ELECTRICAL SPECIFICATION <br />150A/2 <br />N DOOR <br />PANELL <br />CENTER <br />NOTES: <br />tll�t� <br />#,a copper to routs a outlets <br />ELECTRICAL CONTRACTOR <br />NEMA1 10 #12 copper to 20 amp ckts <br />I R <br />MUST VERIFY WITH THE <br />200 AMP( <br />#1copperto wH <br />l <br />'��/ <br />#,0.-3 coppertooryer <br />SPECIFICATIONS FOR THE TYPE <br />lAV <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />METER <br />SNOW <br />LOCATION PURPOSES. <br />MO <br />200 amp <br />/0 or 4/0 SER Alu <br />"� 2tt <br />150 amp <br />^ <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />} ® <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />K <br />TELEPHONE (OPTIONAL) <br />k<USB <br />TELEPHONE/USB (OPTIONAL) <br />N <br />TELEVISION (OPTIONAL) <br />N 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />R9 <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />GJ�J <br />ROUGH -IN FOR OPT. CEILING FAN <br />Q�12 <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G .r J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />UNDERGROUND 1DIsconnect KII <br />t <br />POWER CO. FEED A <br />/ U <br />INTERSYSTEM 4 Bare Cu Ground 'V � <br />BONDING 1 ' 1 44 GROUNDING WIRE <br />TERMINATION PE <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />i <br />OWNER'S SMITE <br />SCALE: NTS <br />12 <br />/ ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />/ / dVP OD. / <br />I <br />I <br />I <br />I <br />I <br />FAMILY RM <br />I / <br />I / <br />,' <br />G <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />M I <br />� I <br />PA PO 1� CAFE ,�� GFI <br />i <br />TPENDANT AS <br />PER SPECS <br />i <br />in \i <br />AC PAD i <br />WP H.B. <br />GFI DISC. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />U.C. OUTLET <br />FOR DW <br />U.C. OUTLET <br />RECEIPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H.B. <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4"=V-0" <br />ff� <br />i <br />-Lr-r <br />N <br />0 <br />CV <br />cfl <br />cti <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida <br />Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />F <br />Q <br />LO <br />o N E w <br />(h m <br />8 <br />V <br />0 <br />N N � J <br />C - ``J LL <br />2 '. cc, <br />mrn atw <br />t'j r r -o w R <br />v u_ a Y <br />N chi <br />tea U U_ a w <br />Z <br />sm_ O <br />k W <br />CZ,0 <br />.@ N to M O <br />0 ;; ¢ a <br />Z <br />a <br />a <br />L= <br />N <br />Cl) Z 2 N O <br />0 ') <br />ZLL <br />W <br />000 <br />N th <br />0 0 <br />z <br />d <br />E3 <br />GNV <br />O <br />v7 <br />W <br />C' <br />� <br />V <br />0 <br />w <br />s <br />in <br />w <br />�V) <br />rn <br />LJJ <br />t^ <br />J <br />m � <br />J. <br />U <br />c <br />o <br />to <br />oco <br />w <br />M <br />M <br />w o 5- <br />z <br />z <br />Z <br />_1 <br />ty- <br />c6E <br />E <br />0 <br />ca <br />O <br />O <br />O¢ <br />az <br />70 <br />U< <br />i <br />.0 <br />ao <br />o: � <br />a <br />c/) <br />� <br />Zz <br />Q Y <br />�m <br />m� <br />a <br />OZ LL <br />J <br />a <br />¢w <br />nowa <br />to <br />� <br />O ¢ <br />w� <br />z o U <br />rnw <br />vQa <br />o <br />aQ <br />�o <br />o <br />V <br />w <br />zI< <br />o� <br />U? <br />0 <br />C O <br />> Li') <br />L <br />m <br />/I1 <br />m <br />> <br />c° <br />M <br />NO <br />J <br />C) <br />0 <br />m <br />U <br />Cfl <br />N <br />r <br />T <br />M <br />N <br />.T� <br />_ <br />0 <br />r <br />LP)N <br />LO <br />1 I� <br />CV) <br />r <br />N <br />0 <br />z <br />z <br />10 <br />vi <br />ca <br />a <br />U <br />Q <br />p <br />� <br />JOB <br />NO: <br />20-8088 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />