Laserfiche WebLink
10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE 000 <br />5'-0" ¢ - <br />C7 <br />STUB -OUT FOR 1 _�o o <br />LO <br />GAS METER 0 o <br />� U <br />O � <br />N � <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-Y <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2) 16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />1 T-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" orp <br />5000s 1.8/1.7 <br />wood panels <br />nel <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.811.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1/2" <br />602.0 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking ° <br />1/8" gap ° <br />} <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP @ TOP sides by 6". <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />FILL CELL STD. 900 HOOK BOND BEAM <br />7tt <br />CONT. #5 > STD. 90° <br />HOOK <br />BAR <br />CONT. #5 <br />BAR <br />_ #5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION <br />@ INT. BRG. WALL <br />N.T.S. <br />1/8" min. }Small gap 2" min. <br />2"_., <br />• � 4 max. <br />Clinch nails <br />when <br />possible <br />Tight fit <br />2x4/Plywood/OSB web stiffener <br />required when indicated or <br />- Hangers with side nailing. <br />- Hangers with sides not containing <br />top flange of joist. <br />- Birdsmouth cuts. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />2" min. <br />4" max. <br />WEB STIFFENER <br />N.T.S. <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series 1 Depth End Intermediate <br />®, <br />BC15000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7l8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5- d <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60sP <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/(22)' <br />NAILS 1 <br />5/8"D <br />THRU <br />BOLT <br />SIMPSC <br />w/(22)' <br />NAILS 1 <br />R TRUSS <br />OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />0 LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />BLOCKING PANEL, INTERIOR <br />SQUASH BLOCKS AT INTERIOR Boise Joist Blocking Vertical load transfer =1900plfmax, along bearing wall TYPICAL SIMPSON META12 / TYPICAL SIMPSON MTS <br />BEARING Use 3" (10d) nails at 6" o.c. Required on interior walls : - for vertical load transfer Plumbing META12 TSS INSTALLATION / HTS INSTALLATION <br />Vertical load transfer =1900 plf max along load bearing wall. Load bearing walls when load bearing - for lateral support when joists <br />Load bearing wall must stack meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />*Non -stacking walls over squash=20 blocks and blocking and wall or beam below.* <br />require additional wall or beam below.4— Joist <br />consideration. Check <br />local building When joists meet over wall, provide <br />I -Joist can be offset <br />code forappropriate 1/16" 13/4'minimumbearingforeach. PLUMBING LINE <br />up to 3" to avoid <br />details in One 10d box <br />vertical plumbing TOP 2 #5's x 4'-0" <br />areas=20 of high or=20 sinker ( ) <br />lateral load. nail each side 3" max CENTERED @ PIPE PVC OR SCH40 SLEEVE <br />at bearing. A/C CHASE 4" PVC PENETRATION <br />JOISTS OFFSET SLEEVE THRU STEM <br />N.T.S. WALL d d ° °, ° C <br />-III I _— I • d ° I I I I-1 I <br />Provide adequate bearing Use 10dx3" nails at 6"o.c, for all joist a r— ° r <br />for each lapped joist. blocking panel *Non -stacking walls ° — e _ t ~r�= ; . <br />Squash block 10d nails require additional consideration. — _ — °O <br />(2x4 minimum) SECTION @ INT. BRG. WALL F11 <br />FINI GRADEBearing wall, Versa -Lam LVL or N.T.S.Glulam Beam 'i' �l I�'i'� I ICI U7'i'TTT—I <br />" `_1Z ' MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />BCE A 1%" ROUND HOLE MAY 01 6" 6"^ <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN %" <br />NOTES: <br />DO NOT CUT HOLES <br />LARGER THAN <br />ROUND IN <br />CANTILEVERS. <br />1, JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY, <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Yz" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALL SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS, IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Jc <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />\Install tight to top flange. <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4%2" gap <br />Backer Block <br />'Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />" depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />SLEEVE THRU STEM—/ "' <br />SEE PLAN FOR °. a . • • ° <br />FOUNDATION INFO ` a. ° 4' <br />STEM FOUNDATION <br />GRADE <br />° <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />REINF. SEE PLAN <br />(2) #5 REBAR <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />'=-- SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />4' . ° ., .a <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 44" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />a <br />d e °a. A av G <br />d <br />A _ <br />rr <br />SEE FND. PLN. <br />SIZE & REINF. <br />I <br />S <br />�_ <br />� <br />J <br />r� <br />r tt f� Q <br />eFF'+EOn { <br />OF <br />r <br />�''<ElfdliitrtE6�5� <br />�� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W <br />Q <br />r' <br />V 8 � ,� <br />O M N r <br />NN6 LL <br />� q <br />0 <br />(O <br />N N X.k LL <br />7 <br />M <br />�) <br />Q <br />cn r, r� LL w a- <br />M , a Y <br />M JV wrn <br />J LL l d <br />z <br />v <br />t m 0 I <br />_ <br />IV@Nco <br />LL O J <br />W <br />��C° aoa ¢¢ <br />Z <br />IL <br />ILU <br />,, a <br />m Z fY D O <br />Z <br />N <br />U � 1p <br />W <br />❑ ❑ ❑ <br />M C, <br />� N O <br />z co <br />z <br />o <br />¢ a <br />J <br />a <br />r <br />M <br />z U_ <br />�V) <br />w <br />V o <br />rn <br />w <br />FE <br />O—� <br />W o <br />n <br />V LLn <br />M <br />r— <br />W J <br />E <br />x� <br />z <br />= w <br />U o y <br />¢ N 0 <br />• <br />o <br />w <br />Mn <br />J <br />< <br />a <br />Z <br />� <br />LL_ <br />Q E <br />z <br />zo <br />o 0 <br />> <br />< R <br />�z <br />oa <br />CKS <br />F— (O <br />R. <br />U <br />'°U <br />� <br />°z <br />N @ <br />ao <br />rz <br /><o <br />wz <br /><n <br />- <br />N <br />z � <br />W <br />m <br />Q <br />�z <br />N <br />3 <br />a <br />No <br /><o <br />�1 <br />�� <br />JZ <br />< <br />=3 <br />� <br />X0 <br />I� <br />O <br />w <br />is <br />V <br />zl¢ <br />8 3 <br />> Lo <br />L <br />� <br />rn <br />m <br />n� <br />W <br />� <br />c� <br />. � <br />ccc <br />I� <br />O <br />U <br />C� <br />I_- <br />m <br />N <br />a'' <br />a� <br />N N <br />n N <br />T <br />T <br />E <br />Z <br />E <br />a <br />f0 <br />IL <br />U � <br />Q p <br />JOB <br />NO: <br />20-8088 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />