCTION. CONTACT ENGINEER <br />OF RECORD IF THIS CONDITION EXISTS. <br />10, TO CONTROL CRACKING, CUT 1" SAWCUTS IN THE SLAB IN A 15'x15' GRID WITHIN 12 HOURS OF CONCRETE PLACEMENT. <br />CONTACT FOR FOR ALTERNATIVE METHODS. CONTROL JOINTS ARE NOT REQUIRED WHEN WWF OR FIBERMESH ARE INCLUDED <br />WITH CONCRETE WORK. <br />11. DO NOT SCALE FOOTING DIMENSIONS AND LOCATIONS FROM THE FOUNDATION PLAN. DO NOT DETERMINE FOOTING LOCATION <br />FROM ARCHITECTURAL PLANS OR FRAMING PLAN. IF FOOTING SIZE OR LOCATION IS NOT DETERMINATE FROM USE OF <br />FOUNDATION PLAN ALONE, CONTACT THE ENGINEER OF RECORD. <br />PRE-ENGINEERED TRUSSES & I -JOISTS <br />1. ROOF TRUSS TOP CHORDS SHALL HAVE A MINIMUM SPECIFIC GRAVITY OF 0.49 (SYP SPECIES OR BETTER). <br />2. ROOF OR FLOOR TRUSSES FABRICATED TO ACHIEVE THE ROOF PLANES DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE <br />DESIGNED UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER. ENGINEERING SHOP DRAWINGS <br />RECORD FOR APPROVAL PRIOR TO <br />WITH AN <br />SHALL BE PREPARED IN ACCORDANCEI/TPI AND SUBMITTED TO THE ENGINEER OF S <br />FABRICATION. DESIGN CRITERIA IS LOCATED ON SHEET ST-1 OF THE PLAN SET, TEMPORARY BRACING SHALL BE THE <br />RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE LEFT IN PLACE AFTER CONSTRUCTION IS COMPLETE. <br />3. TRUSSES OR I -JOISTS SHALL BE DESIGNED TO MATCH THE ORIENTATION, SPAN DIRECTION, SPACING, BEARING LOCATION AND <br />NAMING CONVENTION OF THE LAYOUT SHOWN HERE. <br />4. THE TRUSS ENGINEER SHALL PROVIDE ALL TRUSS TO TRUSS CONNECTION DESIGN AND SPECIFICATIONS AND SUBMIT THEM <br />UNDER SIGN AND SEAL WITH THE TRUSS SHOP DRAWINGS. <br />5. TRUSS UPLIFTS HAVE BEEN CALCULATED BY THE ENGINEER OF RECORD AND TAKEN INTO CONSIDERATION DURING THE DESIGN <br />OF THE UPLIFT RESTRAINT SYSTEM FOR THIS STRUCTURE, AS SUCH, THE REPORTED UPLIFTS ON THE TRUSS SHOP DRAWINGS <br />MAY BE DISREGARDED. <br />6. I -JOISTS FABRICATED TO ACHIEVE THE FLOOR PLANS DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE DESIGNED AND <br />SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. SEE DESIGN CRITERIA, <br />THIS SHEET. <br />r4U I CA L, .5, 4 <br />USP & SIMPSON CONNECTORS IN CORRESPONDING ROWS BELOW ARE EQUAL <br />ALTERNATIVES AND MAY BE CONSIDERED INTERCHANGEABLE <br />SIMPSON <br />SIMPSON FASTENERS <br />MITEK <br />USP FASTENERS <br />(8)'/< X 1 %" SIDS SCREWS <br />(8)%' x 11/2' WS15-GC <br />DTT2Z <br />IN STUDY2" 0 X 4'/2" <br />WOOD SCREWS IN STUD <br />(NOTE 2) <br />EMBED EPDXY OR <br />DTB-TZ <br />1/2 0 x 4%" EMBED EPDXY <br />SCREW ANCHOR <br />OR SCREW ANCHOR <br />(18)0.162"x2'/z"IN <br />(18)0.162"x2'/z"IN <br />HTT4 <br />STUD/BEAM/TRUSS <br />STUD/BEAM/TRUSS <br />(NOTE 2) <br />fie" 0 x 6" EMBED ANCHOR <br />HTT45 <br />fie" 0 x 6" EMBED ANCHOR <br />IN CONCRETE <br />IN CONCRETE <br />(26) 0.162" x 2 '/s" IN <br />(26) 0.162" x 2 1/2" IN <br />HTT5 <br />STUD/BEAM/TRUSS <br />STUD/BEAM/TRUSS <br />(NOTE 2) <br />%" 0 x 6" EMBED ANCHOR <br />HTT45 <br />%" 0 x 6" EMBED ANCHOR <br />IN CONCRETE <br />IN CONCRETE <br />(20)'/<" x 3" SDS SCREWS <br />(24) 3" WS IN STUD <br />HDQ8-SDS3 <br />IN STUD GROUP <br />PHD8 <br />GROUP'e" 0 x 12" EMBED <br />'8" 0 x 12" EMBED <br />ANCHOR IN CONCRETE <br />ANCHOR IN CONCRETE <br />(7) 10d x 1 '/2" IN TRUSS <br />(7) 10d x 1 %" IN TRUSS <br />META12 <br />4" WET EMBED IN <br />HTA16-18 <br />4" WET EMBED IN <br />GROUTED BLOCK WALL <br />GROUTED BLOCK WALL <br />(8) 10d x 1 ''/2" IN TRUSS <br />(9) 10d x 1 '/V IN TRUSS <br />META20 <br />4" WET EMBED IN <br />HTA20-18 <br />4" WET EMBED IN <br />GROUTED BLOCK WALL <br />GROUTED BLOCK WALL <br />ABU44 <br />(12) 16d COMMON NAILS <br />PAU44 <br />(12) 16d COMMON NAILS <br />(NOTE6 <br />4 " 7" Y <br />8 0 x EMBED EPDXY <br />4 " x 7" EMBED EPDXY <br />8 0 <br />(12) 16d COMMON NAILS <br />(12) 16d COMMON NAILS <br />ABU66 <br />%" 0 x 7" EMBED EPDXY <br />PAU66 <br />§8 0 x 7" EMBED EPDXY <br />(NOTE 6) <br />(12" EMBED AT GARAGE <br />(12" EMBED AT GARAGE <br />DOOR RETURNS) <br />DOOR RETURNS) <br />(14) 16d COMMON IN <br />HD4HD488, <br />(14) 16d COMMON IN <br />C 8, <br />HC48 <br />HEADER <br />HEADER <br />HU <br />HUC28-2 <br />(6) 10d COMMON IN BEAM <br />HD28-2 <br />HD28 -2F <br />(6) 10d COMMON IN BEAM <br />HU410, <br />(18) 16d COMMON IN <br />HD410, <br />(18) 16d COMMON IN <br />HUC410, <br />HEADER <br />HD4101F, <br />HEADER <br />HU210-2, <br />(10) 10d COMMON IN <br />HD210-2, <br />(10) 10d COMMON IN <br />HUC210-2 <br />BEAM <br />HD210-21F <br />BEAM <br />(22) 16d COMMON IN <br />(22) 16d COMMON IN <br />HUC212-2 <br />HEADER <br />HD212-21F <br />HEADER <br />10 10d COMMON IN BEAM <br />10 10d COMMON IN BEAM <br />(4)%" x 1 Y2" SIDS SCREW <br />(4) %" x 11/2' WS15 SCREWS <br />IN TRUSS/RAFTER <br />IN TRUSS/ RAFTER <br />HGA10KT <br />(4)%" x 3" SIDS SCREWS <br />HGA10 <br />(4) '/:' x 3" WS3 SCREWS <br />IN TOP PLATE <br />IN TOP PLATE <br />(4) SDS'/:' x 1 '/2' SCREWS <br />(4) %" x 1'/2" WS15 SCREWS <br />HGAMIOKT <br />IN TRUSS/RAFTER <br />HGAMIOKT <br />IN TRUSS/ RAFTER <br />(4) /. x 13 WEDGE BOLT <br />(4) %" x 23/+" TITEN SCREWS <br />L_ <br />IN MASONRY <br />OR EQUIVALENT IN <br />I <br />I MASONRY <br />SIMPSON <br />SIMPSON <br />FASTENERS <br />MITEK <br />USP FASTENERS <br />(9) 10d COMMON <br />(9) 10d <br />CS18 <br />EACH END <br />CS20 <br />COMMON <br />EACH END <br />MTS12 <br />(7) 10d x 1 '/2" <br />MTW12 <br />(7) 10d x 1 'Y2" <br />EACH END <br />EACH END <br />MSTA24 <br />(9) 10d COMMON <br />MSTA24 <br />(9) 10d COMMON <br />EACH END <br />EACH END <br />MSTA36 <br />13 10d COMMON <br />( ) <br />MSTA36 <br />(13) 10d COMMON <br />EACH END <br />EACH END <br />(7) 10d COMMON IN <br />(7) 10d COMMON IN <br />MSTAM36 <br />WOOD FRAMING <br />MSTAM36 <br />WOOD FRAMING <br />(4) %" x 2 %" TITEN <br />(5) %" x 2 %" TAPCON IN <br />SCREWS IN MASONRY <br />MASONRY <br />(11)10dx1%"IN <br />(11) 10d x 1 1/2" IN <br />HTS20 <br />TRUSS/RAFTER <br />HTW20 <br />TRUSS/RAFTER <br />(11) 10d x 1 1/2" IN <br />(11) 10d x 1 '/z" IN <br />STUD <br />STUD <br />(12)10dx1'/z"IN <br />(8)10dx1'/z"IN <br />TRUSS/RAFTER <br />TRUSS/RAFTER <br />HTSM20 <br />1210dx1/zIN <br />HTWM20 <br />+ <br />4 x 3" WEDGE BOLT <br />O /,„ <br />STUD <br />OR EQUIVALENT IN STUD <br />(5)8dx1%"IN <br />(5) 8d x 11/2" IN <br />H2.5T/ <br />TRUSS <br />RT7/ <br />TRUSS <br />HA8 <br />(5) 8d x 1'/2' IN <br />RT7AT <br />(5) 8d x 1'/s" IN <br />TOP PLATE <br />TOP PLATE <br />(5) 10d x 11/2" IN <br />(5) 10d x 1'/z" IN <br />TRUSS <br />TRUSS <br />H8 <br />(5) 10d x 1 Y7" IN <br />RT8A <br />(5) 10d x 11/z" IN <br />TOP PLATE <br />TOP PLATE <br />(16) 1bd UUMMUN IN <br />(16) 10d COMMON TO <br />TRUSS/RAFTER <br />TRUSS/RAFTER <br />LGT2 <br />(7) Y:' x 2 %" TITEN <br />LUGT2 <br />(5) '0" x 3" WEDGE BOLT <br />SCREWS IN MASONRY <br />OR EQUIVALENT <br />(26) 16d SINKER <br />(28) 16d SINKER IN WALL <br />LGT3 <br />IN WALL FRAMING <br />LUGT3 <br />FRAMING <br />(12) SIDS %" x 2 Y2' <br />(12) WS25 %" x 2 ''/z" <br />IN TRUSS <br />IN TRUSS <br />SDWC14500, SDWC15600 <br />NO USP EQUIVALENT <br />NOTES: <br />1. REFER TO FRAMING NOTES THIS SHEET FOR ACRYLIC -TIE INSTALLATION SPECIFICATIONS. <br />2. PRODUCTS SELECTED USING SIMPSON 2019-2020 CATALOG. PRODUCTS MAY BE SUBSTITUTED WITH EQUAL OR BETTER APPROVED ALTERNATES <br />3. REFER TO SIMPSON CATALOG FOR ADDITIONAL INSTALLATION INSTRUCTIONS. <br />4. IF CONNECTOR IS NOT LISTED ABOVE, CONTACT FOR FOR SPECIFIC FASTENING REQUIREMENTS. <br />5. POSITIVE PLACEMENT GUN NAILS, 2 %" LONG, WITH EQUIVALENT DIAMETER TO COMMON NAILS SPECIFIED ABOVE MAY BE USED FOR <br />ABU POST BASE ANCHORS, CS16, AND MSTA FLAT STRAPS. <br />6. MASONRY APPLICATION REQUIRE EQUIVALENT NUMBER OF TITEN ANCHORS IN LIEU OF 16d NAILS TO HDR CONNECTION. CMU REQUIRES <br />'/:' 0 x 2 W TITENS ILO 16d. CONCRETE REQUIRES EQUIVALENT NUMBER OF '/:' 0 x 1 3/." TITENS ILO 