ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />014 copper to uohts a ouOetS <br />NEMA 1 # 1 2 copper to 20 amp ckts <br />200 AMP <br />#10-2 copper to wH <br />#10.3 copper to Dryer <br />METER <br />210 or 4/0 SER Alu <br />200 amp <br />150 amp <br />Disc nnLctPOWER <br />CO. FEEDINTERSYSTEM <br />e Cu Ground <br />BONDING <br />NDING WIRE <br />TERMINATION PER <br />� <br />WITH CODE APPROVED <br />NEC 14,250.94 <br />CLAMP PER 250,50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />�3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />OQ <br />RECESSED LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />{] <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />Sri_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />ND. COND. <br />DISCONNECT <br />WP <br />GFI <br />PATIO <br />WP <br />GFI <br />H.B. <br />-FAPAIL- -Ft00M \ <br />ROUGH -IN FOR � 12� -C <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRED <br />rwwwwwwwr ROUGH-INFOR <br />�� - �rrr• <br />LIGHT PRE -WIRE <br />12 <br />(� <br />/ <br />i 1Ir <br />FOYER <br />- <br />- <br />C.M <br />� <br />' <br />\ <br />rh <br />W.H. <br />I @ 44„ <br />A.F.F. <br />\ PENDANT AS <br />\PER SPECSOr----------In- <br />DININ OOM <br />2 CAR <br />GARAGE <br />Q <br />I <br />I I <br />&D <br />I <br />I I <br />I <br />I <br />I I <br />I I <br />GFI @ 44" <br />GFI FOR I <br />I I <br />A.F.F. <br />GAR. DOOR I <br />I I <br />�— <br />n GFI n <br />_ GFI <br />I I <br />11 I <br />L——————— — — — — —I <br />1101 <br />I <br />JL <br />I <br />kill <br />I <br />I <br />I I <br />I I <br />I <br />1 <br />- REF. <br />OPT. <br />- - <br />- <br />I IRRIGATION <br />VERIFY LOCATION L____________ <br />ELECTRICAL PANEL GFI @ 44" A.F.F. <br />qqj <br />GFI GFI <br />FI : <br />- <br />AIN <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />H.B. <br />1w, <br />ENTRY <br />I <br />I <br />r I <br />I <br />I <br />I <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />� R1i <br />S,X)" <br />_. <br />z � <br />z <br />d <br />a o <br />VMS <br />V(I)� <br />`�V <br />V LL <br />T C!J Y <br />W On <br />0 <br />c <br />� 8 <br />U 0 <br />• <br />pQ <br />N o <br />V�i N <br />w Z <br />U) Z^ <br />mr��ZO <br />--1 <br />W <br />Wa'. "Lo <br />o 0 <br />3 <br />Z_ O c a Q 3 <br />O <br />on <br />Z YQs, N <br />o <br />au,• <br />00 <br />U F <br />00 <br />rn <br />0 <br />N <br />00 <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages <br />bearing <br />Engineers signature and seal. <br />r— <br />o <br />ci <br />w <br />z <br />M <br />_ <br />O <br />wo <br />?® <br />Q <br />o <br />N UU0 <br />O ¢ <br />Op <br />? V <br />Z <br />ra <br />- 4? <br />ao <br />r Z <br />�o <br />c` <br />c <br />oZ <br />ZF <br />Z <br />VJ J <br />4b <br />�Z <br />W <br />rn 3 <br />� <br />U <br />8 <br />0 <br />o <br />o <br />V <br />� <br />it <br />0 3 <br />o r— <br />> Lo <br />L <br />0 <br />O <br />nC' m <br />v <br />0 <br />I� <br />W <br />O <br />3 <br />0) <br />Lnoo <br />N <br />= 00 <br />m <br />r- <br />ai <br />m <br />�• � <br />E 0 <br />ch N <br />o <br />Z <br />Z <br />E O <br />vi <br />f0 <br />a <br />E <br />0 _j <br />¢ o <br />JOB <br />NO: <br />19-5895 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.0 <br />