Laserfiche WebLink
DocuSign Envelope ID. 64039112-CEE74F45-AD73-5621"11EFF3F4 <br />I <br />Foote <br />Re -Bar (sized <br />according to <br />foundation plan) <br />♦ G- <br />#4 awg CU bare w/ 10' stubbed <br />outside of slab at service <br />location. Connect to Footer steel <br />w/ (2) ground clamps 5' apart <br />UFER GROUND DETAIL <br />N.T.S. <br />ELECTRICAL RISER DIAGRAM <br />OPTIONAL OVERHEAD <br />SAME AS <br />UNDERGROUND 150 OR 200 150 = #1 Copper or 2/ 0 Aluminum <br />AMP SERVICE 200 = 2 /0 Copper or 4 /0 Aluminum in 2" <br />Conduit. A/C DISCONNECT <br />i <br />(M-ETIR)IN <br />i <br />DISC. - #12 COPPER TO APPLIANCES AND GFI <br />150 <br />5OMP TYPICAL <br />0 R <br />N.T.S. <br />ELECTRICAL _ #14 COPPER TO LIGHTS AND OUTLETS <br />PANEL #10 COPPER TO WATER HEATER <br />- SERV. BY #8 COPPER TO RANGE <br />ERV. B#6 COPPER TO HVAC <br />POWER CO. <br />\1 <br />#4 GROUNDING WIRE WITH CODE APPROVED CLAMP TO EITHER: <br />A) APPROVED GROUNDING ROD WITH MINIMUM 8' DEPTH <br />B) BONDED TO CONTINUOUS FOOTING STEEL <br />— INTERSYSTEM BONDING TERMINATION PER NEC 250.94 <br />NOTE: <br />ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70, LOCAL CODES AND LOCAL POWER/UTILITY COMPANY <br />GENERAL ELECTRICAL NOTES <br />ABBREVIATIONS LEGEND <br />ALL ELECTRICAL DESIGN AND WORK SHALL BE IN STRICT <br />COMPLIANCE WITH THE 2017 NATIONAL ELECTRIC CODE <br />ABV ABOVE <br />AC AIR CONDITIONER <br />• PER NEC SECTION 210.12 (B) ALL 15A & 20A, 120V <br />AFF ABOVE FINISHED FLOOR <br />BRANCH CIRCUITS SUPPLYING OUTLETS REQUIRE <br />AHU AIR HANDLER UNIT <br />AFCI PROTECTION <br />BLK BLOCK <br />CABS CABINETS <br />• CARBON MONOXIDE PROTECTION PER FLORIDA <br />CLG CEILING <br />STATUTES 553.885 (2). TO BE INSTALLED WITHIN 10' <br />CHR CHAIR RAIL <br />OF EVERY SLEEPING ROOM <br />COFF COFFERED <br />COL COLUMN <br />• ALL OUTLETS SHOULD BE AFCI PER NEC - U.N.O. <br />COND CONDENSER <br />CRN CROWN MOULDING <br />CVAC CENTRAL VACUUM SYSTEM <br />• PER NEC SECTION 210.8(B)(5) ALL 15A & 20A, 15V <br />RECEPTACLES INSTALLED OUTDOORS MUST BE <br />DBL DOUBLE <br />DIAG DIAGONAL <br />GFCI-PROTECTED <br />DR DOOR <br />DRY DRYER <br />• PER NEC SECTION 210.8(B)(5) ALL 15A & 20A, 15V <br />DW DISHWASHER <br />RECEPTACLES INSTALLED WITHIN 6' OF SINK (IN <br />EB EYEBROW <br />NON -DWELLING OCCUPANCIES-i.e. OUTDOOR <br />FL FLOOR LINE (MAT. CHANGE) <br />SUMMER KITCHENS RECEPTACLES) MUST BE <br />FLR FLOOR <br />GFCI-PROTECTED <br />FP FIREPLACE <br />FXD FIXED <br />• PER NEC SECTION 406.8(B)(1) 15A & 20A <br />FXT FIXTURE <br />RECEPTACLES IN A WET LOCATION MUST BE WITHIN <br />GLS GLASS <br />AN ENCLOSURE THAT IS WEATHERPROOF WHEN AN <br />HB HOSE BIB <br />ATTACHMENT IS PLUGGED IN AN ALL NON -LOCKING <br />KS KNEE SPACE <br />RECEPTACLES SHALL BE LISTED AS WEATHER <br />LAV LAVATORY <br />RESISTANT <br />LT LAUNDRY TUB <br />MRBL MARBLE <br />• PER NEC SECTION 406.11 IN DWELLING UNITS, ALL <br />MC MEDICINE CABINET <br />15A & 20A, 15V RECEPTACLES SHALL BE LISTED AS <br />MIR MIRROR <br />TAMPER -RESISTANT <br />MTL METAL <br />OH OVERHEAD <br />• PER NEC SECTION 800.156 NO LESS THAN ONE <br />OPNG OPENING <br />COMMUNICATION OUTLET SHALL BE INSTALLED <br />OPT OPTIONAL <br />WITHIN EACH DWELLING UNIT <br />R & S CLOTHES ROD and SHELF <br />REF REFRIGERATOR <br />• PER NEC SECTION R314.3 AND R315.1 SMOKE <br />SD SOAP DISH <br />DETECTORS TO BE INSTALLED INSIDE EACH <br />SDLTS SIDE LIGHTS <br />SLEEPING AREA <br />SGD SLIDING GLASS DOOR <br />SH (2) SHELVES (QUANTITY) <br />• ALL SMOKE ALARMS SHALL BE LISTED AND LABELED <br />SHWR SHOWER <br />IN ACCORDANCE WITH UL 217, PER FBC 314.1. GC TO <br />TB TOWEL BAR <br />INSTALL; KIDDE MODEL # 14618A SMOKE ALARM, OR <br />TPH TOILET PAPER HOLDER <br />APPROVED EQUAL <br />T&S TUB and SHOWER <br />TEMP TEMPERED <br />• PROVIDE GAS DROPS AS PER COMMUNITY ONLY <br />TR TRANSOM <br />VOL VOLUME <br />WC WATER CLOSET <br />• JUNCTION BOX AT WATER HEATER, RANGE AND/OR <br />WD WOOD <br />DRYER TO BE 220V IN NON GAS COMMUNITIES, AND <br />WH WATER HEATER <br />110V IN COMMUNITIES THAT HAVE GAS OPTIONS <br />WNCT WAINSCOT <br />PROVIDE APPROPRIATE RECEPTACLE PER <br />WS WATER SOFTENER <br />APPLIANCE <br />WASH WASHER <br />• ALL LAMPS SHALL BE HIGH -EFFICACY TO COMPLY <br />WITH FBC-EC R404.1 - (LOW -VOLTAGE LAMPS <br />EXCLUDED). <br />• PER FBC-R M1305.1 A LEVEL WORKING SPACE NOT <br />LESS THAN 30" DEEP AND 30" WIDE SHALL BE <br />PROVIDED IN FRONT OF THE CONTROL SIDE OF ANY <br />APPLIANCE <br />- <br />ROOF NOTES <br />• INSTALL ROOF VENTING PER MFR WRITTEN <br />INSTRUCTIONS PER FBC R806 <br />• ALL OVERHANG DIMENSIONS ARE TO EDGE OF <br />RAFTER. REFERENCE WALL SECTIONS/DETAILS <br />FOR ALL OVERHANGS NOT DIMENSIONED. <br />• ALL UNDERLAYMENT MUST BE INSTALLED IN <br />COMPLIANCE WITH FBC R905.1.1 <br />• EACH 4' OFF RIDGE VENT REQUIRES (1) 46" x 3" CUT <br />OUT IN ROOF SHEATHING PER MFR WRITTEN <br />INSTRUCTIONS <br />EXTERIOR ELEVATION GENERAL NOTES <br />• FRONT ELEVATIONS TRIM, MOLDING, COLUMNS <br />AND TRIM SHALL RECEIVE A PAINTED FINISH PER <br />BLDR SPECS, SEE ELEVATION FOR DEPTH OR <br />RAISED TRIM <br />• SIDE AND REAR ELEVATIONS TRIM AROUND <br />WINDOWS AND DOORS MAY BE OPTIONAL PER <br />COMMUNITY SPECS - SEE COMMUNITY <br />SPECIFICATIONS OR CONSULT THE <br />CONSTRUCTION MANAGER. ALL TRIM SHALL <br />RECEIVE A PAINTED FINISH PER BLDR SPECS <br />• ROOF COVERING SEE COMMUNITY <br />SPECIFICATIONS OR CONSULT THE <br />CONSTRUCTION MANAGER. SEE STRUCTURAL <br />SHEETS FOR SHEATHING REQUIREMENTS <br />• FLASHING SHALL BE INSTALLED AT WALL AND <br />ROOF INTERSECTIONS, DECK AND WALL <br />INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN <br />ROOF SLOPE OR DIRECTION, AND AROUND ROOF <br />OPENINGS <br />• WALL HEIGHTS VERIFY ALL BEARING WALL <br />HEIGHTS WITH FINAL TRUSS LAYOUTS <br />• WATER -RESISTIVE BARRIERS PER R703.7.3, <br />WATER -RESISTIVE BARRIERS SHALL BE