ELECTRICAL SPECIFICATION <br />15oazooAlNDOOR <br />PANEL CENTER <br />NOTES: <br />014 copper to lights & outlets <br />ELECTRICAL CONTRACTOR <br />NEMA 1 10 #12 copper to 20 amp cM <br />150 AMP/ <br />MUST VERIFY WITH THE <br />200 AMP #10.2 cropper to WH <br />SPECIFICATIONS FOR THE TYPE <br />#143 copper to Dryer <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />METER <br />T <br />LOCATION PURPOSES. <br />MAIN <br />2/0 or 4/0 SER Alu <br />0 r <br />200 amp <br />150 amp <br />UNDERGROUND isronnPOWER <br />CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 2%94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />Cb <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />F.0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />C)" <br />11111, <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />FtB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />10 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />®2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />VtKIfY Mt I tK <br />O THERMOSTAT LOCATION WITH <br />ELECTRIC METER BUILDER <br />owl ELECTRIC PANEL <br />DISCONNECT SWITCH <br />L J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />�NSo <br />N elk <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />v <br />qIN <br />ELECTRICAL PLAN — ELEV—B1 <br />SCALE:1/4"=1'-0" <br />N <br />0 <br />N <br />N <br />1 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building <br />Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />a <br />E <br />g mN8� <br />r <br />N p c <br />J tL <br />it -a d <br />Qaj <br />(n N 0 <br />ch <t <br />U- <br />,^ <br />J LL V- <br />SId <br />d u S <br />o <br />V <br />Z <br />o� <br />Lt M_ <br />N CO <br />0 ° <br />m 0 J <br />W <br />cR °' <br />Z <br />IL <br />04 Cl)rNi Z <br />V <br />y O <br />_j <br />Z <br />C1 <br />U rUn <br />. <br />0 R v <br />Z N <br />Z o <br />J. <br />N <br />N <br />M <br />O <br />LL <br />l <br />LLJ <br />0 <br />w g <br />,CA <br />Ly N <br />I <br />c� <br />LL N <br />r--• J E <br />� <br />I <br />8 <br />c.> <br />• <br />o <br />CID <br />M <br />J <br />o <br />ti a <br />Z <br />� <br />LJ_. <br />E I_ <br />E <br />W � <br />g O <br />Z <br />rp <br />z� <br />w0 <br />0U <br />Z <br />— <br />O E <br />NU <br />a o <br />o <br />a <br />ra <br />c <br />U <br />Zp <br />Z <br />VJ J <br />�b <br />s <br />Z <br />a� <br />o <br />W <br />LL_ <br />W <br />C <br />O <br />z <br />w <br />�O <br />C:) <br />CD <br />OW <br />'ate <br />3 <br />iu <br />J <br />Orn <br />M <br />m <br />L <br />J <br />F— <br />N <br />T <br />Lo <br />co O <br />2 N <br />T <br />oo N <br />T <br />T <br />CV <br />C) <br />O <br />Z <br />M <br />E Q <br />y <br />B <br />m <br />C <br />a <br />E <br />U _j <br />Q O <br />JOB <br />NO: <br />21-1076 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />