NOTES: <br />ELECTRICAL DETAIL: <br />A/C <br />DISCONNECT <br />WP <br />GFI <br />ELEC <br />METER <br />FIRST FLOOR ELECTRICAL PLAN A <br />1 /4" = 1'-011 <br />SECOND FLOOR ELECTRICAL PLAN A <br />1 /411 = 1'-0" <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF (GENERAL) <br />KITCHEN <br />BATHROOM <br />LAUNDRY ROOM <br />EXTERIOR WATERPROOF <br />GARAGE GENERAL PURPOSE <br />RANGE <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL <br />WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR TH <br />INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY THE <br />NFPA 72 2016 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER N.E.C. 210.8 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE <br />LEVEL NOT INTENDED AS HABITABLE ROOMS AND <br />LIMITED TO STORAGE AREAS, WORK AREAS, AND <br />AREAS OF SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP <br />SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPACLES ARE INSTALLED WITHIN 6 FEET <br />OF THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED IN LIVING <br />ROOMS, DINING ROOMS, SUNROOMS, FAMILY ROOMS, <br />DENS, LIBRARIES, SLEEPING ROOMS, PARLORS AND <br />SIMILAR ROOMS OR AREAS AS SPECIFIED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF MECHANICAL <br />FIXTURES ON PLANS AND THE ABILITY TO LOCATE THEM <br />IN THE FIELD MUST BE REPORTED TO THE ARCHITECT <br />PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS FRO GARAGE MUST BE SERVED <br />BY SEPARATE BRANCH CIRCUIT THAT DOES NOT SUPPLY <br />OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR. <br />NOTES: <br />EXTERIOR WINDOWS, SLIDING DOORS AND EXTERIOR <br />SIDE -HINGE DOORS SHALL BE TESTED AND LABELED <br />WITH A PERMANENT LABEL PROVIDING TRACEABILITY TO <br />THE MANUFACTURER AND PRODUCT. <br />200A INDOOR PANEL <br />CENTER <br />♦ #15 copper to lights & outlets <br />1 <br />00 AMP P <br />200 <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />O <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 <br />& 250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />INTERCOM SPEAKER <br />ALIGNED W/ EDGE <br />OF SWITCH <br />is <br />SWITCH <br />DOOR <br />JAMB <br />0 <br />4 1/2" <br />TRIM <br />BASE <br />TRIM <br />DUPLEX - <br />OUTLET 14 <br />M <br />0 <br />NOTE: <br />ALL DIMENSIONS ARE FROM <br />ROUGH FRAMING <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTAC <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONT <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />69 SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />--0 DIMMER SWITCH AT 36" <br />—� PUSH-BUTTON DOORBELL <br />ESA} CLG MNT LT FIXTURE <br />} CLG MNT PREWIRE - FIXTURE BY OWNER <br />-} SURFACE MNT FIXTURE <br />} WALL MNT FIXTURE <br />NOTE: <br />l TUB/SHOWERND OPALEX - ALTERNATCAN MAY <br />®� 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />�- APPROVED <br />RECESS CAN OR LED OWNER <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYE <br />F} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cM SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />=S-18- SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 — UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />� 24 -;a 24" VANITY LIGHTING <br />� 36 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />® EXHAUSTFAN <br />p DOUBLE FLOOD LIGHT W/ COVERS AND <br />U 150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />® CHIMES (DELETE W/ INTERCOM) <br />)� MASTER STATION <br />1!® ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR (W/ SIZE) <br />FEE A/C REGISTER <br />THERMOSTAT <br />12 SECURITY PAD <br />En ELEC METER <br />LES <br />AL <br />BE <br />BY <br />BALL <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE <br />USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION <br />PURPOSES. <br />0? 0 <br />0 �N <br />M w <br />�- co <br />CO <br />v <br />0 8 � Q <br />O O T ;tt <br />w a� c <br />CC) EM m <br />o i7 a <br />0 u.i uS w C 1- <br />LU <br />Q✓F-f (w dO�►-�wo-03-xLLUQwJ <br />w RO0000_jp nMai)LuW_ ¢ <br />Z0 <br />zaO62���W0O <br />IL <br />LL Ow Yz�¢ <br />LL C =O O�aLL <br />CM <br />N <br />N <br />O '0 <br />W <br />L <br />V <br />•ma) <br />v <br />Lo <br />LU <br />J <br />O <br />O <br />N <br />o"' <br />U0 = O <br />"D O <br />O <br />Q J Lr) <br />� V)LL <br />a a <br />< < 00 <br />Z I— <br />W <br />J 00 <br />c� M M o O o <br />T- c- N <br />0 0 0 0 0 0 0 <br />N N N N N N N <br />ob (V M <br />N O •-- r- O H O <br />4 6 6 O O N <br />0 0 0 0 O <br />c <br />0 <br />O O O O O O <br />.- N M 4 6 6 1-4- <br />W <br />Li <br />Q <br />z <br />z <br />g <br />15z <br />Q <br />00 <br />T—I <br />LAST PLOT DATE <br />Feb. 9, 21 <br />oz <br />W <br />U� <br />W I- <br />m0 <br />H H <br />z <br />z <br />z <br />Z Z <br />a� <br />rn z <br />2 Q <br />1 ST & 2ND FLOOR <br />ELECTRICAL PLAN <br />A <br />z <br />Z <br />w <br />0 U <br />