INSTALLED <br />AS REQUIRED IN SECTION R703.2 AND, WHERE <br />-- - - - APPLIED OVER WOOD -BASED SHEATHING, SHALL <br />ROOF VENT CALCULATION INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE <br />BARRIER WITH A PERFORMANCE AT LEAST <br />I EQUIVALENT TO TWO LAYERS OF GRADE D PAPER <br />FORMULA: <br />1 SQUARE INCH VENT FOR EVERY 300 SQUARE INCHES <br />OF CEILING <br />`144 SQ. IN. = 1 SQ. FT. <br />BLDG. CEILING (SF) x 144 = BLDG (SQ. IN.) <br />BLDG. (SQ. IN.) 1300 = SQ. IN. OF VENT REQUIRED <br />SQ. IN. OF VENT REQUIRED / 2 = 50% AT HIGH AND 50% <br />AT LOW. <br />PER FBC SECTION R806.2: 40% MIN, BUT NOT MORE <br />THAN 50% OF VENTILATION MUST BE PROVIDED BY <br />VENTILATORS LOCATED NO MORE THAN 3'-0" BELOW <br />THE RIDGE OR HIGHEST POINT OF THE SPACE <br />BASIS OF CALCULATION: ("OR EQUAL" ACCEPTABLE) <br />(a) OFF RIDGE VENTS - STAMPCO W/ 36 SQ IN (NFVA) <br />PER LINEAL FT <br />(b) SOFFIT VENTS - GP T3-1/3" FULL VENT PERFORATED <br />W/ 9.19 SQ IN (NFVA) PER LINEAL FT <br />CALCULATED LINEAL FOOT OF SOFFIT VENT SHALL <br />NOT INCLUDE NON -VENTED FIRE RATED SOFFIT <br />LOCATED LESS THAN 5' FROM PROPERTY LINE <br />THE INDIVIDUAL LAYERS SHALL BE INSTALLED <br />INDEPENDENTLY SUCH THAT EACH LAYER <br />PROVIDES A SEPARATE CONTINUOUS PLANE AND <br />ANY FLASHING (INSTALLED IN ACCORDANCE WITH <br />SECTION R703.4) INTENDED TO DRAIN TO THE <br />WATER -RESISTIVE BARRIER IS DIRECTED <br />BETWEEN THE LAYERS <br />GENERAL NOTES <br />• ALL CONSTRUCTION SHALL MEET THE LATEST <br />EDITION OF CODES ADOPTED BY THE LOCAL <br />GOVERNING AGENCIES <br />• PER FBC R302.5 NO OPENINGS FROM A PRIVATE <br />GARAGE ARE PERMITTED DIRECTLY INTO SLEEPING <br />AREAS. ALL OPENINGS SHALL HAVE SOLID WOOD, <br />INSULATED STEEL OR 20 MIN. FIRE RATED DOORS <br />NOT LESS THAN 1-3/8 INCHES THICKNESS, EQUIPPED <br />WITH A SELF CLOSING DEVICE. ALL DUCTS IN THE <br />GARAGE OR PENETRATING THE WALL OR CEILING <br />SEPARATING THE GARAGE AND DWELLING SHALL BE <br />CONSTRUCTED OF MIN. 26 GA. SHEET METAL, 1 INCH <br />MINIMUM RIGID CLASS 0 OR 1 DUCT BOARD, OR <br />OTHER APPROVED MATERIAL AND SHALL HAVE NO <br />OPENINGS INTO THE GARAGE <br />• PER FBC TABLE R-302.6 GARAGE SHALL BE <br />SEPARATED FROM RESIDENCE AND IT'S ATTIC W/ <br />MIN. 1/2" GYP BOARD ATTACHED IN ACCORDANCE <br />WITH TABLE R702.3.5. HABITABLE ROOMS SHALL BE <br />SEPARATED FROM ROOM ABOVE W/ MIN 5/8" TYPE <br />"X" GYP BOARD, WHERE THE SEPARATION IS A <br />FLOOR -CEILING ASSEMBLY. ANY STRUCTURE <br />SUPPORTING THE ASSEMBLY SHALL BE PROTECTED <br />W/ MIN 1/2" GYP BOARD <br />• PER FBC R309.1 GARAGE AND CARPORT FLOOR <br />SURFACE AREAS USED FOR PARKING OF <br />AUTOMOBILES OR OTHER VEHICLES SHALL BE <br />SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS <br />TO A DRAIN OR TOWARDS THE MAIN VEHICLE ENTRY <br />DOORWAY <br />• PER FBC R-312.1 PORCHES, BALCONIES OR RAISED <br />FLOOR SURFACES LOCATED MORE THAN 30" ABOVE <br />FINISHED FLOOR OR GRADE SHALL