My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38341 Springhead Ln
Zephyrhills
>
Building Department
>
Building Plans
>
38341 Springhead Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:29:04 PM
Creation date
2/19/2025 2:35:24 PM
Metadata
Fields
Template:
Building Plans
Street #
38341
Location
Springhead Ln
Contractor
D R Horton
Building Plans - Permit #
3551
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 944B87A4-AB83-4B43-8866-F48BO5ABCOB7 <br />O <br />O <br />u7 E <br />r- O <br />N C} <br />00 <br />V <br />0 O <br />APEX <br />N <br />N X <br />J <br />LL <br />W <br />J <br />J_ <br />Z <br />O <br />Cn <br />Y <br />0 true design studios <br />O <br />O <br />w 9000 REGENCY SQUARE BLVD. O <br />SUITE 100, JACKSONVILLE, FL 32211 <br />O <br />c <br />00 <br />HoRsHOMON' <br />ELECTRIC METER a <br />ELECTRIC METER FIELD VERIFY LOCATION <br />/ FIELD VERIFY C'J ' <br />/ LOCATION APPLY STUCCO SCRATCH COAT AND ONE (1) <br />0<1 <br />PRE FORMED CONTROL ' <br />JOINT W/ STRIP LATH 5/8" CEMENT PLASTER <br />LAYER OF PAINT PRIOR TO INSTALLING ELECTRIC U <br />METER <br />12" WIDE SELF-ADHESIVE � Z .. <br />FLASHING CENTERED UNDER CAVITY TO BE FILLED w <br />I , ` ar CONTROL JOINT (CLEAN - <br />`� MASONRY BEFORE APPLYING) WITH RIGID POLYMERIC W <br />ISOCYANOTE-POLYBLEN <br />111J FOAM ("GREAT STUFF" OR 00 <br />\ / SIMILAR) /O <br />/ APPLY A SILICON BASE ti <br />STUCCO FINISH SEALANT AT POINT THAT <br />�T ' _ -_ _ � - - ' ELEC WIRE PENETRATES LO <br />5/8" CEMENT PLASTER / <br />12" WIDE SELF-ADHESIVE / O SELF ADHESIVE <br />� OVER TOP &SIDES i Z <br />FLASHING CENTERED UNDER <br />CONTROL JOINT (CLEAN \ SELF FLASHING (Jj <br />MASONRY BEFORE APPLYING) / <br />UNIT W <br />/ - - 1--- --- PROVIDE STUCCO z <br />PRE -FORMED CONTROL ---. - _ -- i <br />• : ...� a�,�; . -- :�•' I SCRATCH COAT LARGER (n <br />JOINT W/ STRIP LATH �... - I W <br />THAN THE ELECTRIC <br />PREMANUF. METER CAN OR METER m <br />\ DRYER VENT CAP � �— <br />• I / (SET IN CONT. CAN COMBO OR METER � <br />8" CMU {�.. — SEALANT) AREA TO RECEIVE CAN AND DISCONNECT w LL <br />Yi <br />STUCCO SCRATCH COAT <br />W <br />_ W <br />i SEALANT at & 1 PAIN W! Z <br />.� <br />TOP &SIDES BACK -ROLL PRIOR TO (� <br />ELECTRIC METER z <br />INSTALLATION <br />Q <br />O <br />CONTROL JOINT - HORIZ - CMU CONTROL JOINT - VERTICAL - CMU _ DRYER VENT (BLOCK) ELECTRICAL CONDUIT PENETRATION ° 0 <br />SCALE: N.T.S. SCALE.