Laserfiche WebLink
1 TR11RUt4'Rq�41TR <br />JocuSlgn Envelope ID: 82C92949-7F25 4CCA-966E-E7FE1C6E6CB1 <br />EXISTING EXTERIOR CMU <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/s' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />- <br />�� o <br />D � <br />f D <br />o ° EXISTING FOUNDATION. <br />I p n <br />I � <br />D \ <br />• D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES i <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOW SILL . �t <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE I <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO o <br />EXISTING FOUNDATION FACE w/ I • p o - p o - - o- <br />(2) ROWS OF 3/s' DIA. TAPCONS / <br />OR CUT NAILS @ 24" O.C. COVER D o <br />FLUSH w/ 3000psi CONCRETE. I <br />D EXISTING FOUNDATION <br />I, <br />I I \ n <br />D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. SEE ARCH <br />(MAX 20" <br />e i - -- DEEP) <br />d ° e <br />a e T Q" <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />6 BEARING CURB STEP SECTION <br />16" <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />' AM �� ^^"'T'"" '^US BAR AS <br />_AP AS SHOWN <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL <br />MU <br />LITHIC <br />) DEGREE <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. <br />W <br />\\ \ \ \ <br />Of- o <br />\/\ W ~ LO <br />VAPOR BARRIER �i � o � <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />L o\\j <br />\\/\ ADDITIONAL #4 OR <br />FOOTING TO BEAR ON FIRM //� #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. 1-6 <br />(BEYOND) <br />FLOATING CONCRETE _w U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1A U (n (1) #4 OR #5 <br />WWF OR FIBERMESH > , I Q LUQ Cn CONT <br />w <br />cn <br />D FINISH <br />.e o.. O GRADE <br />Lo <br />#4 OR #5 VERT REINFORCING I //\\ <br />UP TO 3 COURSES: 72" <br />4 TO 5 COURSES: 48" O.C. <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />(1) #4 OR #5 CONT. <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 24" <br />INTO MONOLITHIC THICKENED EDGE <br />MIN 24" LAP <br />36" MAX VARIES PER <br />ARCH PLANS <br />4" CONCRETE SLAB W/ <br />_ - ,� -°_ < <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />- <br />\\/\\ \\ <br />v� <br />- <br />_ <br />----- <br />--- <br />- --a-I' <br />-----�.--�-e\% <br />12" MIN <br />U) <br />.I <br />° ea '. ° a ° <br />#4 OR #5\�//\/� <br />0 - <br />OU <br />, , ° <br />REINFORCING PER <br />¢ <br />e ° <br />° <br />MONOLITHIC FOOTING <br />SECTION <br />6" OPT. EXTENSION <br />F- <br />1 ° < <br />e <br />° 41 ° e <br />IN BRICK LOCATIONS <br />e LA <br />FOOTING TO BEAR ON FIRM <br />ON FND PLAN <br />° <br />e° <br />UNDISTURBED SOIL <br />MIN112" <br />\ \ \ \ \ <br />//�//\//�//�//\//\//\ <br />ADDITIONAL NO.4 OR NO. 5 <br />BAR IN BRICK LEDGE <br />< <br />• e 1 d° <br />IN <br />A\ <br />±_ - __& - - <br />- <br />� <br />//�//\//\�/\�/\�/\//\// //\//\//\\�/' ' <br />• STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />• ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />LOCATE <br />AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT IN LAST <br />REINFORCEMENT <br />STEMWALL CELL <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />b <br />3 %2' CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />MINIM �2_(1) #4 OR #5 90" BEND @ 48" O.C. <br />----a -°a <br />/ VAPOR BARRIER <br />e '\ <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />#4 OR (2) #5 CONT <br />16" UNDER 2 STORY WALL W/ <br />#4 OR (2) #5 CONT <br />MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />*NOTE*: IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE 1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 SEE NOTES (MAX 16") U <br />W1.4 x W1.4 WWF OR o <br />FIBERMESH STUCCO OR DIRECTLY ADHERED cli <br />STONE CLADDING FINISH - MIN 6" a, <br />ALL OTHER EXTERIOR WALL `li 0 <br />CLADDING - MIN 8", U.N.O. ON ARCH a <br />cr <br />VAPOR BARRIER /\\//\\ ° o \\ \//�\///\\//\\//\\//\\/\\/� O <br />XON /%/%/%/%/% APEX <br />00 <br />00 <br />FOOTING TO BEAR ON �\ / � Q, <br />6"OPT. EXTENSION IN BRICK <br />FIRM UNDISTURBED LOCATIONS ON FND PLAN <br />SOIL I <br />12" UNDER 1 STORY WALL W/04 <br />N <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO.4 OR NO. 5 c <br />BAR IN BRICK LEDGE <br />J 16" UNDER 2 STORY WALL w/ LL. 1✓ <br />(2) #5 OR (3) #4 CONTINUOUS s <br />W <br />J tds �i <br />1 MONOLITHIC FOOTING SECTION j true assign studios °' <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Z <br />FOLLOWING OCCUR: O <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" W <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY U 9000 REGENCY SQUARE BLVD. <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY Q SUITE 100, JACKSONVILLE, FL 32211 <br />PER T-0" HORIZONTALLYfO PREVENT EROSION OF SOIL. O <br />O <br />CONCRETE SLAB w/ 6x6 O <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR r fury <br />FIBERMESH W U. <br />041HOMON, <br />co <br />m <br />16" / VAPOR BARRIER WZ <br />Q <br />3 BEARING WALL FOOTING SECTION <br />z <br />W <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR W <br />FIBERMESH 0f This item has been electronically <br />0'-0" A.F.F. � signed and sealed by Justin M Lanier, <br />° SEE ARCH O PE on the date and/or time stamp <br />O shown using a digital signature. <br />° e DETAILS g g <br />d \° i Printed copies of this document are <br />not considered signed and sealed <br />Zand the signature must be verified <br />8" MIN LO by a 3rd Party Certificate Authority <br />1 °° O Oon any electronic copy <br />8 x8 THICKENED 8" ZFTG AT LLJ <br />STEP-DOWN, EE VAPOR BARRIER W illIll. m-/ <br />PLAN Wz LL L.L <br />CURB STEP SECTION U) z W <br />4 m O w <br />J - <br />VAPOR BARRIER <br />W W � 2 <br />8" UNDER MASONRY WALL <br />W <br />Z <br />6" UNDER WOOD WALL 0 \ Q Q <br />ES� W W W <br />SEE ARCH <br />(MAX 16") Q <br />e e 0 W W <br />/ /\/ / / <br />�/ /�\/��//\\//\\//\\/\\/� � x <br />a / 12" MI\/\/ _ <br />LL <br />LL <br />Z <br />O <br />6" OPT. EXTENSION IN BRICK < <br />LOCATIONS ON FND PLAN O 1-- <br />a- z <br />ADDITIONAL NO.4 OR NO. 5 IY <br />BAR IN BRICK LEDGE 0 W <br />Q LL <br />Ix Abbott Park Q <br />5 GARAGE EXT WALL CURB SECTION <br />O U <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE J (n <br />FOLLOWING OCCUR: U- LOT 008-04-1 B 0 <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" W <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY z Z <br />PER 3'-0" HORIZONTALLWO PREVENT EROSION OF SOIL. - 0 <br />} W <br />CONCRETE SLAB W/ 6x6 PROJECT NO: W <br />W1.4 x W1.4 WWF OR 0 0 <br />FIBERMESH O 2021.012599 W <br />0'-0" A.F.F. SEE ARCH Z 0 <br />DRAWN: <br />(MAX 20" = Ci D 8 <br />° 4 a DEEP) U O <br />x MJP w <br />e <br />EXTENSION 0- <br />Q <br />UNDER BRICK VENEER x U <br />12" UNDER 1 STORY WALL �.�CIN LgN�(n <br />W/ (2) #4 OR (2) #5 CONT VAPOR BARRIER } �� ,J?. C E N •. F9 �ii 0 <br />16" UNDER 2 STORY WALL Q <br />w/ (3) #4 OR (2) #5 CONT W <br />No 85166 <br />z ` * • DocuSigned by: •� * o <br />Q <br />• _ W <br />6 BEARING CURB STEP SECTION p ,0;•,DF435 .••� <br />Q �� '•• O R 1�.•'���.` Z <br />TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />--___ <br />IIL -- --- - - - - - - - <br />HOUSE SLAB <br />z <br />% <br />_'e*'SS;O E <br />3: <br />N A' 0 <br />Q <br />O_ <br />11-01-2021 <br />p <br />W <br />U_ <br />REVISIONS: <br />w <br />U- <br />Q <br />No. Description Date <br />_ <br />W <br />(A <br />Q <br />C� <br />(A <br />1 <br />O <br />0 <br />z <br />RE-ENTRANT CORNER DETAIL U o <br />(RECOMMENDED) W <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS x f;T.2 r <br />W <br />Q <br />CMU/METAL CONNECTOR ENGINEERING <br />