My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39709 Harvest Creek Ln
Zephyrhills
>
Building Department
>
Building Plans
>
39709 Harvest Creek Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 1:40:37 PM
Creation date
2/19/2025 2:36:57 PM
Metadata
Fields
Template:
Building Plans
Street #
39709
Location
Harvest Creek Ln
Contractor
Lennar Homes
Building Plans - Permit #
1233
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
II 1A <br />N <br />O <br />0 <br />0 <br />v <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 J <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Dpper to lights 8 outlets <br />Dpper to 20 amp clus <br />copper to WH <br />copper to Dryer <br />t Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FIEF <br />DUPLEX OUTLET ABOVE COUNTER <br />PETW-P <br />WEATHERPROOF DUPLEX OUTLET <br />�&GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUSTFAN <br />;iO� EXHAUST FAN/LIGHT COMBINATION <br />® D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />HP PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />[� <br />THERMOSTAT <br />ELECTRIC METER <br />_!a <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />L J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />69 <br />(1) PHONE LINE, (1) DATA PORT <br />RECEPT. <br />FC. <br />T--, <br />I I <br />L <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I I <br />UPPER ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />0 <br />N <br />0 <br />N <br />N <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residentlal 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />a <br />S <br />N <br />V <br />0 <br />n 2n <br />0L <br />J <br />'*0LL <br />:k <br />] "� 0 <br />rn h <br />M M <br />J W <br />LL J LL <br />U_a <br />rN <br />0"" <br />Z <br />13J <br />to LL ILL <br />°' <br />0- <br />2 <br />o <br />W <br />r?� <br />��inrn <br />w(�G M o <br />Q � <br />W N O< <br />N �' Z <br />O N <br />0 <br />...LL <br />Z <br />Q <br />O V <br />_i <br />❑❑❑ <br />W <br />(D <br />N th <br />O <br />Z <br />Z � <br />E3 <br />r <br />_ <br />V) <br />z A <br />(1) <br />0 <br />w <br />.O. <br />N <br />H r� <br />U <br />_■ <br />H <br />Q <br />I_ <br />r+ <br />�4p <br />M <br />� <br />D <br />Z <br />M <br />_J <br />U_ <br />i� <br />a <br />gypp,, <br />Y t <br />E <br />off® <br />Q <br />E Q <br />[U <br />F_ rO <br />E o <br />x , <br />na <br />wtt <br />O <br />00 <br />Z <br />o <br />�a <br /><S <br />� <br />m� <br />o <br />g� <br />Z <br />Q <br />W <br />W <br />T <br />Y <br />Qa <br />00 <br />�5 <br />4° <br />CIO <br />0 <br />zld <br />° 3 <br />C <br />ON <br />= <br />c <br />W <br />m <br />c <br />ca <br />Q <br />o <br />^C <br />to <br />U <br />W <br />LO <br />Ca <br />l o <br />O <br />.ttt� <br />_ N <br />T' <br />N <br />I <br />LO <br />N <br />� � <br />� <br />E <br />N <br />CY) <br />y O <br />o <br />Z <br />Z <br />E <br />c <br />c <br />0- <br />U _ <br />ci <br />Q p <br />to <br />JOB <br />NO: <br />20-8078 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.