(2) 2x6 OR (2) 2x8 <br />TOP PLATE SEE <br />PLAN <br />1/2" MINIMUM CEMENT FINISH <br />(2) 2x HEADER TO SIT <br />2x6 / 2x8 WALL BEYOND <br />FLUSH TO THE OUTSIDE <br />STANDARD 3" DIA. TEE <br />SEE PLAN FOR HEADER <br />SEE PLAN FOR SIZE <br />THREADED 3" DIA. EXTENSION <br />CONNECTION <br />SCREW OFF CAP (3" DIA.) <br />2x DEAD WOOD @ MID <br />FOR CLEAN -OUT <br />POINT w/ (3)12d <br />MIN. EXTENSION FROM <br />DOUBLE 2x TOP <br />TONEAILS SPACED <br />EXTERIOR FACE BLOCK <br />EVENLY <br />WALL IS 1 1/2" MAXIMUM <br />VENT OR 2ND FLOOR <br />TYPICAL C.M.U. WALL <br />3/4" FURRING STRIPS <br />1/2" GYPSUM BOARD <br />W/ DRYWALL SCREWS <br />@ 8" O.C. OR 4d <br />DRYWALL NAILS <br />PLATE INTERIOR <br />HEADER FLUSH TO OUTSIDE OPTION EXTENSION FROM EXTERIOR WALL <br />FACE OF BLOCK WALL IS 21/4" <br />2x BLOCKING @ EACH END W/ 10d @ <br />4" O.C. FROM EACH HEADER FACE <br />TO BLOCKING <br />(2) 2x HEADER <br />PER PLAN <br />2x BOTTOM PLATE W/ (1)10d @ 8" <br />VARIES O.C. TO EACH HEADER FACE <br />2 x 6 (MIN.) FRAME <br />WALL HEADER DETAIL 1 <br />SCALE: N.T.S. SL� <br />12 <br />SEE TYPICAL WALL SECTION <br />(TYp) SEE ELEV. <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />DOUBLE 2x4 SPF. #2 <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />SINGLE 2x CONT. TOP <br />PLATE W/ (2)12d INTO <br />TRUSS ABOVE <br />2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />SIMPSON SP2 w/ (12) 10d <br />(3) 10d TOENAILS T&B <br />NAILS AT EACH STUD <br />AS REQ'D <br />2x BLOCKING @ MID <br />POINT EVERY OTHER <br />* STUD W/ (3)10d NAILS <br />i+ f <br />CRICKET AS REQUIRED <br />SINGLE 2x CONT. BASE <br />PLATE W/ (2) 16d TO <br />TRUSS BELOW <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C <br />EDGES & 8" O/C FIELD <br />SIMPSON SP1 w/ (10) 10d <br />NAILS AT EACH STUD <br />2x P.T. PLATE <br />5/8" x 10" "J" BOLT @ 24" O/C MAX <br />W/ 8" EMBEDMENT <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />AND FILLED SOLID W/GROUT <br />1 #5 VERT. IN CONC. FILLED CELL W/ <br />STD. 90" HOOK IN K.O. BLOCK <br />KNEE WALL ABOVE MASONRY WALL DETAIL <br />MOUNTING BASE NOT SHOWN <br />FOR CLARITY SEE DETAIL <br />K/S4 <br />SEAT FOR BLOCK IS POURED <br />IN PLACE CONCRETE <br />GARAGE FLOOR SLAB <br />TROWEL FINISH SEE <br />GENERALNOTES <br />SLOPE FORWARD <br />FOR DRAINAGE <br />BLOCKING (TYP.) <br />L-ROOF TRUSS <br />UPLIFT CONNECTOR (SEE SCHEDULE) <br />MOISTURE BARRIER <br />SCALE: N.T.S. <br />SEE PLAN FOR FOOTING _ <br />DIMENSIONS <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />SCALE: N.T.S. <br />TO DRAIN C- <br />EXTERIOR <br />WALL <br />WALL CLEAN -OUT rA <br />SCALE: N.T.S. S4 <br />1ST COURSE 2ND COURSE 3RD COURSE <br />MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COURSE MUST BE BONDED TO THE <br />REFER TO WINDOW PRODUCT APPROVAL COURSE BELOW. EVERY THIRD (3RD) COURSE THE 11" DOOR JAMB WALL IS TO BE <br />SHEETS FOR INSTALLATION INFORMATION BY WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. <br />MANUFACTURER. <br />TYPICAL SECTION THRU WINDOW g MASONRY LAYOUT rD <br />S4 SCALE: N.T.S. St� <br />7 5/8" 8" 7 5/8" 8" 7 5/8" 8" <br />KNOCK_OUT NOTCH LINTEL WHERE REQUIRED <br />BLOCK W/ (1) #5 FOR CONCRETE PLACEMENT 7 <br />d <br />, <br />4 <br />o <br />„ d <br />8" STD. WHOOK 8" <br />LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS <br />GREATER THAN 6'-0" WIDE (U.N.O. ON <br />PLAN) <br />OPENING <br />FILLED CELL W/ (1) #5 VERTICAL <br />SEE FDN. PLAN FOR LOCATION <br />_- <br />- <br />NOTES: <br />lO FILL LINTEL AND ALL CELLS ABOVE LINTEL. <br />NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION <br />PORT <br />@ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. <br />Q VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />PROPERLY. <br />O3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />® OPENINGS LESS THAN OR EQUAL TO 6'-0" IN WIDTH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />TYPICAL FILLED LINTEL ASSEMBLY <br />SCALE: N.T.S <br />G <br />S4 <br />WIDTH OF OPENING VARIES 4„ FORM CONCRETE INSET TO <br />112"X9 1/2" PLYWOOD CREATE A SOLID BASE FOR <br />SCRAP MATERIAL BLOCK WALL ABOVE. <br />J <br />\ 2 <br />w <br />NExEINNER > <br />d" <br />FORM CREATES CONCRETE RECESS TO <br />2X4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />MOUNTING BASE SHOWN <br />IN POSITION GARAGE ENTRY FORM DETAIL <br />2x6 MOUNTING BASE <br />j <br />�8x8x16 C.M.U. GARAGE DOOR_ <br />j% <br />GARAGE DOOR ROLLER <br />CONNECTION ASSEMBLY <br />..,' GARAGE FLOOR <br />TRAVEL DIRECTION OF <br />GARAGE DOOR <br />MOUNTING BASE DETAIL <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />TRACK MOUNTING BRACKET <br />GARAGE DOOR TRACK <br />a <br />POURED CONCRETE BASE FOR BOTTOM OF MOUNTING BI <br />BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />SHED FORWARD THIS DRAWING. <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />N <br />2x CRIPPLES @ --� <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />SIMPSON SP4 w/ (6) <br />10d x 1 1/2" AT EA <br />STUD (USE SP6 FOR <br />2x6 WALL, USE SP8 <br />FOR 2x8 WALL) <br />10d NAILS @ 8" <br />O/C TYP. <br />DOUBLE 2x <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />SOLID AREAS ARE <br />STEEL AND GROUT <br />FULL 8x8x16 BLOCK <br />DOOR OPENING <br />VERTICAL JAM <br />5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />NOT TRANSFER LOAD. <br />2x6P. <br />J-BOLT <br />TRACK <br />BRACKET <br />fOP <br />3 <br />iARAGE <br />IOOR <br />W/MOUNTING ANGLE <br />NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. <br />TYPICAL GARAGE DOOR BUCK K <br />SCALE: N.T.S. S4 <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />SIZE <br />EA END <br />EA END <br />EA END <br />EA END <br />SIMPSON <br />1'-4' <br />(1) <br />(2) <br />(1) <br />(2) <br />(1)LSTA30 <br />4' - 9' <br />(2) <br />3 <br />(2) <br />(2) <br />(1) LSTA30 <br />T -16' <br />(3) <br />(4) <br />(2) <br />(4) <br />(2) LSTA30 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT <br />OVER TOP PLATE ** HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 12d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />@ 12" O/C FOR 2"x10" OR <br />GREATER HEADER <br />1 (2) 2x HEADER SEE PLAN <br />S4 INTERIOR HEADER: <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />BOX HEADER • EXTERIOR HEADERS: <br />ONLY (1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(2) 