HAVE GUARDS <br />NOT LESS THAN 36" IN HEIGHT. PER FBC R-312.1.2 <br />OPEN SIDES OF STAIRS WITH A TOTAL RISE OF <br />MORE THAN 30" ABOVE FINISHED FLOOR OR GRADE <br />SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT <br />MEASURED VERTICALLY FROM THE NOSING OF THE <br />TREADS <br />• PER FBC R-312.1.3 REQUIRED GUARDS ON OPEN <br />SIDES OF STAIRWAYS, RAISED FLOOR AREAS, <br />BALCONIES AND PORCHES SHALL HAVE <br />INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES <br />WHICH DO NOT ALLOW PASSAGE OF A SPHERE 4" <br />OR MORE IN DIAMETER <br />• PER FBC R-308.4.5 GLAZING IN WALLS, ENCLOSURES <br />OR FENCES CONTAINING OR FACING HOT TUBS, <br />SPAS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, <br />BATHTUBS, SHOWERS AND INDOOR OR OUTDOOR <br />SWIMMING POOLS WHERE THE BOTTOM EXPOSED <br />EDGE OF THE GLAZING IS LESS THAN 60 INCHES <br />MEASURED VERTICALLY ABOVE ANY STANDING OR <br />WALKING SURFACE, SHALL BE CONSIDERED A <br />HAZARDOUS LOCATION. G.C. TO VERIFY IF <br />HOMEOWNER SELECTS ANY OF THESE ITEMS <br />LISTED. IF ANY OF THESE ITEMS LISTED IS <br />INSTALLED, SUCH GLAZING FACING THOSE ITEMS IS <br />TO BE TEMPERED <br />• PER FBC R312.2, PROVIDE WINDOW FALL <br />PROTECTION IN ACCORDANCE WITH R312.2.1 AND <br />R312.2.2 <br />• GAS OPT. PER COMMUNITY. VERIFY WITH BLDR <br />• C.J. = RECOMMENDED MASONRY CONTROL JOINT <br />LOCATION <br />• ALL FINISHES, MATERIALS, HOUSEWRAP, WINDOW <br />AND DOOR FLASHING, TAPING AND SEALANTS TO BE <br />INSTALLED PER BUILDER PROVIDED <br />SPECIFICATIONS OR MFR WRITTEN INSTRUCTIONS <br />• ALL FINISH DETAILS & TYPICAL PLAN NOTES <br />PROVIDED BY BUILDER IN ACCORDANCE WITH <br />TYPICAL BUILDER SPECIFICATIONS <br />• REFER TO STRUCTURAL ENGINEERING DRAWINGS <br />FOR ALL EXTERIOR WALL STUD SPECIES, SIZES AND <br />SPACING <br />r` o <br />r` <br />O ° <br />APEX <br />W � <br />Z qj <br />m <br />W <br />W <br />Z <br />Z � <br />W tds -6 <br />Q true design studies N <br />O <br />J 9000 REGENCY SQUARE BLVD. N <br />W SUITE 100, JACKSONVILLE, FL 32211 <br />Z 904.821.5200 p <br />of <br />O <br />O 061HOMON' <br />U <br />/i <br />6' f <br />O OKM=� <br />J <br />IL <br />U <br />Z N <br />f} <br />v <br />O <br />O <br />Z <br />2 <br />U <br />W <br />H <br />w J <br />W <br />W ") <br />Q W <br />p <br />m <br />o z W <br />W Z O <br />VJ <br />O <br />w Q O <br />Q <br />Z q• W <br />o 41 � W <br />I- 00 W 0� o <br />t <br />Q <br />U) X <br />O Z <br />J O <br />O o <br />Z W <br />= H <br />U Z <br />Abbott Park <br />X a <br />W <br />a LOT 020-03-1 B w <br />Q <br />U <br />0 <br />W <br />PROJECT NO: F- <br />2021.014970 z <br />O <br />DRAWN: <br />CD w <br />- - o <br />CHKD: tL <br />JAC O <br />0 <br />0 <br />LO <br />W <br />w <br />J <br />Q <br />U <br />U) <br />(D <br />Z_ <br />W <br />12-29-2021 (D <br />Z <br />REVISIONS: <br />No. Description Date <br />w <br />U) <br />- w <br />w <br />W <br />I_ <br />AOOO Z <br />O <br />I") <br />