My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39776 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39776 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:39:34 PM
Creation date
2/19/2025 2:39:36 PM
Metadata
Fields
Template:
Building Plans
Street #
39776
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
1636
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�i <br />0 <br />` J <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1 /2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1 /2" <br />602.0 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking ' <br />gap / <br />FILL CELL STD. 900 HOOK BOND BEAM <br />w <br />`t STD.90° BAR #5 <br />BAR CONT. #5 I HOOK BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />�T/BLOCKING <br />L <br />TO MATCH <br /># 2nd FLOOR <br />Solid block all posts from <br />above to bearing below. <br />U <br />STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. <br />2" <br />} Small gap 2" min. <br />max. � 4 max. <br />Clinch na <br />when <br />possible <br />4 <br />ils <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4 Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2" min. <br />g required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING �" GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />DOUBLE JOIST CONNECTION top flanguthcutst. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. hi <br />her i�nnlh <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* over squash=20 blocks and <br />Non -stacking walls wall or beam below.* <br />require additional <br />consideration. Check <br />local building <br />code for appropriate <br />details in One 10d box <br />areas=20 of high or=20 sinker <br />„ lateral load. nail each side <br />10 -0 at bearing. <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE 0 0 0 <br />5'-0" <br />STUB -OUT FOR 1'-O" o 0 0 <br />GAS METER 0 o to <br />c,4 <br />O <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-Y <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR 3)16d TOENAILS <br />2" X 12 16 O.C. <br />@ <br />19 -3 <br />1 SIMPSON HTS20 4 16d TOENAILS <br />() HSOOR() 0 S <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block / <br />(2x4 minimum) / <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —� <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" (lndl nails at 6" n.c. <br />U/ Provide adequate bearing <br />for each lapped joist. <br />Odnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />WE t <br />�� ❑ <br />1. 211 <br />6�� A 1%" ROUND HOLE MAY 6 6 DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1" <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 pif max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />Any 16" joist <br />12 <br />1'-0" <br />1'-1" <br />1'-2" <br />1'-2" <br />1'-3" <br />V-9" <br />2'-4.' <br />2'-11" <br />3'-7" <br />4'-2" <br />4'-9" <br />5'-4" <br />Span (ft) <br />16 <br />1'-0" <br />1'-1" <br />1'-2" <br />1'-2" <br />1'-T' <br />2'-&' <br />3'-2" <br />3'-10' <br />4'-9" <br />5'-7" <br />6'-4' <br />T-2" <br />20 <br />1'-0" <br />1'-1" <br />1'-2" <br />1'-2" <br />2'-0" <br />3'-0" <br />4'-0" <br />4'-10' <br />5'-11" <br />6'-11" <br />T-11" <br />8'-11" <br />24 <br />1'-0" <br />1'-1" <br />1'-2" <br />1'-3" <br />2'-6' <br />3'-T' <br />4'-9" <br />5'-10" <br />7'-2" <br />8'-4" <br />W-6" <br />10'-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Joist hanger <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series Depth End Intermediate <br />® <br />BCI5000s <br />9-112" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BCI 6000s® <br />BCI6500sw <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />5/8" 0 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) <br />NAILS T <br />R TRUSS <br />'OP PLATE <br />ice <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. — <br />Install tight to top flange. SLEEVE THRU STEM 4 <br />° <br />SEE PLAN FOR °• ° . • . ° <br />FOUNDATION INFO d' ° d' ° <br />STEM FOUNDATION <br />r GRADE _ nr-rr rr oar- nr a �r <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />e depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />�A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />��® LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° °° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4' 0" v <br />CENTERED @PIPE <br />PENETRATION <br />I a ' <br />4 c <br />•• <br />.. � <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />Q <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4' 0" <br />CENTERED @ PIPE <br />PENETRATION <br />—\ <br />4 <br />PVC OR SCH40 SLEEVE <br />r— PL <br />UMBING LINE <br />LU NG <br />d L <br />Al <br />• a 'd : d <br />z • a � .. <br />CO d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4' 0" PVC OR SCH40 SLEEVE <br />CENTERED @PIPE <br />PENETRATIONFF PLUMBING LINE <br />e G <br />° da G <br />iI d a P� ; <br />T IT <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />a <br />e�W V <br />�y C <br />W <br />CJ <br />Q.r <br />F 1,o t,l <br />.,°4 <br />�,�e��7 <br />E 1 i�,���•,� <br />@0F pSS <br />l i��Y 49SRCI�t i�, <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0 <br />W <br />a <br />I n <br />m� xr <br />o roiN <br />O (V J <br />C # u <br />0 <br />00 QC�7 <br />29 dl at u_ W <br />q <br />u-wa <br />M� LL a <br />Qj Y <br />� LL aLy <br />Z <br />M <br />'Is <br />.c my 0R <br />2 C� O <br />U) Q ¢ ¢ <br />z <br />CLW <br />IL <br />00 ci <br />L6 a <br />CN Z rn O <br />a <br />N <br />O U U � (D <br />W <br />Ell <br />V M � <br />z N M <br />o g <br />z <br />N <br />z � � <br />� <br />N <br />N <br />M <br />z .2 <br />tJ o <br />(U <br />4-J <br />W N <br />� <br />O— <br />w o <br />LnLn <br />c <br />U <br />W J <br />E <br />r 3 <br />z•"..A, <br />I <br />U 3 zK <br />° <br />c <br />W <br />M <br />J <br />o 5 <br />Q <br />ZE <br />L L <br />E: <br />n c <br />z a <br />o o <br />> N <br />O <br />EN U <br />�° <br />t� <br />20 <br />5C V <br />00 <br />7 U <br />� < <br />za� <br />U E <br />N � <br />z <br />wo <br />¢o <br />az <br />ire <br />L <br />m0 <br />oz <br />z <br />_I <br />�z <br />N <br />Cnz <br />r <br />OE <br />go <br />� <br />o� <br />"-z <br />W <br />J <br />o <br />w <br />�~ <br />�o <br />a LE <br />OU3 <br />z¢ <br />O <br />J <br />a <br />> Lo <br />N <br />rn <br />m <br />m <br />CD <br />L <br />� <br />c <br />cc <br />J <br />co <br />N <br />mD <br />V <br />/1 <br />I\ <br />� <br />z <br />_ <br />T <br />co CD <br />LO <br />T <br />N <br />M <br />CM N <br />o <br />M <br />Z <br />N <br />E <br />CID•- <br />m <br />Z <br />t4 <br />c <br />U <br />c <br />a- <br />Q <br />JOB <br />NO: <br />21-1073 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.