Laserfiche WebLink
RSH <br />ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT:5 25 ft <br />WIND SPEED (ULTIMATE) <br />140.0 MPH <br />WIND SPEED (ALLOWABLE) <br />108.4 MPH <br />EXPOSURE CATEGORY <br />C <br />EFFECTIVE <br />WIND PRESSURE AND SUCTION (PSF) <br />HIP ROOF >20 TO 27 DEG. <br />WIND AREA <br />(+) VALUE DENOTES PRESSURE <br />(SQ FEET) <br />(-) VALUE DENOTES SUCTION <br />[4:12]-[6:12] <br />a=oft <br />AREA <br />ROOF <br />1 <br />2e <br />2n <br />2r <br />3 <br />3e <br />3r <br />HIP <br />-35.94 <br />-49.57 <br />-49.57 <br />-49.57 <br />10 <br />GABLE <br />-38.22 <br />-38.22 <br />-60.99 <br />-60.99 <br />1 -60.99 <br />1 -78.58 <br />- - - -•---- -- <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />®' <br />d <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: <br />I (D <br />Q �® <br />SHINGLE: %fi' EXP. 1 (2%6) or 19/32" EXP. 1 (33/16) <br />1 <br />I ' <br />TILE: 1Y32" EXP. 1 (3�/16) <br />I I <br />I I <br />NOTE: <br />_+ <br />-� <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 %" x 0.113") NAILS <br />' 3r <br />3r <br />010 <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1%', SHEATHING SHALL BE FASTENED <br />") <br />,�,,aa <br />,�,,aa� <br />`" " <br />WITH ASTM F1667 RSRS-03 10d (2%" x 0.131 NAILS OR ASTM F1667 RSRS-04 (3"" x .120") NAILS <br />a=oft <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER <br />GABLE ROOF ]- 20 27 DEG. <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING <br />[4:12]-[6:1 2] <br />2] <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />UPLIFT CONNECTION CROSS—REFERENCE <br />MARK <br />SIMPSON STRONG TIE <br />USP MANUFACTURING, INC. <br />Q <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 - 10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 -10d x 1 1/2" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795 (2)PLY <br />9 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 -10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 - 10d x 1 112" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 10d x 1 112" <br />RT16A <br />1020 <br />1160 <br />9 - 10d x 1 1/2% 8-10d <br />H <br />FGTR <br />4725 <br />3400 <br />wl (18) 1/4" x 3" SIDS <br />WOOD SCREWS AND (2) <br />1/2" x 5" TITEN HD ACHOR <br />BOLTS <br />RFUS <br />7100 <br />--- <br />w/ (12) WS3 WOOD <br />SCREWS AND (4) 3/4" x 6" <br />WEDGE -BOLTS <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH. / (26) 10dx1-1/2" <br />HTT5 <br />5795 <br />5/8" ANCH. /(26) 10d x1-1/2 <br />K <br />HD313 * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />3295 <br />--- <br />2 - 5/8" DIA. BOLTS <br />L <br />VGT R/L <br />2225 <br />1600 <br />w/ (16) 1/4" x 3" SIDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />X 2 1/2" SIDS WOOD <br />SCREWS & (1) 5/8" ATR <br />M <br />VGT - F <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SIDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />x 2 1/2" SIDS WOOD <br />SCREWS & (1) 5/8" ATR <br />N <br />LUS26 <br />1165/1060 ** <br />1005/915 ** <br />8 - 10d x 3" <br />JUS26 <br />1000/1080** <br />- <br />8 - 10d <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 ** <br />20 - 16d x 3 1/2" <br />HUS26 <br />2035/3400 <br />--- <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 ** <br />1720/3125 ** <br />30 - 16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />- <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 - 10d x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14-10d x 1-1/2" <br />S <br />VGT - M <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND (1) <br />5/8" ATR EPDXIED w/ <br />SIMPSON SET w/ 12" MIN. <br />EMBEDMENT. <br />T <br />(2) LGT3 <br />6570-M 6960-F <br />4730-M 5010-F <br />w/ (24) 1/4" x 3" SIDS <br />SCREWS & (8) 3/8" x 5" <br />TITEN HD (2 PLY) OR (52) <br />16D SINKERS FOR FRAME <br />U <br />MGT <br />3965 <br />3330 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ SIMPSON "SET" <br />EPDXY <br />MUGT15 <br />4175 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ USP CIA-7000C <br />EPDXY <br />V <br />(2) LGT2 <br />4060-M 3770-F <br />3500-M 3240-F <br />w/ (32) 16D SINKERS & <br />(14) 1/4" x 2 1/4" TITENS <br />(2 PLY) OR (28) 16D <br />SINKERS FOR FRAME <br />LUGT2 <br />3100-M 4520-F <br />3100-M 3800-F <br />wl (32) 16D SINKERS & <br />(10) 1/4" x 3" WEDGE- <br />BOLTS (2-PLY) OR (32) 16 <br />SINKERS FOR FRAME <br />"X" <br />HTS 20 <br />1310 <br />1245 <br />24-10d x 1 1/2" <br />HTW20 <br />1530 <br />1285 <br />24-10d x 1 1/2" <br />SP1 <br />555 <br />535 <br />10-10d <br />SPT22 <br />735 <br />8-10d <br />SP2 <br />1010 <br />605 <br />12-10d <br />SPT24 <br />1090 <br />12-10d <br />HCP2 <br />590 <br />555 <br />12-10d x 1 1/2" <br />HHCP2 <br />1 680 <br />570 <br />1 (20)10d x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />*** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 12.02-20 <br />LOADS -- ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (8) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ('*). <br />INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 5'-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET S7 FOR ROOF FRAMING DETAILS <br />1 (2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />(A) <br />OR 2 PLY <br />;ARRIER <br />Z 2 PLY CARRIER —I <br />x CONT LEDGER <br />SEE SHEET S7 FOR <br />ROOF FRAMING <br />DETAILS <br />ROOF FRAMING PLAN - ELEV-B1 <br />SCALE: %4"=V-0" <br />r <br />pvvN <br />F\�y <br />r <br />3 r..tu <br />Fl- <br />°F°rir�E <br />v\N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />wn M <br />W <br />Q 'm Amok <br />PO <br />d' Epp 0 n <br />O 00 <br />M U N p',p <br />it <br />N O m10 J Il <br />0 <br />�n�°�LLa <br />M <br />a <br />0 0 <br />05 <br />�m0 u a �[ <br />co aL� <br />0 <br />Z <br />r m 0 <br />7 <br />L IL W <br />LW <br />1ow <br />- <br />'m N co LL O <br />U) aI °' 10 a a <br />n <br />N M Z W Ln O <br />Z <br />O V U N <br />❑ ❑ ❑ <br />z 04 M <br />N <br />(D <br />O � <br />z r <br />z � N <br />Q � <br />J <br />d <br />� <br />ti <br />M <br />c� <br />z <br />U' o <br />Cz <br />�4-1 <br />O <br />W O �y N <br />C) <br />W J <br />F— — E <br />L <br />= L � <br />cco�Q <br />Q <br />o <br />r� <br />o <br />M <br />J <br />z0 <br />w <br />z <br />L.L <br />_ <br />OE <br />E OU <br />z o <br />oo <br />i-. <br />> <br />¢� <br />zR <br />oa <br />CU <br />— E <br />O <br />a0 <br />X U <br />a¢ <br />o <br />00 <br />U <br />0 <br />oQ <br />dz <br />CV t <br />a� L <br />o <br />1. <br />¢o <br />m0 <br />C/) <br />N <br />J <br />oNo <br />0 <br />1, <br />z <br />¢z <br />EZ <br />rn <br />d <br />r� <br />z <br />go <br />son <br />U <br />o¢ <br />e0 <br />a <br />�w <br />k <br />o <br />a LL <br />w <br />= <br />7F, <br />;o <br />aF <br />V <br />zl¢ <br />00 3 <br />N p <br />J <br />> Lo <br />Om <br />CD <br />ca <br />ca <br />L <br />� <br />� <br />� <br />co <br />M <br />N <br />m <br />0 <br />O <br />U <br />C m <br />V <br />CD <br />U) <br />r <br />cc <br />I <br />T_ <br />2N <br />(fl C)Ln <br />r <br />m <br />a M <br />C N <br />rn <br />CV)N <br />r <br />o <br />Z <br />Z <br />c <br />E O <br />rri <br />c <br />a <br />cD <br />Q p <br />JOB <br />NO: <br />21-1073 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />7 <br />