My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39812 Harvest Creek Ln
Zephyrhills
>
Building Department
>
Building Plans
>
39812 Harvest Creek Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 4:04:27 PM
Creation date
2/19/2025 2:41:17 PM
Metadata
Fields
Template:
Building Plans
Street #
39812
Location
Harvest Creek Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
1644
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DOOR JAMB (REFER ix4 1/2" DRYWALL DOOR JAMB (REFER 1x4 1/2" DRYWALL DOOR JAMB (REFER 1x4 1/2" DRYWALL <br />� <br />MAX. 8" � UNACCEPTABLE INSTALLTION � <br />TO PRODUCT P.T. TO PRODUCT TO PRODUCT <br />APPROVAL FOR CONN. <br />PROPER INSTALLATION DO NOT DO THIS <br />2"x BOT. PLATE W/ (2)10d @ 6" O.C. <br />J'' <br />APPROVAL FOR CONN. 1 X 4 <br />APPROVAL FOR CONN. / : 1x4 ;' <br />#5 REBAR (TYP,) <br />3/4" PLYWOOD DECKING GLUED <br />ATTACHED WALL SHEATHING TO <br />1x4 P.T. 3/16"0 X 3" LONG / FURRING <br />FURRING (2) ROWS 3/16 x 3-1/2 <br />3-1/4" LONG X 3/16"0 ,' FURRING <br />#5 REBAR ` <br />AND NAILED W/ 8d COMMON <br />-"_ <br />6" O.C. EDGES AND 12" O.C. FIELD <br />2X BOTTOM PLATE W/ 8d @ 4" <br />O.C., 2 ROWS STAGGERED <br />TAPCONS <br />TAPCON. INTO TAPCON @ 16" O.C. & 4" 2Xg <br />STAGGERED @ 16" <br />(TYP,) <br />♦ '' <br />1x8 P.T. FROM EACH END w/ MIN. 1X8 <br />BLOCK@ SPACING 1' O.C. 2-ROWS INTO <br />1 DETAIL 2" EDGE DIST. ATTACH <br />- <br />PER MANUFACTURE MASONRY THROUGH '� _ 1 I2" DETAIL 1 x8 w/ (2) ROWS 8d NALS �� <br />3 DETAIL <br />1 D. 90- HOOK (TYP.) <br />STD. so^ ` <br />_ . <br />2x BAND JOIST W/ FACE NAIL 10d <br />@TOP 8 BTTM CHORD, AND (8) <br />1x4 P.T. & 1x8 P.T. STAGGERED @ 12" O.C. <br />FILL SOLID HOOK (TYP.) <br />BOTH CELLS <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />3/16" x 3 -1/2" DOOR JAMB (REFER <br />TAPCON @ 16" 1x4 P.T. TO PRODUCT <br />METAL SEAT PLATE <br />O.C. & 4" FROM DOOR JAMB (REFER YWALL <br />% j , <br />APPROVAL FOR CONN.rlx4l/2"DI <br />EACH END W/ MIN TO PRODUCTNOTE: <br />j <br />LAP SHEATHING TO <br />DOOR JAMB (REFER*7,'EDGE <br />TO PRODUCT DIST. APPROVAL FOR CONN. %'/ 2x8 P.T. w/ (2) ROWS 3/16" <br />%j� x 3-1/2" TAPCON @ 16"1x4 <br />/i; <br />♦ <br />BOTTOM OF BAND <br />JOIST TYPICAL <br />APPROVAL FOR CO <br />(2) ROWS 3/16 x 3-1/2 / O.C. & 4" FROM EACH <br />�01 TAPCON @ 16" O.C. & END w/ MIN. 2" EDGE DIST.FURRING <br />4" FROM EACH END w/ <br />+2,. NOTC @ FIRST COURSE@2x8 <br />SIMPSON HGAMIOKTA 12" O.C. <br />P.T. ATTACH SECOND PLY w/ <br />' � <br />w/ (4) 1/4x1 1/2" SDS SCREWS <br />..AS REQ'D MIN. 2" EDGE DIST. (2) ROWS 10dx3° x <br />I ♦ <br />INTO BAND JOIST & (4)1/4"x2 3/4" <br />2x DETAIL 2 1 /4" DETAIL STAGGERED @ 12" o.c. 3-1 /4" DETAIL <br />NOTCH WEB AT THE <br />' <br />t5^ FIRST 2 COURSESFILLED <br />- <br />TITEN INTO K.O. BLOCK <br />BUILDOUT OVER SIZE DOOR -WINDOW ROUGH OPENINGS �cc <br />CELL PER <br />FOUNDATION PLAN <br />FILLED CELL INSTALLATION H <br />RETROFIT FOR MISSING <br />EMBEDDED STRAP <br />SCALE: N.T.S. SS <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. <br />INFO SCALE: N.T.S. <br />SCALE: N.T.S. <br />SS <br />2x8 P.T. BUCK -CONNECT TO BLOCK SECTION <br />A_A <br />UPLIFT CAPACITY = 805 # FOR 1 STRAP <br />W/ 1/4" x 31/4" TAPCON ( 1 1/4" MIN. <br />= 1610 #FOR 2 STRAPS <br />' . FILL 1st 4 COURSES <br />EMBEDMENT INTO BLK.) 1/4" MAX <br />8" <br />SOLID WIGROUT <br />1 X 4 FURRING SOLID BLKG. AT TOP BTWN. <br />1/4" x 31/4" TAPCONS <br />1 PLY PRE-ENGINEERED TRUSS <br />BLOCK HEADER ARCH BLKG. & BUCK <br />SIMPSON HM9KT w/ (4) 1/4"xl 1/2" SDS <br />1/2" DRYWALL * <br />SCREWS & (5)1/4" x 2 1/4" TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 wl (16) 16d <br />8d NAILS AT 8" O.C. AT BUCK <br />SINKERS AND (7)1/4"x2 1/4" TITEN = 2150 #) <br />2 x 8 45^ DIAGONAL (4)10d NAILS INTO <br />LEAVE A CUT OUT IN O.S.B. ON THE <br />BRACE(S) 2 x 8 BRACE! BLKG. <br />INSIDE TO ALLOW FOR INSULATION <br />7/16" OSB <br />TO BE INSTALLED <br />BOND BEAM OR CAST IN PLACE BEAM <br />FOR OVERHANGS BETWEEN OVER 1 1l2" <br />BUILT UPPLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />POLY CELL IN THIS AREA <br />2 x 8 45 DIAGONAL BRACE AT EA. <br />coNracr ENGINEER of RECORD FOR <br />FURTHER INSTRUCTIONS. ' • r <br />SCRIBE (NOTCH) <br />FACE OF ARCH W/ (3)10d NAILS <br />•• <br />OVERHAN �' <br />BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 <br />AT EA, END <br />RETROFIT TRUSS DETAIL <br />, <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />N.T.S. <br />• <br />INSTALL WDW. SCREW ANCHO 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />ARCH FACES W (4) 10d NAILS THRU OSB INTO 2 x 8 <br />PROVIDE TAPCON WITHIN <br />' <br />RETROFIT WALL OVERHANG DETAIL (NTS) <br />INTO ARCH BLKG. PER <br />A OR THRU <br />4" MIN. OF BRACE <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" <br />INSTALLATION DETAILS -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />TRUSS AS SHOWN FOR O.H. UP TO 2'-6" <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />IF TRUSSES USED W/ 3 #6 X 4'%" WOOD <br />) () <br />' DOUBLE 2x4 SCAB FOR Z-6" TO 4'-1 O.H. <br />NOTE: FOR OVERHANGS LESS THAN 3l4" - NO REPAIR REO'D. <br />START OF ARC <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL <br />(2)11 NAILS @ 8" O.C. <br />ARCH DETAIL J <br />4' MAX. RAD. <br />USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ <br />X O� Ry TO TRUSS TOP CHORD <br />qN <br />MIN. 4" EMBEDMENT AT 16" O.C. <br />+ lF <br />NOTN <br />11-0" 51-011 <br />SCALE: N.T.S. SS <br />12 <br />+ + PLYWOOD SHEATHING <br />JACK TRUSS PROVIDED BY SEE <br />+ + <br />TRUSS COMPANY OR PLAN <br />2x6 #2 SYP @ 24" O.C. <br />+ + <br />+ + <br />INISH FLO <br />2 <br />x 8 BUCK - CONNECT TO BLOCK SECTION <br />BLOCKING AS <br />+ <br />• <br />"� <br />WITH <br />1/4" x 31/4" TAPCON (1 1/4"MIN. B_B <br />ROOF SHEATHING ATTACHED � <br />+ REQUIRED <br />>.► .. • •: ► •.� <br />/4" MAX EMBEDMENT INTO ) <br />PER NAILING SCHEDULE ALL <br />TRUSS + TO SUPPORT <br />•.. • : ►; #5 BAR <br />BLOCK HEADER <br />2.0 g' <br />SOLID BLKG. AT TOP BTWN. ARCH <br />(5)12d NAILS SIMPSON <br />+ SOFFIT <br />+ <br />.• D <br />�' 10" • ► • * CENTERED W/ g <br />BLKG. & BUCK <br />2X6 TO 2X4 H2.5A w/ (10) <br />2X4 SYP ... <br />► • '► IN TOP C) <br />1 X 4 FURRING <br />8d NAILS <br />EACH TRUSS <br />► d .' KNOCKOUT / N <br />/ <br />• CHAIR BLOCK <br />� ! � <br />8d NAILS @ 8" O.C. AT BUCK <br />2 x 8 VERT. W! (2) 10d <br />°� <br />C � <br />O C O NNE T R <br />-_' I .• <br />PROVIDE 2 x 8 DIAG. BRACE BTWN*_,PROVIDE <br />NAILS AT EA. END <br />(2) MIN. <br />PROVIDE 2x � <br />CONT. W/ (3) <br />MONO FOOTING , <br />SIZE AND REINF. PER PLAN - ''. • ► . <br />VERT. BRACES WHEN HGT. OFTAPCON <br />AT EA. SIDE <br />12d NAILS ' <br />SEE LINTEL <br />AND SECTION DETAILS } <br />BRACE EXCEEDS 24" <br />BUCK - (1) WITHIN 4" <br />JACK TRUSS PROVIDED BY <br />SCHED. <br />LEAVE A CUT OUT IN O.S.B. ON T <br />MIN. OF START OF <br />TRUSS COMPANY OR 2x4 <br />CLEAN FILL J • • • <br />2 x 8 VERT. BRACES <br />() <br />INSIDE TO ALLOW FOR INSULATION <br />ARCH <br />#2 SYP @ 24" O.C. <br />bENTER SO IT <br />.► <br />DIRT Z <br />TO BE INSTALLED <br />00, <br />2 <br />BUILT UP PLWD. BUCK - <br />4'-1 MAX SEEP <br />PRECAST LINTEL <br />X.• <br />• STANDARD o <br />9 r HOOK N <br />SCRIBE (NOTCH) BACKSIDE <br />7/16" OSB ARCH PANEL <br />2X4 SYP #2 CONT. (MATCH TRUSS DEPTH <br />SEE ELEVATION <br />#5 BAR IN <br />TO FIT ARCH CONNECT W/ <br />NOTE: IF TRUSSES USED) W/ (2) #6 X 4'%" WOOD <br />FOR OVER HANG <br />FILLED CELL • ° - - , • ° , <br />8d NAILS <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />START OF ARC <br />SHED ROOF ENDS TO BE SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />(MAX. 4'-0") <br />BTWN. OSB ARCH FACES W/ (4)10d NAILS EQUAL EQUAL <br />4' MAX. RAD. <br />GABLE ONLY, CORNERS WALL USE (2)1/4" X 31/2" TAPCONS AT 16" <br />INSTALL WDW, SCREW ----'----' <br />CREW <br />THRU OSB INTO 2 x 8 <br />SHALL NOT BE FRAMED AS O.C. <br />ANCHOR INTO ARCH BLKG. <br />HIP. <br />STEMWALL FOOTING SIZE AND <br />PER INSTALLATION DETAILS <br />B-B <br />ARCH DETAIL �( <br />DESIGNED ONLY FOR THE SECTION @ ENTRY L <br />SECTION @ ROOF EXTENSION M <br />REINF. PERLAN AND STEMWALL <br />SCALE: N.T.S. SS <br />INSTALLATION OF SHINGLE SCALE: 3/4" = V-0" <br />SS <br />SCALE: 3/4" = 1'-1 <br />SS <br />MONO TO STEMWALL FOOTING SECTION DETAILS <br />AND METAL ROOF FINISH <br />SCALE: 3/4" = V-0" <br />GLASS BLOCK INSTALLATION NOTES <br />NOTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJECT, <br />A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />CONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />EXISTING ND BEAM. <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />MASONRY WALL. SEE PLAN FOR <br />D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />SEE SHEET D2 AND <br />EPDXY CAP TO PREVENT LEAKAGE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE EXPANSION STRIP <br />FLOOR PLAN FOR <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT 20 ga. PANEL <br />MORE INFO <br />TOP SPACE BETWEEN EXISTING GROUT &NEW GROUT <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS ANCHOR <br />SIMPSON HTT4 w/ (18)10d x 1 <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY t 2") <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />"SQUEEZED" <br />W .W.M. AT PERIMETER <br />1/2" NAILS TO STUDS & (1) - <br />COURSES TO PREVENT THE MORTAR FROM BEING OUT. 1/4" EXPANSION BOLT (2 <br />WHERE THIS CONDITION <br />(1) #5 BARS CONT. <br />5/8" DIA. ALL THREAD ROD <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />E PER ANCHOR INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS 9 a. PANEL ) <br />OCCURS <br />TOP WITH MIN. 3" <br />EPDXIED SIMPSON "SET" <br />zo <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING REINFORCING <br />COVER g _p <br />EPDXY MIN. 6" EMBEDMENT & <br />N. <br />¢ <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL (EVERY OTHER <br />3" MIN. EDGE DISTANCE <br />FILL CELL FULL HEIGHT W/ <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. COURSE) EXPANSION STRIP <br />U_ UJ NON SHRINK GROUT. <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />° <br />o v <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />, ;' ► <br />A <br />REINFORCING AS FOLLOWS: <br />0 a <br />SEALANT <br />' PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />g' ° <br />g <br />#5x6' EMBEDDED INTO <br />PRESS PANEL REINFORCING INTO PLACE. <br />6" MIN. LAP SPLICE W/ <br />► ° _ <br />Q g EXISTING FOOTING (2) #5x6' IN CONC. <br />' COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL REINFORCING PANEL <br />N FILLED CELL <br />SMOOTH. DO NO FURROW. <br />e , ° <br />DRILL MIN. HOLE <br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />� GRADE >. <br />R IN EPDXY <br />SET BAR N <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH, 6" MIN. LAP <br />p <br />g e <br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST SPLICE <br />CV ° <br />\ <br />REMAIN FREE OF MORTAR. NOTE: <br />M z <br />H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS SEE GLASS BLOCK INSTALLATION NOTES. <br />�, g • P <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE SEALANT <br />° " <br />-'0 <br />4" SAW CUT <br />GLASS BLOCK DETAIL <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY.TOOL <br />\ ' (2) #5 REBAR. MIN. 3" <br />OOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM NTS ^LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />16" MIN. COVER EA. WAY <br />SECTION <br />GLASS BLOCK <br />A <br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />L EXISTING FOOTING <br />IIIJJ <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />SCALE: N.T.S. <br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />SECTION AT DEEP MONO FOUNDATION <br />RETROFIT FOR MISSING MSTAM STRAP <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />RETROFIT FILLED CELL DETAIL <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />SCALE: 3/4" = 1'-0" <br />SCALE: 3/4" = 1'-0" <br />FOR WIND SPEEDS UP TO 110 MPH', PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />SCALE: N.T.S. <br />INSTALLATION OF GLASS BLOCK. <br />il. I(C.,1 4,tell, � <br />sr <br />0 V�J N <br />', �✓ N <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />U) <br />H <br />$ <br />o E <br />N <br />U <br />0 <br />Lo <br />N � # LL <br />C J <br />iK u"a <br />�,n2 J <br />NNo LL a - <br />M <br />mLLu: aw <br />0 <br />J <br />Z <br />_ o Mo <br />m c <br />� m N rn 'T <br />W <br />A�4'o aco <br />¢� <br />Z <br />IL <br />00 a <br />LO C14 Z 0� U) O <br />O U <br />Z <br />W <br />❑❑Q <br />z 5�� <br />z <br />a $ <br />2 <br />o <br />Q) <br />I <br />cf-.> <br />V1 <br />LL <br />_0*O <br />C- <br />t/1 <br />� <br />ti <br />M <br />JUA <br />w <br />Zo <br />EE o <br />V <br />� <br />�a <br />z�n° <br />°r <br />Q-� <br />z0. <br />o E <br />�~ <br />ai ~ <br />U) c� <br />9& <br />Z <br />J <br />ab <br />�_ <br />$ <br />0� <br />Zo <br />W <br />a� <br />U <br />A- <br />(D <br />w� <br />>g <br />C? <br />a <br />0 <br />>� <br />0 <br />m <br />0 <br />L <br />� <br />c <br />N <br />> <br />N <br />; <br />\\ <br />L.L V <br />N <br />m <br />C) <br />CO <br />T <br />Lo <br />(0 p <br />2 04 <br />r <br />T <br />3: N <br />00 N <br />r <br />w T <br />M <br />o <br />Z <br />E Q <br />y <br />m <br />a <br />E <br />U _j <br />?3 <br />Q p <br />c <br />c <br />JOB <br />NO: <br />21-1076 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SS <br />
The URL can be used to link to this page
Your browser does not support the video tag.