My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39849 Harvest Creek Ln
Zephyrhills
>
Building Department
>
Building Plans
>
39849 Harvest Creek Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 4:22:08 PM
Creation date
2/19/2025 2:42:07 PM
Metadata
Fields
Template:
Building Plans
Street #
39849
Location
Harvest Creek Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
2034
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed U180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided In composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with vertical (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load �� • O <br />Safe vertical Toad Safe horizontal load _ <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />101 E= <br />I <br />Wo. .2 <br />8F441B/1T8F401B/1T 8RF40OB/1T 8F321B/1T <br />FORM dr GROUT SOLID <br />�t :�4 <br />(V Q <br />o LU <br />�U <br />O #5 BAR CONT. <br />8F12-1 B/1 T <br />O <br />' V" LINTEL DETAIL <br />SCALE = N.T.S. <br />F = FILLED WITH <br />GROUT / <br />U = UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />F 16- <br />B/ 1 T <br />6 <br />�4 <br />tNOMINAL. <br />QUANTITYOF <br />WIDTH <br />#5 REBAR AT <br />TOP <br />NOMINAL - <br />HEIGHT <br />MATERIALS <br />-Tc precas intels = 3500 psi. <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />#SRER <br />MIN. <br />(1) 1)REQ'D <br />�� <br />ALTERNATE POWERS <br />STEEL LINTEL <br />° <br />= <br />a e • <br />° <br />.M.U. <br />#5 REBAR AT TOP <br />C7 <br />= <br />e • e <br />MIN. (1) REO'D a <br />1-1/2" CLEAR <br />• <br />° <br />• ° a <br />° <br />Z <br />GROUT <br />D <br />Z <br />• <br />4 <br />C.M.U. <br />e <br />5 REBAR AT <br />T <br />= to w <br />• <br />BOTTOM OF <br />r- re w - <br />w 4 <br />o-BOTTOM <br />LINTEL CAVITY <br />V , (~n \ <br />O <br />0 ci Z <br />REINFORCING <br />a ¢ C7 <br />LL <br />7-5/8"ACTUAL <br />e PROVIDED IN <br />Z O Lu N D I� D <br />3 <br />REBAR AT BOTTC <br />8" NOMINAL WIDTH <br />LINTEL <br />t_ Jo W pp Qo �, <br />.1 INDICATED <br />(VARIES) <br />rn o cr S ° A <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturers specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting <br />Refer to manufacturers specifications. <br />3. If lintel Is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementibuos coating. See contractor specifications <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION @ ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />O <br />4'-0" LL <br />O <br />6-10" LL <br />LINTEL PLAN - ELEV-131 <br />SCALE: Y4'=1'-0" <br />O <br />0 <br />0 <br />(V <br />N <br />0 <br />INKS <br />.� P'•••• • • <br />�1��. <br />•:� <br />pEi8750 <br />r <br />�'0 e `• F OR <br />•• .G�,�• <br />�O N PAS <br />��,.� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />5) <br />n <br />E � <br />�p �p ro <br />8 N <br />ci <br />0 <br />N oiC LL <br />4 ib °�, :k " <br />M <br />,F, a <br />�N0 u. a Y <br />U_ LL Wa w <br />0 <br />Z <br />tm�� <br />O0 J <br />C��� a 0 <br />7' <br />us <br />N MM Z h 0 <br />OU V�co <br />Z <br />Z <br />oo❑ <br />t-0 g <br />Z N <br />Z <br />Z r <br />J <br />d N <br />(nv) <br />- N <br />co <br />Z o <br />-1 <br />0 0 <br />4-1 <br />N LL <br />p <br />0- U <br />a <br />O <br />w g <br />� <br />�N <br />C y <br />in <br />(� <br />r- <br />U GF <br />tiJ J <br />" <br />U <br />Q <br />_ • <br />M <br />M <br />� <br />yi <br />w <br />Z <br />__J <br />o <br />zo <br />E <br />oo <br />>� <br />Zs <br />° <br />Q <br />O <br />E U <br />ao <br />w <br />Z <br />CQ E <br />f6 <br />o <br />$i <br />a <br />Z <br />aw <br />w <br />r0 <br />m� <br />F O <br />Z <br />>_ <br />i Z <br /><w <br />ZZ <br />°off <br />Z <br />-Z <br />W <br />TW <br />O <br />� <br />i°d <br />ax <br />�3 <br />0 <br />O 2 <br />= <br />O <br />c� <br />c <br />� <br />' <br />ca <br />J <br />r <br />Q <br />•- <br />,� <br />4) <br />N <br />o <br />U <br />C m <br />U <br />T <br />�p <br />Qi <br />T <br />(0 <br />= 04 <br />�- <br />_ <br />Q <br />r• <br />T <br />� <br />E <br />N <br />M <br />0 <br />Z <br />E o <br />L <br />M <br />a <br />U <br />Q Q <br />� <br />JOB <br />NO: <br />21-4277 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.