Laserfiche WebLink
SIMPSON HGAMV <br />W/ <br />(4)1/4"xl 1/2" SDS <br />SCREWS <br />TO BLOCKING & (i <br />1/4"x2 3/4" <br />TITEN TO CMU <br />SEE STRUCTURAL NOTES AND BACKNAIL W/ (2)16d NAILS BACKNAIL w/ (2) 16d NAILS SIMPSON H10A w/ (18) SIMPSON SP4 w/ 6 1 <br />TOENAIL W/ (2) 16d NAILS SIMPSON H10A w/ (18) () Od x <br />NAILING SCHEDULE FOR 10d x 1 12' AT EA. <br />2"x4" OUTLOOKER SEE STRUCTURAL NOTES AND 10d x 1 12" AT EA. 2"x4" SEE STRUCTURAL NOTES 1 12" AT EA STUD (USE BACKNAIL wl (2) 16d NAILS SIMPSON H10A w/ (18) <br />SHEATHING DETAIL OUTLOOKER OUTLOOKER SP6 FOR 2 6 WALL USE 10d 1 12" AT EA <br />@ 24" O.C.AND <br />7 <br />NAILING SCHEDULE FOR OUTLOOKER <br />NAILING SCHEDULE <br />@ 24" O.C. <br />TOP CHORD <br />SHEATHING DETAIL <br />OR SHEATHING <br />DETAIL <br />BLOCKING FOR <br />FIRST FOUR <br />ROWS OF <br />45° t <br />24" MAX. <br />TOP CORD BLOCKING 45°t <br />2X4 CONT"L" BRACE <br />TOP CORD BLOCKING <br />TRUSSES @ <br />SIMPSON H10A w/ (18) <br />FOR FIRST FOUR <br />FASTENED W/ (2) 10d 3" <br />FOR FIRST FOUR ROWS <br />EDGES OF 2x4 CRO BRACE <br />10d x 1 12" @ EA. <br />ROWS OF TRUSSES @ <br />AT 24" 0/C. CMID HEIGHT <br />OF TRUSSES @ EDGES <br />SHEATHING APPROX. 8" FROM <br />OUTLOOKER <br />EDGES OF <br />OF SHEATHING TYPICAL <br />TYPICAL @ RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />SHEATHING TYP. 2X4 KICKER <br />2x8 SYP#2 "L" BRACE TO <br />48" O.C. EACH JOINT W/ (3) 10d <br />AT LEAST 90% OF WEB <br />@ $'-0" 0/C. <br />EXTEND AT LEAST 90% OF <br />MAX. & (2)10d TOE NAILS @ <br />2x4 CROSS BRACE <br />WEB LENGTH & NOTCH AT <br />EA. END @ 48" O.C. <br />LENGTH (SEE TABLE) <br />APPROX. 8" FROM <br />BOTTOM CHORD (SEE TABLE) <br />2x6 P.T. <br />GABLE TRUSS <br />RIDGE FASTENED AT <br />SIMPSON H2.5A w/ (10) 8d <br />• <br />SILL <br />112" CDX PLYWOOD OR <br />EACH JOINT W/ (2) 10d <br />FROM LEDGER TO <br />J <br />7/16" OSB SHEATHING <br />& (2)10d TOE NAILS @ <br />BLOCKING <br />— <br />ATTACHED W/ 10d <br />EA. END <br />NAILS @ 6" O.C. EDGES <br />GYPSUM WALL BOARD <br />GABLE TRUSS <br />AND 12" O.C. FIELD <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />10dXT' 3" O/C <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />1/2" CDX PLYWOOD OR 7/16" <br />OSB SHEATHING ATTACHED <br />THROUGH CHORD <br />CORD ATTACHED W/ (2)16d TOENAILS <br />10d NAILS 6" O.C. <br />INTO 2"x6" P.T. PLATE <br />2"x4" LEDGER (MATCH BOTTOM CHORD <br />w/ @ <br />EDGES AND 12" O.C. FIELD <br />2x4 PANEL BLOCKING @ <br />2x4 "T" ON TOP OF PANEL BLOCKING, <br />WEEP SCREED <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />O.C. FOR THE FIRST (4) <br />FASTEN WITH 10dx3" @ 4" O/C SPACED <br />INSTALLED PER MANUF. <br />2"x6" P.T. SILL <br />NOTCH "L" BRACE HERE <br />ROWS OF TRUSSES FRO <br />@ 48" O.C. <br />5/8" x 10" "J" BOLT @ 48" O.C. <br />WEEP SCREED <br />EA. END TYP. TOP & <br />MOISTURE BARRIER <br />BOTTOM ATTACHED w/ <br />32" O.C.IMPSON <br />5/8"x 10" "J" BOLT @ O.C. MINIMUM 6" FROM <br />HETA20 w/ (8)10dx1 1/2" NAILS AT 6'-0" <br />INSTALLED PER MANUF. <br />16d TOENAILS <br />PLATE SPLICES W/ 332" PLATE WASHER <br />SIMPSON HETA20 w/ (8) <br />O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />MOISTURE BARRIER <br />10dx1 1/2" NAILS AT EA. <br />ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS <br />NOTE: IF EMBEDDED <br />TRUSS VERTICAL WEB (24" <br />& (4)1/4"X2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAPMISSEDSEMST SECTION <br />O.C. MAX) w/ MIN. 4" <br />EMBEDMENT IN KO BLOCK <br />GABLE WEB <br />SECTION <br />2 <br />M36W/AL <br />WEB, USE MSTAM36 w/ (7) <br />10d NAILS & (4) 1/4"x21/4" SCALE: N.T.S. <br />S`5 <br />SCALE: N.T.S. <br />S5 <br />TITEN ON OUTSIDE <br />SIMPSON H10A <br />w/ (18) <br />BACKNAIL W/ (2)16d NAILS <br />2) <br />SP8 FOR 2x8 WALL) <br />/ <br />SEE STRUCTURAL <br />NOTES. <br />OUTLOOKER <br />AND NAILING SCHEDULE <br />FOR SHEATHIN <br />DETAIL <br />2x4 OUTLOOKER <br />@ 24" O/C <br />2x4 OUTLOOKER @ 24" <br />TOP CORD <br />O.C. (OPTIONAL - SEE <br />4" MAX. <br />BLOCKING FOR <br />ELEVATIONS) <br />FIRST FOUR ROWS <br />DOUBLE TOP PLATE <br />OF TRUSSES @ <br />2x4 CROSS BRACE APPROX. 8" <br />2"x4"CROSS BRACE <br />24" MAX. EDGES OF <br />FROM RIDGE FASTENED AT <br />APPROX. 8" FROM <br />SHEATHING TYP. <br />EACH JOINT W/ (2)10d & (2)10d <br />RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />TOE NAILS @ EA. END <br />EACH JOINT W/ (2) <br />; <br />AT LEAST 90% OF WEB <br />10d & (2) 10d TOE <br />LENGTH (SEE TABLE) <br />2x FRAME WALL (SEE WALL <br />NAILS @ EA. END <br />GABLE TRUSS <br />SECTION FOR SIZE &SPACING) <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR <br />1/2' CDX PLYWOOD OR 7/16" <br />@ 48" O/C FOR THE <br />(2) 16d <br />7/16" OSB SHEATHING <br />OSB SHEATHING ATTACHED <br />FIRST (4) ROWS OF <br />NAILS <br />ATTACHED w/ 10d NAILS <br />W/ 10d NAILS @ 6" O.C. EDGES <br />AND 12" O.C. FIELD <br />TRUSSES FROM EA. <br />END TYP. TOP & <br />@ 6" O.C. EDGES AND 12" <br />O.C. FIELD <br />(2) 16d NAILS <br />BOTTOM ATTACHED <br />48" <br />2x BLOCKING <br />W/ (2)16d TOENAILS <br />2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />M <br />2x4 "T" ON TOP OF PANEL <br />SIMPSON <br />10dx3" @ 4" O/C <br />HGAIOKT w/ (4)1/4"x1 1/2" <br />BLOCKING, FASTEN WITH <br />SDS SCREWS <br />TO TRUSS & (4)1/4"x3" <br />10dx3" @ 4" 0/C <br />SDS SCREWS <br />TO PLATES AT 36" O.C. <br />SIMPSON SP2 w/ (12) 10d <br />2x4 LEDGER (MATCH BOTTOM <br />NAILS AT EACH STUD <br />CHORD SLOPE OF ADJACENT DBL. TOP PLATE <br />TRUSS) STUD WALL (SEE TYP. SEC.) <br />SECTION 3 SECTION 4 <br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 <br />REFER TO DETAIL J10d x 1 12" AT EA. 2x4 OUTLOOKER <br />ON SHEET S5 FOR f SEE STRUCTURAL---,,,,,,OUTLOOKER @ 24" O/C <br />X-BRACING, AND TOP co " NOTES AND NAILING TOP CORD <br />CHORD BLOCKING N SCHEDULE FOR BLOCKING FOR <br />INFORMATION <br />'° °° SHEATHING DETAIL OF TRUSST OSES @ ROWS <br />1 1 1/ 2"x4" CROSS BRACE 24" MAX. EDGES OF <br />WOOD TRUSSES APPROX. 