My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39776 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39776 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:39:34 PM
Creation date
2/19/2025 2:39:36 PM
Metadata
Fields
Template:
Building Plans
Street #
39776
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
1636
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br />> <br />tv <br />0 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI LIL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />I P <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />j4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />I.-..O <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />�--�— <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;Q <br />R. <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />FE9 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />FD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />N <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />MI <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />PANEL CENTER <br />UNDERGROUND IlDis <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />#14 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />or 4/0 SER Alu <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />Sj <br />P, ■ <br />PATIO <br />j11 /"I <br />� I , <br />,/ I I <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />H.B. <br />W.I.C. ):�' <br />--- — , -�� <br />I ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />I LIGHT PRE -WIRE <br />1 ` "/ <br />(%WNER'S <br />SUITE <br />I <br />SCALE: NTS <br />VERIFY METER LOCATION <br />WITH BUILDER <br />BEDR OM 2 L BtQROOM 3 <br />ROUGH -IN FOR / ROUGH -IN FOR <br />I f OPT. CLG. FAN/ ` / OPT. PRE FAN/ <br />ROUGH IN -�OR� I LIGHT PRE-WIR� 12/ 12 <br />OPT. CLG. AN! !h I <br />LIGHT PRE- IRE / <br />141 <br />/ 1 PED�ObM 4 <br />\ S.D S.D. <br />DEDICATED RECEPTACLE 3 <br />O FOR MICROWAVE RANGE C.M <br />HOOD PER SPECS --- / HALL7 — <br />---------- — — / C.M S.D ---------------- <br />O <br />771 <br />----RANGE <br />(17 7C17fEt <br />Ili <br />— .-C: W1�Gki <br />F R IS I OS <br />I DW I <br />I <br />If----- <br />I © —L_ L� <br />I � <br />C.M <br />I <br />II <br />ROUGH -IN F�R <br />OPT. CLG. F-- N/ LIGHT <br />PRE -WIRE <br />I <br />/ FAMILY ROOM <br />i <br />NSINKw/• <br />TDISP <br />I <br />-----------CH <br />PENDANT AS <br />PER SPECS <br />ii CAFE <br />i <br />i <br />i <br />i <br />i <br />i <br />VGFI @ 44" <br />A.F.F. <br />_ z I <br />I Q d I <br />O U I <br />I <br />WU I <br />� J <br />w 2-CAR GARAGE <br />GFI@44" <br />A.F.F. <br />VP / GARAGE 1 I <br />LIGHT AS IGARAGE <br />PER SPEC (DOOR <br />IGFI <br />T. OPT _ — <br />' W. <br />I <br />r A- - <br />I A I <br />At <br />l l I I <br />I I <br />I <br />L------------ <br />GFI @ 44" A.F.F. <br />IRRIGATION <br />H,B. <br />'trWP I <br />GFI <br />ENTRY <br />I <br />I <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4"=1'-0" <br />i <br />N <br />0 <br />N <br />CO <br />CV <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />fA <br />Q <br />'�t E <br />O M 8 <br />$ <br />m r- <br />N r at <br />U <br />CR <br />0 C' <br />LL <br />® <br />N <br />O N <br />* L. W <br />n <br />tnr-I-L <br />LL W <br />a Y <br />a <br />eiMv � <br />J LL LL <br />(L <br />Z <br />0 0 <br />_ <br />O <br />15E ,Z; <br />=O� <br />ILf6C�_� <br />Z <br />IL <br />N 04 Z <br />a <br />L O <br />ZO <br />U <br />U_j N <br />W <br />o00 <br />v <br />Z N M <br />o g <br />zOD <br />zCD <br />CD <br />J — <br />�^ LL1 <br />r.. <br />N <br />z a <br />cn o <br />LU cc <br />� a <br />U <br />m <br />O� <br />w o <br />(� <br />r— in <br />v� <br />I <br />W J <br />p <br />U <br />LpEEly <br />L `R 0® <br />¢ cc <br />0 <br />0 <br />N <br />I� <br />o <br />w <br />co <br />coo <br />z <br />J <br />o <br />QQ <br />¢S <br />a <br />E O <br /><_ <br />?® <br />N <br />f— O <br />28 <br />UO <br />O E <br />tV <br />L <br />a p <br />¢o <br />< <br />a Z <br />�w <br />U 3 <br />o <br />z <br />oy <br />U <br />m o <br />O LL <br />Z <br />J <br />�z <br />M <br />m 3 <br />1.1 <br />0< <br />ao <br />�w <br />o <br /><¢ <br />)O <br />co <br />d <br />Z < <br />Oa ~ <br />U <br />O <br />>L <br />J <br />m <br />N <br />ccc <br />L <br />� <br />� <br />o <br />M <br />O <br />Q <br />U <br />m <br />L <br />f^ <br />V/ <br />c <br />r <br />r'4.. <br />c� O <br />LC) <br />r <br />Z <br />r N <br />r <br />E <br />M <br />M N <br />o <br />ccN <br />tri <br />r <br />Z <br />Z <br />E O <br />c <br />FL <br />U J <br />Q p <br />c <br />J <br />JOB <br />NO: <br />21-1073 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.