16d. <br />MASONRY NOTES <br />1. ALL MASONRY UNITS SHALL HAVE fm = 1,500 PSI AND SHALL ERECTED IN RUNNING BOND WITH TYPE M OR S MORTAR OVER FULL <br />BED. <br />2. SHOULD LIMITED AREAS OF STACK BOND MASONRY EXIST, EVERY OTHER COURSE SHALL BE EQUIPPED w/ 9 GAUGE LADDER <br />TYPE HORIZONTAL JOINT REINFORCEMENT <br />ALL GROUT TO MIXED PER ASTM C476 STANDARDS AND INSTALLED TO COMPLY WITH FBC R606.3.5. fc = 3 3 000 PSI. , <br />4. VERTICAL WALL REINFORCING TO BE ASTM A615 GRADE 60 REBAR. <br />5. LAPS BETWEEN VERTICAL REINFORCING AND DOWELS TO BE 30". <br />6. VERTICAL REINFORCING TO HAVE 10" STANDARD HOOK INTO BOND BEAM. DOWEL TO HAVE 10" STANDARD HOOK INTO FOOTING <br />7. PRE -CAST MASONRY LINTELS: SEE "TYPICAL PRE -CAST LINTEL OPTIONS" DETAIL ON STRUCTURAL DETAIL SHEET. <br />8. PROVIDE MOISTURE BARRIER FOR ALL UNTREATED LUMBER IN CONTACT WITH MASONRY OR CONCRETE. <br />OR "OR" SHALL MEAN THAT EITHER OPTION PROVIDED IS AN EQUAL <br />ALTERNATIVE FOR THE APPLICATION SHOWN <br />UNO UNLESS NOTED OTHERWISE ON PLAN OR DETAIL <br />FOR ENGINEER OF RECORD <br />A HW Y <br />EW <br />C- C A <br />0 <br />OSB <br />WSP <br />ORIENTED STRAND BOARD <br />WOOD STRUCTURAL PANEL <br />SOUTHERN YELLOW PINE <br />O <br />LID <br />APEX <br />0 <br />0 <br />SYP <br />SPF <br />SPRUCE -PINE -FUR <br />N <br />CONT <br />CONTINUOUS <br />0 <br />Q) <br />O.C. <br />ON CENTER <br />It <br />x <br />a) <br />LSL <br />1.55E TIMBERSTRAND LSL ENGINEERED LUMBER, 1 3/4" WIDE, UNO. <br />(3 %" WIDE LSL BEAMS ARE EQUIVALENT TO 2-PLY 1 -%" BEAM) <br />+ <br />LVL <br />2.0E MICROLLAM LVL ENGINEERED LUMBER, 1 3/" WIDE <br />PSL <br />SYS 42 <br />2.0E PARRALLAM PSL ENGINEERED LUMBER, 3 '/2' WIDE, UNO. <br />PROPERLY RATED OPEN WEB HEADER <br />M <br />INTERIOR ROOF LOAD BEARING WALL, SPECIFICATIONS <br />OUTLINED ON TYPICAL WALL SECTIONS, DETAIL SHEETS <br />LL <br />tds <br />W <br />INTERIOR BEARING WALL WITH NO UPLIFT. NO UPLIFT ANCHORS REQUIRED. MINIMUM <br />J <br />J <br />iQ <br />a)BOTTOM <br />PLATE ANCHORAGE IS 1/2" ANCHOR @ 8'-0" O.C. (UNO ON FRAMING PLAN OR <br />true design studies <br />SW SPECIFICATIONS) <br />z <br />O <br />STRUCTURAL WOOD BEAM <br />(A <br />- <br />Y <br />9000 REGENCY SQUARE BLVD. <br />STUD COLUMN KEYNOTE <br />Q <br />SUITE 100, JACKSONVILLE, FL 32211 <br />NUMBER OF SDWC15600 CONNECTING TOP PLATE TO STUDS. <br />_O <br />O <br />NUMBER OF STUDS BELOW BEAM/GIRDER TRUSS. STUDS <br />O <br />2 <br />1 2 STUDS <br />(D w <br />0 <br />2 <br />ANCHOR <br />TO MATCH WALL FRAMING SIZE AND GRADE, LINO. I: <br />W c3' <br />ADDITIONAL CLARITY FOR THE LOCATION OF THE STUD COLUMN F- <br />Q) <br />i� <br />HIROHOMN <br />0) <br />BOTTOM OF STUD COLUMN CONNECTION � <br />1ST LEVEL STUD COLUMN: HOLDDOWN REQUIRED AT BASE OF COLUMN s <br />2ND LEVEL STUD COLUMN: STRAPPING REQUIRED FROM 2ND LEVEL J <br />COLUMN TO 1ST LEVEL STUDS/HEADER/BEAM. co <br />"ANCHOR" REQUIRES BOTTOM PLATE ANCHOR WITHIN 3" OF STUD COLUMN w <br />NUMBER OF SDWC15450 CONNECTING STUDS TO BOTTOM PLATE Q <br />HEADER STRAPPING KEYNOTE <br />NUMBER OF STRAPS CONNECTING HEADER TO JACK STUD (n <br />1 MSTA24 TYPE OF STRAP CONNECTING HEADER TO JACK STUD U <br />1 DTT2Z Z <br />KING/JACK GROUP BOTTOM CONNECTION w <br />1ST LEVEL STUD GROUP: HOLDDOWN REQUIRED AT BASE OF STUD GROUP 0 <br />2ND LEVEL STUD COLUMN: STRAPPING REQUIRED FROM 2ND LEVEL STUD w <br />GROUP TO 1ST LEVEL STUDS/HEADER/BEAM. w <br />NUMBER OF HOLDDOWNS/STRAPS AT BASE OF KING/JACK GROUP O <br />O <br />NON -BEARING HEADER FRAMING KEYNOTE <br />NO HDR - # NUMBER OF KING STUDS EACH SIDE OF OPENING <br />UA <br />HEADER MAY BE FRAMED AS NON BEARING HEADER DUE TO LIGHTLY <br />LOADED CONDITIONS ABOVE 0 U) <br />#2 SYP HEADER FRAMING KEYNOTE z W <br />U <br />(2)2, 10-1 / 2 NUMBER OF KING STUDS EACH SIDE OF OPENING (A Uj <br />W <br />NUMBER OF JACK STUDS EACH SIDE OF OPENING z Z W <br />DEPTH OF LOAD -BEARING #2 SYP HEADER O <br />NUMBER OF PLIES IN HEADER mLLJ U) <br />Ix <br />ENGINEERED LUMBER HEADER FRAMING KEYNOTE W Q <br />NUMBER OF KING STUDS EACH SIDE OF OPENING W <br />Z <br />NUMBER OF JACK STUDS EACH SIDE OF OPENING Z > Q Q <br />HEADER MATERIAL (LSL, LVL, PSL, OR SYS42) W W 0 <br />Uj W <br />DEPTH OF LOAD -BEARING EWP HEADER < Q W g <br />NUMBER OF PLIES IN HEADER (1 34" WIDE UNO) W <br />HEADER FRAMING i x <br />IL U <br />1. ALL HEADER JACK AND KING STU DS SHALL BE FASTENED TO EACH OTHER WITH (2) ROWS 10d @ 8" O.C. z <br />STAGGERED. z <br />2. NON BEARING HEADERS: DUE TO LIGHTLY LOADED CONDITIONS, 49" OR LESS CLEAR -OPENINGS IN AN � O <br />EXTERIOR WALL DO NOT REQUIRE LOAD BEARING HEADER, SEE PLAN. Q 0 <br />3. FASTEN ALL MULTI -PLY HEADERS TOGETHER WITH (2) ROWS 10d @ 8" O.C., STAGGERED ALONG EACH EDGE. 0f w <br />4. FASTEN ALL HEADERS TO KING STUDS WITH (3)8d TOE NAILS O Z <br />5. IF HEADER NOT SPECIFIED, CONTACT ENGINEER OF RECORD. a <br />6. UNO ON PLAN, MIN (1) SDWC15600 TOP PLT TO KING STUD AND (1) SDWC15450 KING STUD TO BOTTOM PLATE O EE <br />d <br />CONNECTION REQUIRED EACH SIDE OF OPENING (NO CONNECTION REQUIRED FOR OPENINGS AT FIRST <br />FLOOR HEADER WHEN A 2ND LEVEL FLOOR SYSTEM IS ABOVE. U LL <br />7. TOP PLATE TO HEADER CONNECTION PER ONE OF THE FOLLOWING (NO CONNECTION REQUIRED FOR Q <br />OPENINGS 39" OR LESS, OR AT FIRST FLOOR HEADERS WHEN A 2ND LEVEL FLOOR SYSTEM IS ABOVE: 0 J <br />• SDWC15600 @ MAX 32" O.C. AS SHOWN, "ALTERNATE SECTION (HEADERS),ST-5 O Abbott Park U <br />• SPH w/ (12) 10d x 1- Y2" @ 16" O.C. OR <br />• DSP w/ (14) 10d x 1- Y2' @ 16" O.C. OR LL LOT 003-04-1 C <br />• FASTEN TRUSS DIRECTLY TO HEADER w/ MTS OR HTS w/ (14) 10d x 1-%" (OR EQUAL APPROVED BY EOR). Q w <br />8. CRIPPLE BLOCKS BELOW LOAD -BEARING HEADERS MAY BE FRAMED AT 24" O C. F- <br />C) a <br />z z <br />O <br />FRAMING NOTES O PROJECT NO LU <br />1. SIMPSON ACRYLIC -TIE ADHESIVE OR EQUAL SHALL BE USED IN ALL DRILLED AND EPDXIED ANCHOR APPLICATIONS. J 2021.014965 <br />ANCHOR BOLT, THREADED ROD, OR DOWELED REINFORCING STEEL MAY BE EMBEDDED TO THE SPECIFIED DEPTH, IN O W <br />A HOLE AS SPECIFIED BY MANF (TYPICALLY 1/16" TO 1/8" GREATER THAN SPECIFIED ANCHOR DIAMETER). z DRAWN: O <br />ADHESIVE/EPDXY MUST FILL THE HOLE IN THE CONCRETE AND WOOD BOTTOM PLATE. MANUFACTURER'S = ASH o <br />SPECIFICATIONS MUST BE FOLLOWED FOR PROPER INSTALLATION. U O <br />2. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR DRY USE ONLY, UNO. ALL WATERPROOFING AND FIRE SAFETY L CHKD' LO <br />SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHER. X VA (A <br />3. ALL METAL CONNECTORS SPECIFIED ON PLAN ARE IN ADDITION TO FRAMING FASTENER REQUIREMENTS LISTED IN W W <br />TABLE 2304.10.1 <br />4. BEAMS IDENTIFIED BY NUMBER ON PLAN ARE TO BE PROVIDED BY TRUSS MANUFACTURER OR LUMBER SUPPLIER. <br />5. FASTEN ALL MULTI -PLY STUD COLUMNS AND CORNERS TOGETHER WITH (2) ROWS 10d @ 8" O.C. STAGGERED. X U <br />UPPER LEVEL MULTI -PLY STUD GROUPS BELOW ALL GIRDER LOCATIONS TO BE CONTINUOUS THROUGH FLOOR Q ttt��� cn <br />SYSTEM TO FOUNDATION. (NOT REQUIRED BELOW HEADER JACK/KING STUD GROUPS) ``����5'(IN• LgN7� �,�� (� <br />6. FASTEN ALL STUDS TO BOTTOM AND TOP PLATES WITH (4)8d TOE NAILS OR (2)16d COMMON END NAILS. % �� ••• G E N '9 �� O <br />7. FASTEN ALL TRUSSES AND RAFTERS TO TOP PLATES WITH (3)8d TOE NAILS. m '� .••�,� `SF'•• ��+ z <br />8. ALL MULTI -PLY TRUSS GIRDERS AND BEAMS TO HAVE SOLID STUD GROUP BELOW MATCHING GIRDER OR BEAM <br />THICKNESS AND MATCHING WALL STUD SPECIFICATIONS AS NOTED ON STRUCTURAL PLAN, LINO. Z <br />9. EXTERIOR WALL DESIGN ASSUMES CONTINUOUSLY SHEATHED WITH OSB OR PLYWOOD -' <br />'STATE OF <br />W <br />(n <br />•FO467;45... 0��i CAS; • • R Z <br />Q <br />O 12-29-2021 p <br />�- w <br />co <br />U_ REVISIONS: <br />U_ r <br />Q No. Description Date - w <br />-- - J <br />>- I U <br />C� U) <br />O I- <br />O <br />z <br />= 0 <br />U <br />w <br />H <br />X STm1 <br />W <br />a_ <br />Q <br />CMUIMETAL CONNECTOR ENGINEERING <br />