8" FROM SHEATHING TYP. <br />RIDGE FASTENED AT "L" BRACE TO EXTEND <br />2X4 RAT RUN BRACING VEACH JOINT W/ 2 <br />AT 24" O.C. ON TOP OF 1 12" 1 1 2" 10d & 2 10d TOE) AT LEAST 90% OF WEB <br />() LENGTH (SEE TABLE) <br />BOTT. CHORD FOR 4 NAILS @ EA. END <br />TRUSS SPANS GABLE TRUSS <br />ATTACHED W/ 2 -16d 2x4 PANEL BLOCKING 1/2" CDX PLYWOOD OR 7/16" <br />AT EA. TRUSS JOINT @ 48" O/C FOR THE (2) 16d NAILS OSB SHEATHING ATTACHED <br />(2) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF FIRST (4) ROWS OF W/ 10d NAILS @ 6" O.C. <br />2x4 BLOCKING @ 24" OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS E ES AND 12" O.C. FIELD <br />TRUSSES FROM EA. <br />2x4 L CKIN (D = 0.148", L = 3") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL END TYP. TOP & t r<s ==r- JACK TRUSS <br />O/CTOENAILS @ EA. END NOTES: BOTTOM ATTACHEDSEE PLAN FOR <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL w/ (2)16d TOENAILS CONNECTION <br />MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) — <br />ARCHITECTURAL FINISH 2 ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL <br />2x4'T" ON TOP OF PANEL <br />OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) BLOCKING, FASTEN WITH 2X4 BLOCKING W/ 'r_! <br />10dx3" @ 4" O/C (2)12d TOENAILS <br />EXT. WALL CONN. a� 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION <br />NON -LOAD BEARING LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF <br />K" <br />D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) T <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: 3/4"=V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS $ SECTION g <br />2"x4" OUTLOOKER @ 24" - <br />O.C. W/ (2)10d PER JOINT <br />IINIMUM 2x _ <br />:ROSS BRACING <br />3EE PLAN FOR <br />OCATIONS) 10dx3" O/C <br />TOENAIL 6" O/C <br />W/ (2) 16d TYPICAL <br />(2) 16d PER NAILS <br />JOINT <br />�- CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 <br />CROSS BRACING DETAIL <br />12 <br />6.9 MAX. <br />SCALE: N.T.S. <br />2"x4"y <br />RUNNE <br />ALTERNATE NON -DROP <br />GABLE END DETAIL <br />SCALE: N.T.S. <br />1 GABLE TRUSS <br />ss <br />"L" BRACE W/ 10d @ 4" O.C. <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />S5 <br />GABLE END BRACING DETAIL <br />S5 <br />Jt— --- . <br />—`J <br />CONT. BEARING <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />PRE-ENGINEERED <br />WOOD TRUSSES <br />SCALE: N.T.S. S5 <br />S5 <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES 6" OVERLAP <br />`- MINIMUM (2)16d PER JOINT �- MINIMUM 2X4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL M <br />SCALE: N.T.S. S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />8d @ 6"O/C 2 x 4 BLOCKING w/ (2)10d <br />WOOD TRUSSES TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />0 <br />z <br />w <br />\-BRACINGw/(3) 10d x 3" AT <br />• EACH CONN. @ 24" O/C <br />SIMPSON HGAM10KTA w/ (4) MOISTURE BARRIER <br />1/4"xl 1/2" SDS SCREWS TO <br />BLOCKING & (4)1/4"x2 3/4" BOND BEAM <br />TITEN TO CMU <br />MASONRY WALL <br />2x4 BLOCKING 2x4 "T" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />10d NAILS @ 4" <br />O.C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 "T' BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ 10d NAILS @ 4" 0.C� <br />TYPICAL <br />GABLE TRUSS WEB <br />SINGLE "L" BRACING DETAIL 6 <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" O/C GABLE TRUSS <br />TRUSS VERTICAL <br />(2) 2"x8" "L" BRACE -� <br />FASTENED WITH (3) <br />16d