My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39757 Harvest Creek Ln
Zephyrhills
>
Building Department
>
Building Plans
>
39757 Harvest Creek Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 3:06:12 PM
Creation date
2/19/2025 2:38:58 PM
Metadata
Fields
Template:
Building Plans
Street #
39757
Location
Harvest Creek Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
1587
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7 <br />Im <br />10'-0" <br />H..D <br />144 <br />qm <br />5068 SGID <br />30'41 <br />14'-8" 5'4" <br />LINE OF ROOF ABOVE NOTE: <br />—SEE SHEET S-11,12 '1873' <br />FOR LINTEL CALLOUTS & 9 <br />DETAILS < A7 <br />9 SH 35 LO <br />HD AT 7'-4" t HB <br />I <br />I <br />I <br />DINING ROOM CID <br />X 9'-5" FAMILY ROOM <br />8'-8" CLG 17'-11" X 13'-3" <br />8'-8" CLG I o <br />-4 3/4" 1,1'-11" i. S-1" 1. 6-9" A-9" L. T-8" L. 4'-8" <br />I <br />I (V <br />6" PLUMBING Q 2X4 KNEE <br />STACK WALL �, WALL, TOP I 00 <br />AT 34 1/2" <br />CARPETI <br />REF <br />TILE <br />DW <br />KITCHEN <br />I <br />o <br />SINK W/ <br />14'-1" X 9'-6" <br />8'-8" CLG <br />3 DISPOSAL <br />w <br />I <br />w <br />2068 <br />2 A7 ~ <br />Q <br />J <br />o <br />S6 <br />1 OOD/ RANGE <br />U <br />I <br />`� <br />PANTRY1 <br />(> <br />�� <br />i <br />-" <br />i <br />- <br />`F <br />16" <br />SH <br />- - - <br />co � 4 <br />-- <br />o <br />D4P <br />N <br />1 <br />whil IPDWR <br />R w <br />W/H 4" INSULATED <br />(20 <br />8'-8" CLG � a- �d, <br />�¢ G� <br />--- �- ` <br />BRG WALL MIN FIRE <br />PROTECTIVE <br />I -- <br />--- <br />D <br />S3 <br />� BOLLARD W/ WEATHER SRATED TRIP <br />gp� <br />LINE OF <br />FLOOR <br />4" INSULATED <br />ABA <br />BRG WALL <br />4LOV\ <br />1 <br />CC <br />10 <br />SLOPE[ <br />S3 <br />- <br />WALL <br />TWO CAR GARAGE <br />----- 8 ;� <br />20'-0" X 20'-1" <br />--- - <br />„ <br />H <br />7 <br />6 HIGI- <br />- --- <br />CONT <br />6 FOYER <br />RAILING <br />S3 <br />---- CARP <br />T <br />4 <br />-- -- <br />LINE OF GARAGE IN _ _ _ -----.----- <br />-- - 3 TILE <br />OPEN POSTION <br />2 1 00 <br />uj <br />11 <br />I� M <br />F <br />I <br />UP <br />H 1/2 341 D AT T-4 3 1/2' <br />� 00 <br />EMP.GLA S 0 M <br />2'-9" 4'_9" <br />16070 <br />FIRST FLOOR PLAN A <br />1 /4" = 11-0" <br />30'-0" <br />8" WD <br />I SOFFIT ABV <br />Co <br />ENTRY <br />8'-8" X 4'-4" <br />2'-8" T-8" 1,_0,. <br />8'-8" <br />9 <br />A7 <br />7 5/8" <br />_MA <br />J <br />S6 <br />00 <br />r, <br />M <br />0 0 <br />v v <br />m� <br />W_ <br />_Q <br />TIE BM <br />AT 8'-8" <br />280 <br />m 50 <br />W <br />F- Q <br />3 <br />A3 <br />v <br />co <br />a <br />N <br />NOTE: <br />PROVIDE R-11 F.G. INSULATION IN EXTERIOR WALLS, <br />INCLUDING BEHIND RIM JOIST IN FLOOR ASSEMBLY <br />PROVIDE R-11 F.G. INSULATION IN WALLS ADJACENT <br />TO ATTIC SPACE <br />NOTE: <br />1. SEE SHEET S-11 , S12 '1873' FOR LINTEL <br />CALLOUTS & DETAILS <br />2. ALL EXTERIOR HDRS AT OPENINGS ARE (2) 2X6'S <br />UNLESS NOTED OTHERWISE 9 <br />A7 <br />30'41 <br />LINE OF <br />ROOF <br />BELOW <br />27'-1 1/4" <br />2'-10 3/4" <br />DRAIN <br />1 <br />SH 25 <br />SHWR HD <br />I <br />HD AT T-3" <br />& VALVE <br />EGRESS <br />R & S <br />(4) 16" <br />I <br />v <br />- - - <br />DP SH <br />2068 BF <br />CV O <br />W <br />2668 <br />OWNER'S BATH <br />tY <br />6-87/8" <br />5'4" <br />�gW <br />0`O v <br />';> <br />4' <br />04 <br />FLR <br />LINE <br />TB <br />\ CD OWNER'S SUITE <br />N 14'-7" X 12'-8" <br />8'-0" CLGW.I.C.06 <br />G <br />TB° <br />WATER <br />S & R <br />CLO ET <br />- <br />1 -�C0 <br />R&S <br />-- -- <br />(2) 2068 BF <br />P <br />P <br />1 N <br />N <br />LOFT <br />I <br />I <br />14'-7" X 9'-1" <br />1 a, <br />BEDROOM #2 <br />AHU 8'-0" CLG <br />I K, <br />10'-11" X 10'-0" <br />A/C RETURN <br />8'-0" CLG <br />-UNDER DOOR <br />1 <br />M <br />LO <br />W <br />_¢0 <br />GS 1 <br />I <br />2'-10 3/8" 2'-10 1/2" <br />T-4 Jill <br />2'-11" V-2" 4'-10" <br />3'-8" <br />I 4'-11 5/8" M <br />4 1'-3 1/2" <br />2668 <br />W/S AT <br />6" 60" AFF <br />A <br />�22"x36"�_-_ <br />DN <br />UTILITY"'16 <br />-ATTI <br />� 2868 -- <br />- <br />42" H. co <br />6" p <br />- ACCESS <br />- - 4 ui 6„ L -- <br />-1 <br />Wow N <br />WALL <br />U <br />14 <br />- <br />BATH <br />0- <br />QA7 <br />#2r2668 <br />- <br />8 <br />-- <br />13 <br />- <br />42H�n7 <br />D <br />A7 <br />HA <br />SLOPED <br />TB <br />BOX -- <br />-11 <br />WOW <br />ALL <br />DRYER <br />10 <br />cv <br />R & S <br />2668 <br />VENT <br />�- <br />-- (2)2068BF-- <br />R & S - -- <br />- <br />N <br />-- <br />OPEN TO <br />(2) 2068 BF - <br />_-- 7 <br />BELOW <br />6 <br />36" H. iv <br />tC(04 <br />5 <br />CONT <br />(4 12' -- <br />- <br />RAILING <br />17� SH <br />4 <br />3 <br />Co <br />2 1; <br />°O <br />BEDROOM #3 <br />BEDROOM #4 <br />i `' - <br />10'-0" X 11'-1" <br />M <br />9'-10" X 9'-11" <br />8'-0" CLG <br />S6 <br />8'-0" CLG <br />It- <br />NP• <br />LRAME <br />I-3" <br />L34 <br />/ <br />WALL <br />SH25 <br />-------J <br />— <br />1- <br />HD AT 7'-3-N ` / <br />HD AT T-3" FRAME <br />EGRESS <br />EGRESS WALL <br />I <br />1 <br />5'-4 3/4" <br />10'-4" <br />5'-7 1 /4" <br />4'-4" 4'-4" <br />21'-4" <br />8'-8" <br />30'-0" <br />SECOND FLOOR PLAN A <br />1 /4" = 1 1-011 <br />A7 <br />INNEWS-1 <br />I <br />M <br />8" <br />FRAME <br />- WALL <br />v <br />0 <br />N <br />v <br />GENERAL NOTES: <br />ALL WINDOWS TO HAVE FLUSH SILLS. PITCH TOP SILL <br />FIN AWAY FROM WINDOW FRAME. <br />N <br />O <br />VERIFY ALL WINDOW AND DOOR ROUGH OPENING N <br />rn <br />SIZES WITH THE MANUFACTURER'S SPECIFICATIONS. a <br />INSTALL RND DRYWALL BEADS AT HORIZ & VERT "-" U <br />' o <br />CORNERS, EXCEPT AT EXT WALL OPENINGS OR AS 00 <br />NOTED. \ - <br />USE SQUARE CORNER BEAD AT DRYWALL NICHES & <br />REC CLG DETAILS; REC CLG SURFACES SHALL HAVE �,' ci w <br />SMOOTH FINISH. .r 2 <br />LOCATE ALL PLUMBING & EXHAUST STACKS BEYOND ,: ❑ <br />THE FRONT ELEV ROOF RIDGES, IF ALLOWABLE PER -' <br />CODE. ^, <br />,- W <br />ALL ANGLED WALLS TO BE 45' UNLESS NOTED z <br />OTHERWISE Q <br />THE GARAGE IS TO BE SEPARATED FROM ADJACENT <br />LIVING AREA AND ATTIC SPACE BY 1/2" GYPSUM BOARD <br />AND HABITABLE ROOMS ABOVE BY NOT LESS THAN 5/8" <br />THK. TYPE "X" GYPSUM BOARD (OR EQUIVALENT) > o 'U") u <br />APPLIED TO THE GARAGE SIDE. M <br />N V = _O0O u a <br />co <br />TOWEL BAR - (T.B.) = 56" A.F.F. u o <br />TOWEL BAR ABV. TUB DECK = 36" ABV. TUB DECK o if:8 o a <br />TOILET PAPER DISP. - (T.P.) = 20" A.F.F. N _ � 6 Q <br />ROD AND SHELF (SGL)- (R/S) = 60" A.F.F. .V "' aN <br />ROD AND SHELF (DBL)- (R/S) = 40" & 80" A.F.F. L o M °' <br />CORNER SHELF = 56" A.F.F. 7C) 0 o <br />MEDICINE CABINET - (M.C.) = 75" TO TOP OF <br />CABINET A.F.F. <br />WALL LEGEND: <br />ALL EXTERIOR WALLS TO BE CONSIDERED SHEAR <br />RESISTANT COMPONENTS. <br />8" CMU W/ 1X3 PT FURRING STRIP V, <br />R4.1 HIGH PERM 1/2" GYP <br />8" CMU (i <br />NON -BEARING 2X STUD W/ 1/2" GYP. <br />BEARING WALL 2X 16" O.C. w W w � w o z o <br />W/1/2"GYP. W W XM02�aoao <� 4 0 o <br />Q Q C_i In X <br />❑�0 ZLLLLOZ20❑~a¢ <br />FILLED CELL W/ 1 #5 VERTICAL Z)~ F- a w� 9 0 0 E 0 0 C08 C1 v <br />❑_ () O O O _jaa>zYOZZLLOw��a. <br />®= FILLED CELL W/(1) #5 TURNED 2'-0" INTO SLAB fn L Z ¢ o w O �_ 2 Y❑ 2 a❑ a. <br />Q <br />p= FILLED CELL W/(2) #5 VERTICAL o Q ❑ o ❑ a U_ <br />O = FILL CELL TO ONE COURSE ABV PIPE (NO REBAR) <br />p <br />STAIR DATA <br />STAIR O <br />RISERS TREADS LANDINGS TOTAL RISE f'V <br />MARK z W <br />A 16 AT 7 9/16" 14 AT 10" 1 1 U-0 3/4" 4 1 <br />SQUARE FOOTAGE: U-)C:)C)`M C:) <br />AREA PROPOSED Q M N <br />FIRST FLOOR LIVING 780 0- UO U_ V- <br />SECOND FLOOR LIVING 1090 Q W N <br />TOTAL LIVING SQ FT 1870 a ,M-•i <br />GARAGE 443 z U I <br />TOTAL SQ FT 2351 z <br />LU <br />INSULATION RE Q. W _' o <br />� <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2X4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2X6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />ALLOWABLE WIND SPEED DESIGN PREUREh (140 mph, enclosed, 3 sec. gust, 2.1112 to 6.9.12SSpitc, <br />Exposure C, Height=30 ft, Importance Factor-1.0, End <br />Zone= 4 ft) <br />As per Florida Building Code 7th edition (2020), <br />Residential Table R301.2 (4) (Wind Speed Conversions) CD 00 00 O O O <br />and ASCE 7-10 Methods co C) <br />r- e- N <br />C) CD CD CD O NO <br />WALL N N N N N N N <br />TRIBUTARY N 6 6 O O 00 CV A <br />AREA (ft)2 N O - - O O <br />INTERIOR END d ' 6 G O O N <br />0 0 0 0 o <br />10 39.4 -42.1 39.4 -51.8 O O <br />20 37.6 -40.5 37.6 -48.6 <br />` 0 0 0 0 0 0 <br />50 35.2 -37.3 35.2 -43.7 /L. CIj M � LO (D r_ <br />100 33.4 -35.6 33.4 -40.5 \ <br />/ <br />GARAGE DR 30.0 -33.9 30.0 -33.9 Z Z <br />Z C <br />� W V; <br />C:LIJ Q <br />a)Q Vo-c <br />-0 0 W LU <br />-0 Z CL W M Q <br />L LLI <br />r� = CO z <br />(D01=u <br />H _ Z <br />Q <br />>-2 <br />MZU <br />_ <br />Z Z LL <br />Ova22 <br />Ld <br />M <br />W <br />(1)Z Cr <br />Z <br />1-"1 <br />2 Q C <br />~ C: <br />` <br />2 <br />z <br />0 <br />0 <br />a <br />z <br />w <br />_j <br />ijjco <br />N <br />N <br />LAST PLOT DATE <br />o <br />Feb. 9, 21 <br />1 ST & 2ND FLOOR <br />Z <br />.__I <br />PLAN A <br />
The URL can be used to link to this page
Your browser does not support the video tag.