2x SILL PLATE w/ SIMPSON <br />LS30 w/ (6)10d x 1 1/2" EACH <br />SIDE <br />2x STUDS TYP. <br />00 SIMPSON HTT4 TYP. <br />Op OiQ U.N.O. SEE N/S4 <br />HOLD DOWN <br />CONNECTIONS <br />NOT REQUIRED @ <br />P.T. BOT. PLATE BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />WALL HEADER DETAIL rQ <br />SCALE: N.T.S. S4 <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />12 TRUSSES @ 24" O/C <br />(T SEE ELEV. UPLIFT CONNECTOR (SEE <br />SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM <br />C. 926 APPLY 3 LAYERS W/ <br />TOTAL THICKNESS 7/8" OVER <br />METAL LATH. FIRST 2 LAYERS <br />3/8" THICK EACH. 3RD LAYER <br />1/8" THICK OVER WATER <br />RESISTIVE BARRNE <br />SIMPSON SP2 w/ (12)10d <br />NAILS AT EACH STUD <br />TRUSS BOTTOM CHORD OR 2x4 <br />1/2" EXTERIOR GRADE SHEATHING <br />CRICKET AS <br />BLOCKING W/ 2-16d TOE NAILS <br />@EACH END <br />FASTENED TO TRUSSES WITH 8d <br />REQUIRED <br />COMMON WIRE NAILS @ 4" O/C <br />BOUNDARIES 6" O/C EDGES & 8" <br />BLOCKING ( ) <br />v <br />0/C FIELD <br />a <br />2x TOP PLATE <br />T <br />2X4 PT STUDS @ 16" O.C. <br />2-16d NAILS @ 24" O.C. OR <br />(2) 2X4 PT STUDS UNDER HIP <br />EQUAL TO TRUSS BOTTOM <br />CARRIER/GIRDER TRUSS <br />= _ = <br />CHORD OR BLOCKING <br />SIMPSON HETA20 w/ (8)10dx1 1/2" <br />NAILS AT EA. TRUSS VERTICAL WEB <br />2x STUD @ 24" <br />(24" O.C. MAX) w/ MIN. 4" EMBEDMENT <br />I <br />L <br />O.C. MAX. <br />PROVIDE P.A.F. NAILS OR <br />IN KO BLOCK AT EA. STUD <br />MAIN SPAN <br />2x P.T. PLATE <br />EQUAL @ 12" O.C. <br />MOISTURE BARRIER <br />ROOF TRUSS <br />SEE A/S3 FOR 7 <br />STAGGERED FROM BOT. <br />UPLIFT CONNECTOR <br />REINF. INFO. <br />\\UF <br />PLATE TO CONCRETE <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />(SEE SCHEDULE) <br />AND FILLED W/ GROUT <br />1 #5 VERT. IN CONC. FILLED CELL <br />W/ STD. 90' HOOK IN K.O. BLOCK <br />ALT. KNEEWALL ABOVE MASONRY WALL DETAIL <br />SCALE: N.T.S. <br />- PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />PSPN516Z w/ (12)16d NAILS <br />TOP 2 ROWS 10d @ 3" O.C. (14 <br />SPLICE NAILS TOTAL) EA. SIDE OF <br />• 48.,�PLICE STAGGERED <br />N <br />C; 10d @ 8" O/C <br />O�STA. <br />ATTACH ALL J <br />EXTERIOR STUDS <br />W/ 4b16d TOENAILS <br />TO P PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />OVER STUD <br />AT LEAST 4'-0" LONG. TYPICAL <br />TOP PLATE SPLICE DETAIL M <br />SCALE: N.T.S. <br />F= 2240 LEIS <br />SIMPSON SIMPSON SIMPSON C <br />SP4 SP2 SIMPSON SP4 SP2 <br />k. <br />12 <br />2X STUDS @ 24" O.C. <br />/8"x10" "J" BOLT <br />@ 24" O.C. MAX. <br />MIN. (2) PER <br />BOTTOM PLATE <br />SECTION 2X P.T. <br />PLATE <br />N SP4 <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 AND <br />BB/S1 FOR ADDITIONAL <br />DETAILS <br />RECESS <br />LINTEL <br />d <br />\-NAILED <br />INTO <br />• <br />TRANSOM <br />TRANSOM FRAMING <br />FRAMING <br />SEE SECTION AA/S1 <br />AND BB/S1 FOR <br />ADDITIONAL DETAILS <br />SIMPSON <br />SP1 <br />SIMPSON <br />SIMPSC <br />L TELS <br />SP4 <br />SP4 <br />IS <br />SIMPSON SIMPSON <br />SP4 SP2 <br />r <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP1 SIMPSON <br />SIMPSON SP4 <br />SP4 <br />TYPICAL INTERIOR NON - <br />BEARING WOOD FRAME WALL <br />SIMPSON SP4 <br />�2X <br />TOP PLATE <br />OVERLAPPING <br />`10d NAILS @ 6" <br />STAGGERED <br />J-BOLTS @ 24" O.C. <br />MAX <br />—2X P.T. PLATE <br />d 2X8 P.T. BOTTOM P TE p <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. B <br />C (MIN. (2) PER BOTTOM PLATE) <br />SIMPSON <br />SP4 <br />10d NAILS 4" <br />SCALE: N.T.S. S4 <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />SPF) <br />(3075# SPF) <br />3 (4565# SPF) <br />3 (5645# SPF) <br />3 (6970# SPF) <br />)S (9335# SPF) <br />IN. 8" <br />PDXIED A.T.R. <br />i&NUT <br />'OXIED A.T.R. <br />i&NUT <br />OXIED A.T.R. <br />i&NUT <br />C <br />0 <br />/E <br />KING <br />6d TOE NAILS <br />BLOCKING <br />WALL ABOVE <br />RY <br />). BLOCK W/(1) <br />FONT. & <br />LED <br />10" J-BOLTS <br />0" O.C. <br />rvrnjONRY WALL <br />/ STAGGERED A 10d NAILS @ 6" O.C. <br />S G <br />' a <br />2X8 P.T. BOTTOM <br />PLATE <br />D <br />5/8"x10" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />TAG ERED <br />TRANSOM FRAMING <br />0 o BEYOND. <br />-PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" PLYWOOD <br />O/C BOUNDARIES 6" O/C EDGES o E SHEATHING <br />& 8" O/C FIELD <br />S4 <br />B <br />• SIMPSON SP4 w/ (6) 10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2x8 WALL) o SHEATHING <br />• SIMPSON SP2 w/ (12) 10d NAILS MASONRY <br />• SIMPSON SP1 w/ (10) 10d NAILS WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. <br />MAX. (MIN. (2) PER BOTTOM <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE- ENTRY rR� <br />SCALE: N.T.S. <br />N <br />�, <br />- <br />< troy r• <br />�3S1 <br />��'lllllllll6111,��'�'>> <br />�\ <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal Is only for <br />the structural englneedng portions of the drawing pages bearing <br />Engineers signature and seal. <br />H <br />q00 <br />$ E r <br />M 8 r # <br />g <br />0(0nro <br />0, <br />R. <br />LL <br />a <br />' <br />a <br />(n C-, W <br />O 22S LL d <br />r <br />[3 <br />� LL U_ S d <br />Z <br />- <br />r m 5 <br />0oUj <br />W <br />�9 <br />M ¢�a <br />Z <br />I <br />N M Z N O <br />= <br />O U Q _j (0 <br />rr W <br />❑❑❑ <br />z <br />r $ <br />z C> <br />J— <br />n v, <br />v1 <br />zC1 <br />4-1 <br />.0 <br />— lL <br />cn � <br />o <br />�' <br />W $ <br />in <br />U <br />U <br />c <br />0 <br />soy <br />r` <br />o <br />w <br />z <br />M <br />w� <br />o <br />0. <br />?• <br />Q <br />E U <br />Co <br />V <br />oa4 <br />V J <br />z <br />_ <br />0r <br />n� <br />N � <br />po <br />p <br />� <br />m- <br />z <br />_E <br />) <br />Y <br />U <br />No<w <br />g <br />J <br />a° <br />z0 <br />W <br />a3: <br />�w <br />a� <br />o <br />O <br />< <br />�o <br />o� <br />2 Q <br />o- <br />V <br />�O <br />> I.C) <br />J <br />m <br />^, <br />W <br />CU <br />.> <br />c <br />O <br />fj <br />N <br />0 <br />U <br />CO <br />= <br />O� <br />T <br />0404 <br />r <br />C)� <br />T <br />m <br />N <br />cY <br />o <br />z <br />E O <br />E <br />.o °3 <br />a <br />U <br />Q p <br />c <br />JOB <br />NO : <br />20-8085 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S4 <br />