PER SIDE <br />SCISSOR GABLE "T" BRACE 7 <br />AS PER HIB 91 SCALE: N.T.S. S5 <br />20'-0" MAX 20'-0" MAX <br />"X" BRACE SEE DET. J/S5 CONTINUOUS BOTTO CHORD BRACING 2X4 MIN. <br />��i�lll�ll <br />I�� <br />III <br />ARCHITECTURAL FINISH NOTE: <br />EXT. WALL CONN. NON -LOAD <br />BEARING LOCATION(UNEVEN CLG.) <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />"L" BRACING REQUIREMENTS <br />STUD <br />SPACING <br />NO <br />"L" BRACE <br />(1) 2"x4" (U.N.0.) <br />"L" BRACE <br />2"x6" (U.N.O.) <br />"L" BRACE <br />24" <br />0'0" - T-0" <br />T-0" - 6'-0" <br />6'-0" & GREATER <br />SCISSOR GABLE - (1) 2"W' #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGA10KT w/ (4) 1/4"x1 1/2"SDS ^ <br />UL...... <br />V <br />GABLE END BRACING DETAIL SCALE:3/4"=V-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SIMPSON SP2 w/ (12) <br />10d NAILS AT EACH <br />STUD <br />END JACK <br />1 V-0" MAX. <br />�q <br />o <br />CORNER JACK <br />C7 <br />Y <br />a <br />U <br />cc <br />w <br />z <br />0 <br />U <br />HIP FRAMING REFERENCE PLAN <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />THAT MY BE REQUIRED <br />2)7' BRACING MAY BE USED IN PLACE OF PERMANENT <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />AS PER BCSI 1-13 <br />SCISSOR TRUSS <br />SCISSOR TRUSS <br />W/ DROP CEILING BRACING DETAIL <br />LTOP & BOTTOM CHORD <br />GABLE END BRACING @ <br />4'-0" O.C. MAX. FOR <br />FIRST (4) ROWS OF TRUSSES <br />SCALE: N.T.S. <br />2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />FIXED LOCATION ATTACHED W/ (2)10d AT <br />EA. TRUSS (NOTE: BRACING MAY BE <br />PLACED ON EITHER TOP OR BOTTOM OF <br />THE BOTTOM CORD) <br />COSMETIC DROP CEILING FRAMING <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />lr-- - <br />Ir �r <br />I' II <br />I <br />z N <br />z <br />Q <br />Q <br />J f") <br />o <br />V1 <br />V LL <br />Cz''z^^ <br />+2 Y <br />c0 w cL <br />U <br />0 w <br />U0 c E <br />V1 <br />0 <br />U � <br />• <br />�0 <br />c <br />Q o <br />S� <br />Z o o z <br />Z� z <br />pC��.° a " <br />¢1Nlti�z <br />LULU go <br />= Q, <br />1fvWL <br />m�,I <br />z <br />3E <br />Lii� N •� . <br />Q brJ.O <br />_ z <br />.� iw <br />S, � 1"' F L�� <br />F <br />491 <br />\� <br />.� <br />�AirOr•,�ftNtll�1��• <br />. <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residenlial 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />C) <br />o <br />� <br />w <br />ch <br />o �Z <br />2 <br />0 <br />w� <br />sg <br />zo <br />39 <br />U <br />H ro <br />] <br />5U <br />�o <br />oa <br />U R <br />oo <br />z <br />o E <br />N <br />"= <br />g= <br />o <br />i <br />w= <br />1w <br />�w <br />l o <br />rn C <br />v <br />o. <br />°� <br />Z <br />Z <br />J <br />�p <br />ZO <br />W <br />U <br />�o <br />Mj <br />8a <br />o� <br />> Ln <br />L <br />/ > <br />00 <br />0 <br />r� <br />Uca <br />0 <br />° L)00 C <br />_ <br />0 <br />L,n <br />3.1 <br />cC0 <br />� <br />._ 00 o <br />a) <br />T <br />E <br />OLO <br />c'M N <br />o <br />z <br />O <br />E <br />m` <br />a <br />U -j a o <br />_ <br />°i <br />JOB <br />NO: 19-5895 <br />SCALE : AS NOTED <br />SHEET NO. <br />S5 <br />u z <br />