Laserfiche WebLink
0 <br />iv <br />3 <br />2 <br />m <br />L <br />c <br />v <br />x <br />•o <br />0 <br />J <br />n <br />'o <br />00 <br />I <br />0 <br />x <br />m <br />LC) <br />a <br />W <br />a> <br />v <br />v <br />0 <br />N <br />O <br />J <br />n <br />00 <br />I <br />O <br />a� <br />/ <br />C <br />Q <br />N <br />N <br />a <br />E <br />Qi <br />0 <br />2 <br />L <br />C <br />c <br />aci <br />t7 <br />C1 <br />0 <br />c <br />UI <br />.o <br />0 <br />0 <br />O <br />0 <br />O <br />5i <br />0 <br />0 <br />v C14 <br />Co <br />N <br />v <br />0 <br />]C <br />N <br />O <br />m <br />v <br />N <br />12 <br />HEEL 12 <br />T.O.M. N <br />HDR HGT. —— <br />----------------------- <br />TEXTURED F <br />CEMENTITIOUS FINISH ❑ <br />I <br />ON C.M.U. (TYP.) I <br />2" x 4" I SMOOTH <br />TEXTURED <br />SILL / BAND <br />I <br />I <br />F.FL.— — — — — — — --— — — — — — — — — — — — — — — — — — — — — — — — — I — <br />4' RIDGE VENT <br />12 <br />�5 <br />3 TAB SHINGLES. ROOF <br />�— INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />2" 1" x 9" SMOOTH <br />TEXTURED <br />HEAD/BAND <br />I <br />I <br />---F-7 ]�� --- -- �� --- -------- <br />FRONT ELEVATION - 61 <br />LEFT ELEVATION - B1 <br />1 /4"=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />"CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />i <br />/t��6 <br />`��;;���v1t41114t011t� <br />. <br />r0t�` <br />0,�ES'S;tO��r <br />o` <br />��li?RRRtR�` <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />to <br />W <br />Q <br />Cov $ <br />4 <br />0 N (O 00 <br />0 C? N 4t <br />N m 0 <br />4. ® <br />WV <br />N <br />? t- C LL <br />5u;o) N _ W <br />M <br />Q <br />tnr.,�L a <br />LL <br />N, M W 0 <br />d <br />Z <br />JLLLL a. X <br />t <br />C)Z <br />L:ao W m O <br />02r- <br />W <br />z <br />LL <br />Jod <br />00 ci <br />LO <br />Z <br />N Cl)Z O J <br />�� ❑❑❑ <br />�W <br />Z N M <br />O <br />z <br />z o <br />J <br />Ln <br />'CDC <br />z LL <br />uJ <br />D <br />_ LL <br />[.n <br />LU <br />O <br />w o <br />N <br />-N <br />c <br />7g <br />rn <br />r— <br />w <br />f- J pE <br />I <br />N <br />®Q <br />C) <br />c U) v <br />¢ Y <br />6) <br />N <br />O <br />CC <br />W <br />M <br />mZ <br />os <br />Z <br />U_ <br />Q E <br />E <br />os <br />' <br />Z® <br />❑a <br />fBa <br />I_ ra <br />5Z <br />UO <br />O U <br />O <br />O <br />N <br />L <br />F <br />a z <br />.0 <br />Q <br />a Z <br />w� <br />(d <br />Z <br />Y <br />m O <br />O , <br />J <br />< ° <br />aW <br />z <br />co <br />a <br />01 <br />n° <br />N W <br />U 3 <br />a j <br />o' <br />1 k <br />o <br />JZ <br />w� <br />~ <br />�o <br />IIIIIIIIIIII� <br />O <br />V <br />z¢ <br />I <br />a H <br />OU <br />O <br />i M <br />N <br />LL <br />L <br />iT <br />(0 <br />C <br />N <br /><C <br />C <br />C:) <br />F'— <br />W <br />can <br />... <br />o <br />d. <br />T <br />(o NO <br />L.n <br />.� <br />= Q <br />T <br />r <br />' ` A ' <br />r <br />2 C4 <br />� � <br />r- <br />N <br />N <br />M <br />N <br />.. <br />0M <br />z <br />E Oco <br />m <br />a <br />o <br />U _J <br />a m <br />Q p <br />(D <br />_J <br />JOB <br />NO: <br />20-8077 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.1 <br />