My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39907 Harvest Creek Ln
Zephyrhills
>
Building Department
>
Building Plans
>
39907 Harvest Creek Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 6:43:19 PM
Creation date
2/19/2025 2:44:51 PM
Metadata
Fields
Template:
Building Plans
Street #
39907
Location
Harvest Creek Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
2019
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3!4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1 1 /8" or two 1 /2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1 /2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) ° <br />k <br />Filler blocking ° <br />1/8" gap ° <br />x <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP @ TOP sides by 6". <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in <br />One 1 Od box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />10'-0" <br />at bearing. <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE 00 O <br />5'-0" Q - <br />STUB -OUT FOR 0 9 <br />LO <br />GAS METER O o <br />U <br />O � <br />N � <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />1IT-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />T-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />164" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block / <br />(2x4 minimum) _—/ <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />V/ Provide adequate bearing <br />for each lapped joist. <br />Od nails SECTION INT. BRG. WALL <br />N.T.S. <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) p <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />FILL CELL STD. 900 HOOK BOND BEAM <br />uJ <br />> STD.90° <br />CONT. #5 HOOK <br />BAR <br />CONT. #5 <br />BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />Y <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />@INT. BRG. WALL SECTION <br />N.T.S. <br />1/8" min. }Small gap 2" min. <br />2" max. 4" max. <br />Q <br />Clinch nails <br />when <br />possible 1 <br />Tight fit U <br />2x4/Plywood/OSB web stiffener <br />required when indicated or <br />- Hangers with side nailing. <br />- Hangers with sides not containing <br />top flange of joist. <br />- Birdsmouth cuts. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />— blocking and wall or beam below.* <br />Use 1 OdxY nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />• ■ • ■ ..EMMS <br />6"" A 1%" ROUND HOLE MAY J <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN %" <br />DO NOT CUT HOLES <br />LARGER THAN 1 z" <br />ROUND IN <br />CANTILEVERS. <br />16" jest 112 1 i'-0'° 1'_1.° 1' Z' 1-2" 1' 3" I'-g' 2-4° _11,. 3-7"° 1 4-2" 4-9' 5'-4' <br />---- - 1 s 1'-a- 1-4°° 1 2'° 4 �'° 1' i"• -5 ° 3'-2 ° S'-1 D'. 4 5= '• 4 ° 7-21 <br />-- 20 1,-,° 1�4' 1' 2' 1-2" 1 2-0a' I 34 4'-0" 4-10" S'-11" U-11" 7'-11°° 6-11- <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN, SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1 z" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1%" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. <br />2" min. <br />4" max. <br />WEB STIFFENER <br />N.T.S. <br />Web Stiffener Fastener Schedule <br />Joist Bearinq Location <br />Series De th End Intermediate <br />BCI 5000s® <br />9 1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BCI 6000s® <br />BCI6500s®, <br />9-1/2" <br />11-718" <br />2-8d <br />2-8d <br />_ 2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI 60sP <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />. <br />16" <br />2-8d <br />_ <br />6-8d <br />FBCI 90so <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/(22)' <br />NAILS I <br />5/8" 0 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) <br />NAILS I <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />AIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />1111L <br />Joist <br />I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S <br />Backer block (12" wide min.) <br />Nail with 10-1 Od nails. <br />-,.Install tight to top flange. <br />Joist hanger <br />y \ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />gap <br />I <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiff ner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />--T requirements <br />-0.6 X Joist <br />o depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEM—/ ° <br />SEE PLAN FOR °, ° . • <br />FOUNDATION INFO <br />STEM FOUNDATION <br />GRADE <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />REINF. SEE PLAN <br />(2) #5 REBAR <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />��® LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />IY7lME! \=M-rllnAI TLJr')1 1 CAM <br />TOP (2) #5's x 4'"0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE/F <br />PENETRATION PLUMBING LINE <br />q a d <br />d <br />�d • O. .• .,.. <br />/�— SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />a <br />d <br />,: <br />—TI=Tll-1 a 4 I— <br />o ° n <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />N <br />0 <br />N <br />CN <br />N <br />M <br />0 <br />.LE Wig <br />co No PE7S750 <br />••:* <br />• <br />• W Y. <br />.. <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />QO <br />cI E <br />OV N ik <br />ON N 6 J <br />O <br />O C: <br />M <br />cn�r�. w a <br />No LL a — <br />aaj <br />3 <br />WEMZC1to <br />c�tt Y <br />u6-'Ju- <br />o <br />U~ �w <br />CEO <br />i <br />O <br />of O <br />W <br />�2ODO <br />Z <br />LL <br />us <br />a <br />N MZ WLn 0 <br />U N <br />Z <br />O U <br />W <br />❑ ❑ ❑ <br />M <br />N O <br />— � o <br />z <br />z <br />J — <br />E3 <br />V1 <br />N <br />(h <br />z <br />0 <br />o <br />— <br />i--+ <br />t'a <br />w <br />N <br />W0*0 <br />U <br />,., <br />_ E <br />'illl li�iJi ll <br />U O N <br />O <br />C <br />Q N 0 <br />r_ <br />O <br />co <br />w <br />m <br />Cl)O <br />z <br />z <br />z <br />� <br />a O <br />E V <br />oo <br />z <br />zo <br />¢� <br />?© <br />oa <br />t— <br />XO <br />OQ <br />UU <br />�U <br />�< <br />O E <br />a p <br /><o <br />ri z <br />L <br />rp <br />() C <br />z <br />U <br />mC) <br />o <br />O LL <br />N 3 <br />o <br />Z <br />Qo <br />U <br />Q <br />d <br />U <br />a o <br />az <br />3 <br />o <br />>0 <br />O <br />V <br />a <br />zld <br />3 <br />c� <br />0 C <br />_ <br />0 <br />> Lo <br />m <br />m <br />0 <br />> <br />CU <br />J <br />T <br />�1 <br />T <br />N <br />0 <br />U <br />CD <br />U <br />W <br />T <br />c <br />r <br />NT <br />r <br />2 't <br />� N <br />r <br />r <br />co <br />m <br />c <br />O <br />Z <br />z <br />E <br />E <br />cc <br />a. <br />U <br />Q p <br />JOB <br />NO : <br />21-4273 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.