My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39757 Harvest Creek Ln
Zephyrhills
>
Building Department
>
Building Plans
>
39757 Harvest Creek Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 3:06:12 PM
Creation date
2/19/2025 2:38:58 PM
Metadata
Fields
Template:
Building Plans
Street #
39757
Location
Harvest Creek Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
1587
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />3/8" CEMENT <br />PLASTER <br />12 MIL DRYLOK <br />CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />4 1) SEALANT AT <br />4) SEALANT JOINT <br />WINDOW BUCK TO <br />OUTSIDE EDGE OF <br />'' "' MASONRY <br />WINDOW BUCK <br />2) SEALANT JOINT <br />5) SEALANT FROM <br />:;, .'. '. INSIDE EDGE OF <br />WINDOW FRAME <br />WINDOW BUCK <br />ACROSS WINDOW BUCK <br />AND EXTEND TO <br />WINDOW FRAME <br />MASONRY <br />ATTACHED <br />PER CODE <br />6) TOOLED SEALANT <br />REQUIREMENTS <br />BEAD BRIDGING <br />CLADDING AND WINDOW <br />FRAME <br />3) SEALANT WINDOW FRAME T( <br />WINDOW BUCK ALL THE WAY <br />AROUND, INCLUDING SILL. <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />3/4" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />"V" SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />WEATHER <br />RESISITIVE <br />BARRIER <br />�"' WEATHER <br />✓E BARRIER & <br />iARILY SECURE <br />WOOD FRAME CONSTR. <br />EXTERIOR SELF -ADHERED FLASHIN <br />SHEATHING BY LAPPING DOWN <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOI: <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up &temporarily secure weather <br />resistive barrier above header to allow for <br />flashing installation <br />2. Self -adhered flashing plus head flashing under 1 <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head 2 <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW [WP01 <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />S <br />DO NO- <br />BOTTO <br />FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />FLmorlillu <br />F �n.�rniv <br />SCS 06 02 WINDOW FIN INTERFACE WITH SELF -ADHERED FLASHING <br />EXTRUDED SHOULDER DECK JOIST <br />SELF -ADHERED FLASHING 2xFRAMEWALL <br />PRODUCTS DETAILS TILE FINISH <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Refer to the number marked as O in each detail that corresponds to the <br />numbered items in the list of instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />1/2" DUROCK- <br />4SHING <br />2 <br />8 <br />WP04 <br />E <br />AM <br />WP07 <br />1'4' PER PLAN <br />V-0" PER PLAN <br />WEATHER RESISTIVE <br />BARRIER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4%1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL <br />SELF -ADHERED FLASHING <br />`� <br />\ <br />C <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF-ADHER <br />2 <br />u <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />/- DOOR ROUGH OPENING <br />WINDOW UNIT <br />SLOPE <br />FLASHING REQUIREMENTS <br />0.3 in : 12.0 in R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />- 3/4%1" BEAD OF CONSTR. (0.6 cm : 30.5 cm) include flashing as described in Section R703.4. <br />ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING <br />THRESHOLD OF DOOR AND <br />RETURN UP JAMB 6". USE LIQUID EXTERIOR R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of water <br />NAIL BRAND OR EQUAL WEATHER within the wall assembly b providing a water-resistant barrier behind the exterior cladding as required b Section R703.2 and a means of <br />PROOF CAULKING CEMT. FIN. y y p g 9 q Y <br />SELF -ADHERED FLASHING BUILDING PAPER draining to the exterior water that penetrates the exterior cladding. <br />WIRE LATH R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other <br />SUBFLOOR approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other <br />approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The No.15 asphalt <br />RIM JOIST felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building <br />appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based <br />sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The <br />2 O2 individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing (installed in <br />accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING <br />W P02 CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER WP03 Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT substantially nonwater-absorbing layer or designed drainage space. <br />INSTALL SELF -ADHERED <br />NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE <br />FLASHING JAMB & HEAD THROUGH SELF -ADHERED R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be applied <br />FLASHING, SEE FLASHING SELF -ADHERED FLASHING i f with th d i shingle -fashion or n accordance we manufacturer's instructions. Metal flashing sae corrosion resistant. Fluid -applied FLANGED WINDOW ��j g ghll biiFlipplied membranes <br />(SEE DETAIL WP01) used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to prevent the <br />SCORED entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER - Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />SELF -ADHERED FLASHING, ` _`o (BEFORE FOLDING, SCORE the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />EXTEND A MINIMUM 6" <br />RE ADHESIEASE PAPER VE AS W EXPOSE contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />VERTICALLY FROM <br />BOTTOM OF flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />THRESHOLD shall be installed at the following locations: <br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />2 shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following: <br />5 1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />4 manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details are <br />not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />1 6 sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent <br />2 drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />SELF -ADHERED FLASHING 1.3 1.3. In accordance with other approved methods. <br />W P05 INSIDE CORNER W P06 1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMANVDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />-7 Ground 3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />1 6.6.At wall and roof intersections. <br />Water Resistant Barrier 7.7.At built-in autters. <br />:LF-ADHERED FLASHING <br />kTC H <br />HERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />IWPO8 <br />8" CMU _ u <br />4" OR 8" CMU <br />(PER SEAT DEPTH) ___ <br />--- zQ z <br />FILL WITH GROUT =__ a <br />c a' •' LJ LU PLASTER STOP- <br />-- ° •a = CONTINUOUS BACKER - <br />-___ uJ ROD & SEALANT <br />SLOPED MUD BEDA. <br />_ W <br />VINYL SHOWER PAN F`=__ O A <br />-'- • • �4 U) <br />SLOPE- <br />--- ° e <br />a <br />4 Q d <br />Q a <br />SHOWER SEAT <br />WP1 1 <br />a <br />a <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />THIS GAP IS A RESULT OF <br />NATURAL SHRINKAGE. <br />DO NOT SEAL. <br />DRIP SCREED PLASTIC <br />ACCESSORY <br />SOFFIT/CANTILEVER <br />Lath <br />Sheathing <br />Stucco <br />WP09 <br />LEGEND <br />SELF ADHERED FLASHING (SAF) <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING,'OSB', PLYWOOD, DENSGLASS <br />kSTER STOP A <br />NTINUOUS BACKER ROD <br />EALANT <br />MENTITIOUS FINISH <br />RAL FRAMING <br />2AL SHEATHING <br />3AF <br />PLANE WRB <br />AK WRB <br />WP1 0 <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />- Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2"to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />C_ <br />to <br />Co <br />N <br />}. <br />� <br />O <br />O <br />C <br />co <br />-0 <br />a--� <br />M <br />Cf) <br />0 <br />C <br />0 <br />- <br />O <br />O <br />LL- <br />CU <br />O <br />CO <br />� <br />.N <br />_0 <br />O <br />O <br />0- <br />co <br />0- <br />.� <br />C/) <br />Q <br />a^)� <br />W <br />U) <br />(M <br />M <br />O <br />-0-.+ <br />o <br />U <br />O <br />C <br />CU <br />LLJ <br />Q <br />Z <br />Z <br />Q <br />J <br />SHEET NO. <br />WP1 <br />■ <br />0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.