- N.T.S. SCALE: N.T.S. SCALE: N.T.S. zz w <br />Uj Q <br />Q 0 <br />O V— <br />WOOD CONST BEYOND FIBERCEMENT -OR- VINYL LAP ~ <br />WOOD SHEATHING SIDING OVER APPROVED O j� <br />WEATHER RESISTIVE HOUSEWRAP INSTALLED PER U - <br />6" SELF -ADHERING FINISH COATING OVER PRIMED MFR WRITTEN SPECIFICATIONS Q <br />FLASHING BARRIER #1 <br />.�: THREE COAT STUCCO FINISH EXTEND HOUSEWRAP 0 Z <br />WEATHER RESISTIVE WEATHER RESISTIVE ) (7, " NOM) OVER GALV MTL LATH OVER NAILING FLANGE IY O <br />BARRIER #1 BARRIER #2 WD SHEATHING 11 OVER 15# FELT OVER APPROVED O 0 <br />VINYL ANGLED <br />a \ (RE: STRUCT) HOUSEWRAP WD SHEATHING J <br />CASING BEAD WEATHER RESISTIVE �\ \ X, (RE: STRUCT) _ r Q Z <br />(AM66-ANGLED-1250) BARRIER #2 \ 5/16" X 7 1/4" LAP FASTEN TO WD STRUCTURAL 1` _ <br />1-i \ SIDING W/ 6 REVEAL v; MEMBER at 7" O.C. MAX - MTL DRIP FLASHING W/ <br />1 HEMMED EDGE SET IN CONT <br />2 1/2" STARTER STRIP 7/ " TO 4 " MID -WALL - a <br />/ WEEP SCREED BEAD OF SEALANT Z <br />CORNER BEAD / DO NOT CAULK OR�- TRIM (RE: ELEVATION) } <br />LL <br />8" CMU (FASTENER 8 6" SELF -ADHERING F '� SEAL OPENING — + _ Z D- (� J <br />o z -T.� SPACING at 7"O.C.) FLASHING / — N Q EXTEND 12" SELF -ADHERING <br />O <br />z o :� .. < GALV D METAL „Z„ : ' _ L: Q <br />m a GALV D METAL MEMBRANE FLASHING OVER U <br />Q F- N l� -- <br />� _� i �u N Z FLASHING FLASHING - 6 WIDE STRIP SELF ADHESIVE WINDOW FLANGE SET IN CONT O (n <br />W w = H FLASHING, CLEAN MASONRY _ BEAD OF SEALANT = 0 <br />1 1/4" X6" SIMULATED 'r'' -i:� <br />Ljj <br />0' > _ � � DO NOT CAULK OR _ \ BEFORE APPLYING - VINYL FLANGE CASING BEAD U PROJECT NO: <br />Q _ A OPENING — _ _ :; — _ - W <br />SEAL WOOD TRIM MEMBER INSTALLED PER MFR Q <br />.a 1/2" (MIN) STUCCO FINISH WRITTEN SPECS (TYP) z <br />— / STUCCO TEXTURED PER COMMUNITY X (j <br />CMU 1 1/4" X 6" SIMULATED '' . I 1/2" (MIN) STUCCO FINISH W - <br />VINYL CASING WOOD TRIM MEMBER ; CASING BEAD SPECIFCATIONS ( DRAWN. <br />_ ' . y OMMUNITY MJP W <br />TEXTURED PER C a <br />SPECIFCATIONS <C <br />X CHKD: <br />BEAD (AM66-1250) --- 1/2" (MIN) STUCCO FINISH - -- -- - - 0 <br />TEXTURED PER COMMUNITY �• <br />1/2" (MIN) TEXTURED SPECIFCATIONS SEAL GAP W/ CAULKING / Q TSD W <br />FINISH at MASONRY OR APPROVED SEALANT / . STUCCO O <br />STUCCO CASING BEAD STUCCO SIDING m o <br />O <br />0 u7 <br />RAISED BAND at BLOCK CORNER BEAD at BLOCK SIDING TO STUCCO HORIZONTAL MATERIAL TRANSITION (FRAME TO BLOCK) Z `� <br />SCALE: N.T.S. SCALE: N.T.S. FRAME TO BLOCK SCALE: N.T.S. O� Q <br />SCALE: N.T.S. W U <br />2 <br />Q <br />z c� <br />U) z <br />1/2" (MIN) STUCCO CMU WALL W/ - CMU WALL W/ H <br />SELF ADHESIVE -OR- FLUID <br />APPLIED PAN FLASHING (CLEAN i <br />4 "STUCCO FINISH MASONRY BEFORE APPLYING) <br />FINISH TEXTURED 8 J CMU LINTEL 1!2" (MIN) STUCCO FINISH U <br />"GYP BRD OVER RE: STRUCTURAL) (RE: STRUCTURAL) (RE: STRUCTURAL) LL <br />PER COMMUNITY -_ ( _ EXTEND UP AT JAMBS (4"MIN) GYP BRD OVER 1�" GYP BRD OVER Q U' <br />SPECIFCATIONS b2" GYP BIRD OVER PRE -SHAPED STUCCO BAND T PRE -SHAPED STUCCO BAND I <br />1x2 TREATED _ 1x2 TREATED z <br />1 <br />1x2 TREATED W/ SLP TOP INSTALLED PER FURRING <br />TREATED _ W/ INSTALLED PER MFR — _ (n <br />FURRING STRIPS --'` - MFR WRITTEN SPECS (RE: FURRING STRIPS --" FURRING STRIPS FURRING STRIPS <br />;x_ <br />WRITTEN SPECS (RE: ELEV) PRECAST CONCRETE SILL at CMU WALL (TYP)- CONTINUOUS BEAD at CMU WALL TYP - CONTINUOUS BEAD <br />FLANGE CASING at CMU WALL (TYP) ELEV) at CMU WALL (TYP) OF SEALANT ( ) OF SEALANT >' REVISIONS: Q <br />SELF ADHESIVE -OR- FLUID SELF ADHESIVE -OR- FLUID PT 1x4 0 <br />BEAD APPLIED FLASHING (CLEAN WOOD BLOCKIN APPLIED FLASHING (CLEAN 4e" BACKER ROD W/ SEALANT PT 1x4 SELF ADHESIVE -OR- SELF ADHESIVE -OR- 0 NO. Description Date <br />MASONRY BEFORE APPLYING) ME _... <br />PT 1x WOOD BUCK MASONRY BEFORE APPLYING) VINYL FLANGE CASING BEAD FLUID APPLIED PT 2x4 FRAME FLUID APPLIED -� W <br />GYP BIRD OVER INSTALLED PER MFR PT 2x4 FRAME ANCHOR FLASHING CLEAN ANCHOR FLASHING (CLEAN U) <br />l PT 1x WOOD BUCK VINYL FLANGE CASING BEAD VINYL FLANGE CASING BEAD ( Z <br />T. 1x2 TREATED WRITTEN SPECS (TYP) SHIM AS NEEDED MASONRY BEFORE MASONRY BEFORE - W <br />SHIM AS NEEDED INSTALLED PER MFR SHIM AS NEEDED INSTALLED PER MFR gpP�Y NG� SHIM AS NEEDED 2 <br />FURRING STRIPS CMU STEMWALL W/ METAL DOOR FRAME APPLY NG� - - -- WRITTEN SPECS (TYP) WRITTEN SPECS (TYP) 1 I METALI DOOR FRAME U I = <br />at CMU WALL (TYP) 48" STUCCO FINISH W W <br />l 48" BACKER ROD W/ SEALANT �8" BACKER ROD W/ SEALANT (RE: STRUCTURAL) INTERIOR EXTERIOR INTERIOR EXTERIOR - - J <br />INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR W 1-- -- U <br />a- W <br />CASING BEAD at WN WINDOW HEAD at CMU WINDOW JAMB at CMU WINDOW SILL at CMU DOOR HEAD at CMU DOOR JAMB at CMU Q � <br />o <br />SCALE: N.T.S. SCALE: 1 ti2" = 1'-0" SCALE: 1 ti2" = 1'-0" SCALE: 1 1/2" = 1'-0" SCALE- 1 ti2" = 1'-0" SCALE.- 1 1/2" = 1'-0" z <br />A50 1 O <br />0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.