Laserfiche WebLink
a <br />N <br />O <br />Z <br />Z <br />Z <br />z <br />RA <br />O <br />z <br />O <br />z <br />O <br />O <br />z <br />wmce�Nce <br />�w�U°V)U <br />W <br />W <br />w <br />� <br />O <br />J > <br />0 <br />O <br />Co <br />2 <br />a: <br />O <br />W <br />_ <br />2 <br />J <br />> <br />D <br />O <br />m <br />2 <br />a <br />■ <br />■ <br />■ <br />■ <br />I <br />■ <br />GENERAL: <br />CS COVER SHEET <br />OWNER: <br />■ ■ F1 FIXTURE PLAN / LIFE SAFETY PLAN <br />MOOMEMOM <br />MOOMOMMO <br />00000000 <br />MOOMOMMO <br />0000110003 <br />lwwl__wllw <br />MOOMEMEM <br />MOOMMEME <br />IMOOMMEME <br />� <br />ARCHITECTURAL: <br />A00 ARCHITECTURAL SITE DETAILS <br />Al FLOOR PLAN <br />A2 EXTERIOR ELEVATIONS <br />A3 SECTIONS AND DETAILS <br />A3a SECTIONS AND DETAILS <br />A3b SECTIONS AND DETAILS <br />A4 ROOM FINISH SCHEDULE AND <br />SALES FLOOR ELEVATIONS <br />A5 DOOR SCHEDULE AND DETAILS <br />A6 ENLARGED PLANS AND TOILET ROOMS <br />A7 SIGN DETAILS <br />A8 SIGN BRACING DETAILS <br />A9 REFLECTED CEILING PLAN <br />A10 ROOF PLAN AND GUTTER DETAILS <br />All WALL TYPES <br />Al2 GENERAL NOTES <br />STRUCTURAL: <br />S1 STRUCTURAL GENERAL NOTES <br />S2 FOUNDATION PLAN AND SCHEDULES <br />S3 FOUNDATION SECTIONS AND DETAILS <br />S3A FOUNDATION SECTIONS AND DETAILS <br />S4 SECTIONS AND DETAILS <br />FIRE PROTECTION: <br />■ ■ FP1 FIRE PROTECTION SCHEDULES, NOTES, DETAILS <br />■ ■ FP2 FIRE PROTECTION ZONE PLAN <br />MECHANICAL: <br />■ ■ M1 HVAC LAYOUT <br />■ ■ M2 HVAC SCHEDULES / NOTES / DETAILS <br />PLUMBING: <br />MAI I I P1 PLUMBING PLANS AND SCHEDULE <br />■ ■ P2 PLUMBING DETAILS AND DIAGRAMS <br />■❑❑■0000 <br />■❑❑■■❑■M <br />■❑❑■■❑■■ <br />■❑❑M■❑■■ <br />■❑❑■■❑■■ <br />■❑❑■■■■■ <br />■❑❑■■❑■ <br />■❑❑■■❑■■ <br />---- <br />■❑❑■■❑■■ <br />■❑❑❑■❑❑■ <br />■❑❑❑■❑❑■ <br />■❑❑❑■❑❑■ <br />ELECTRICAL: <br />E1 POWER PLAN <br />E2 LIGHTING PLAN <br />E3 POWER POLE AND POWER TERMINAL DETAILS <br />E4 CABLE TRAY LAYOUT PLAN <br />E5 THREE PHASE ELECTRICAL PANELS <br />E6 FIRE ALARM PLAN <br />EMS1 EMS / LOW VOLTAGE PLAN <br />EMS2 CPU TERMINAL DIAGRAM <br />EMS3 CPU TERMINAL DIAGRAM <br />ES1 ELECTRICAL SITE LIGHTING AND POWER PLAN <br />ES2 SITE LIGHTING PHOTOMETRICS PLAN <br />ES3 SITE LIGHTING FIXTURE CUT SHEETS <br />-tiORK SHALL COMPLY WITH PREVAILING <br />..,Z;CS FLORIDABUILDING CODE, <br />":ATIONAL ELECTRIC CODE, <br />AND THE CITY OF ZEPHYRHILLS <br />ORDINANCES <br />\\ II \_\ III \\ III \ II <br />DOLLAR GENERAL STORE Store#23227 <br />4766 Gall Blvd, Zephyrhills, Florida 33542 <br />Based on 10,640 SF Prototype T " (Right Corner Entry, Right Rear Delivery) <br />Release date: 09/14/2020 <br />REQUIRED NATIONAL ACCOUNT VENDORS <br />COMPANY <br />CONTACTS <br />PHONE # <br />REQUIRED ITEMS <br />w <br />RAINBIRD IRRIGATION <br />LOCAL RAIN BIRD DISTRIBUTER <br />WWW.RAINBIRD.COM <br />IRRIGATION SYSTEMS <br />W <br />WO <br />EUCLID CHEMICAL <br />PHIL BRANDT <br />877-438-3826 <br />CONCRETE POLISHING SYSTEMS <br />z <br />COMPANY <br />PBrandt@euclidchemical.com <br />z <br />Cn <br />Z D <br />RETRO-PLATE SYSTEMS <br />SCOTT MAXFIELD <br />801-641-6796 <br />CONCRETE POLISHING SYSTEMS <br />0 <br />00 <br />scott.maxfield@retroplatesystem.com <br />RECORD DOOR SYSTEMS <br />MARK COLLADO <br />704-290-0237 <br />IN,KY,MD, MODEL #5100 SERIES <br />F- <br />dollargeneral@recorddoors.com <br />OH, PA,VA,WV <br />o w <br />STANLEY ACCESS <br />MATTHEW D. MATTHEWS <br />919-208-4238 <br />AR,AZ,CA,CO,CT,DE,IL,IA,KS,LA,MA,ME,MI,MN,MO, MODEL #DG2000 <br />w Q <br />TECHNOLOGIES <br />matt.matthews@sbdinc.com <br />ND,NE,NH,NJ,NM,NV,NY,OK,OR,RI,SD,TX,VT,WA,WI,WY <br />o z <br />ASSA ABLOY ENTRANCE <br />ROSS MERKLING <br />609-528-2580 <br />AL, FL, GA, MS, NC, SC, TN MODEL #SL500 <br />cn W <br />SYSTEMS <br />dollargeneral.besam.us@assaabloy.com <br />GIRTMAN AND ASSOCIATES <br />JUNE THOMPSON <br />615-964-6000 ext. 4527 <br />INTERIOR DOORS AND FRAMES AL,AR,AZ,CA,CO,FL,GA,IA,KS,LA,MS,MN,MO, <br />o U, <br />dgconstruction@bass-security.com <br />AND RESTROOM ACCESSORIES NE,NM,NV,OK,OR,SC,SD,TN,TX,WA,WI,WY <br />o10� <br />o <br />COOK & BOARDMAN GROUP <br />JOE HARRELL <br />336-837-0673 <br />INTERIOR DOORS AND FRAMES CT,DE,IL,IN,KY,MA,MD,ME,MI,NC,NH,NJ, <br />o <br />Z o <br />dgteam@cookandboardman.com <br />AND RESTROOM ACCESSORIES NY,OH,PA,RI,VA,VT,WV <br />co <br />SHERWIN WILLIAMS <br />LOCAL SHERWIN WILLIAMS STORE <br />PAINT, PRIMER, CONCRETE SEALER AND BLOCK FILLER <br />MC CUE CORPORATION <br />KEVIN O'NEILL <br />678-492-4026 koneill@mccue.com <br />TRIM KIT INCLUDES BUMPER GUARDS AND CART STOP <br />zLn <br />U <br />YORK <br />CHRIS ZINK <br />501-398-7008 <br />HVAC UNITS <br />york-dollargeneral-be@jci.com <br />AR,CO,IL,IN,KS,KY,MO,OH,OK,OR,TN,WA,WV <br />CARRIER <br />HASAN KHALIL <br />973-222-6742 <br />HVAC UNITS <br />BOB ECKWELLER <br />hasan.khalil@carrier.com <br />AL, AZ, CA, DE, FL, GA, LA, MD, MS, NC, NM, SC, TX,VA <br />bob.eckweiler@carrier.com <br />LENNOX <br />COLTON WHITESIDE <br />972-497-6652 <br />HVAC UNITS <br />Q <br />lennoxnationalaccounts@lennoxind.com <br />CT,IA,MA,ME,MI,MN,ND,NE,NH,NJ,NY,PA,RI,SD,VT,WI,WY <br />ROOF CURB SYSTEMS <br />CLIFTON REASOR <br />800-683-5848 <br />RTU CURB <br />DollarGeneral@roofcurb.com <br />CURBS PLUS INC. <br />ALLAN THRAILKILL <br />888-639-2872 <br />RTU CURB <br />alan.thrailkill@curbs-plus.com <br />Cn <br />co <br />of <br />KCC INTERNATIONAL INC. <br />GREG CONRAD <br />800-382-2872 <br />RTU CURB <br />Iwo <br />gconrad@kcccurbs.com <br />CED - CONSOLIDATED <br />ROBERT DECKER <br />270-781-2229 <br />ELECTRICAL SWITCH GEAR AR,AZ,CA,CO,IA,IN,IL,LA,KS,KY,MI,MN,MO, <br />it = <br />ELECTRICAL DISTRIBUTORS <br />robertd@cedbgky.com <br />MS,ND,NE,NM,NV,OK,OR,SD,TX,WA,WI,WY <br />I­_ <br />� Q <br />NESCO <br />CHRIS TRACY <br />800-244-6980 <br />ELECTRICAL SWITCH GEAR AL,CT,DE,FL,GA,MA,MD,ME,NC,NH,NJ, <br />w cn ( <br />dollargeneral@needhamelectric.com <br />NY,OH,PA,RI,SC,TN,VA,VT,WV <br />USLED <br />ROD LEEK (MAIN CONTACT) <br />352-789-4587 <br />ELECTRICAL LIGHTING AR,CO,IA,IL,IN,KS,KY,MI,MN,MO, <br />rleek@usled.com <br />SUPPLIES ND,NE,OH,OK,SD,WI,WV,WY <br />MITCH LAPENSON (SECONDARY <br />713-337-3840(D), 215-309-1975(M) <br />CONTACT) <br />mlapenson@usled.com <br />z <br />= <br />LEDS <br />MICHAEL STRINGER <br />920-915-4010 <br />ELECTRICAL LIGHTING AL,AZ,CA,CT,DE,FL,GA,LA,MA,MD,ME,MS,NC, <br />0 <br />J <br />KYLE KNAPP <br />DGORDERS@Ieds-Ilc.com <br />SUPPLIES NH,NJ,NM,NV,NY,OR,PA,RI,SC,TN,TX,VA,VT,WA <br />D&P CUSTOM LIGHTING <br />NATIONAL ACCOUNT SALES <br />800-251-2200 <br />CUSTOM POWER POLES <br />CROSSCOM NATIONAL <br />KEN MILLER <br />847-850-6298 <br />LOW VOLTAGE & VOICE/DATA CO,DE,FL,IA,IL,IN,KS,MD,ME,MI,MN,MO,ND, <br />C9w <br />dollargeneral@crosscomnational.com <br />NE,NH,NJ,NY,OH,SD,VT,WI,WV,WY <br />ASD <br />CHRIS RUDNITSKI <br />828-624-1046 <br />LOW VOLTAGE & VOICE/DATA AL,AR,AZ,CA,CT,GA,KY,LA,MA,MS,NC,NM,NV, <br />0 o crn <br />crudnitski@asd-usa.com <br />OK,OR,PA,RI,SC,TN,TX,VA,WA <br />GRAYBAR <br />JEROME BANNISTER <br />615-743-3202 office, 615-924-2135 cell <br />CABLE TRAY <br />DollarGeneral@graybar.com <br />EMERSON CLIMATE <br />TONY VERTUCA <br />404-824-9389 <br />EMS SUPPLIER NOTE: CUSTOMIZED DOLLAR GENERAL EMS PANEL REQUIRES <br />TECHNOLOGIES <br />NATIONAL ACCOUNT EXECUTIVE <br />STORE #, CITY, STATE, ZIP CODE & QTY. OF HVAC UNITS OF THE INSTALL SITE <br />WEBSITE: <br />USER NAME: dollargeneralbid <br />WHEN ORDERING. <br />Q <br />http://dollargeneralbid.emerson.com <br />PASSWORD: $Generall <br />STANLEY CONVERGENT <br />D'ETTA NERVES <br />858-752-7821 <br />INTERIOR FIRE ALARM PANELS <br />SECURITY SOLUTIONS <br />Detta.Neaves@sbdinc.com (pre -sale bid) <br />w <br />AI.Maier@sbdinc.com (post -award) <br />PROTOTYPE MANAGEMENT TEAM <br />COMPANY <br />CONTACTS <br />PHONE # <br />MJM ARCHITECTS <br />GARY CONWAY <br />615-244-8170 <br />www.mjmarch.com <br />dg@mjmarch.com <br />ENTECH <br />MITCH SIMPSON <br />615-373-2640 <br />www.entechtn.com <br />email@entechtn.com <br />NATIONAL <br />ACCOUNT <br />& CONTACT <br />INFORMATION <br />SUBJECT <br />TO CHANGE <br />REQUIRED SUBMITTALS <br />REQUIRED SUBMITTALS FOR THIS PROJECT INCLUDE: <br />STOREFRONT DRAWINGS <br />ELECTRICAL SWITCH GEAR <br />AUTOMATIC ENTRY DOORS <br />LIGHTING <br />CONCRETE MIX DESIGN <br />METAL CANOPY <br />HVAC UNITS <br />SPANDREL GLAZING <br />PLUMBING FIXTURES <br />PRODUCT APPROVAL INFORMATION SHEET <br />PROJECT NAME: DOLLAR GENERAL - ZEPHYRHILLS, FL (CITY OF ZEPHYRHILLS) <br />PROJECTADDRESS: 4766 GALL BLVD. ZEPHYRHILLS, FL 33542 <br />AS REQUIRED BY FLORIDA STATUTE 553,842 AND FLORIDA ADMINISTRATIVE CODE 96-72, PLEASE PROVIDE THE INFORMATION AND PRODUCT APPROVAL NUMBER(S) <br />FOR THE BUILDING COMPONENTS LISTED BELOW AS APPLICABLE TO THE BUILDING CONSTRUCTION PROJECT FOR THE PERMIT NUMBER LISTED ABOVE. YOU <br />SHOULD CONTACT YOUR PRODUCT SUPPLIER IF YOU DO NOT KNOW THE PRODUCT APPROVAL NUMBER FOR ANY OF THE APPLICABLE LISTED PRODUCTS. <br />INFORMATION REGARDING STATEWIDE PRODUCT APPROVAL MAY BE OBTAINED AT: www.floridabuilding.org. <br />CATEGORY: MANUFACTURER: PRODUCT LIMITATION DESIGN PRODUCT <br />DESCRIPTION: OF USE: PRESSURE: APPROVAL: <br />A. EXTERIOR DOORS <br />SWINGING <br />CURRIES DOORS <br />MODEL 747 SINGLE FLUSH DOOR OR PAIR OF <br />APPROVED FOR USE IN <br />+62/-62 psf <br />FL 8394.5-R6 <br />FLUSH DOORS <br />HVHZ - IMPACT RESISTANT <br />SWINGING <br />CURRIES DOORS <br />MODEL 707 SINGLE FLUSH DOOR <br />APPROVED FOR USE IN <br />+85/-85 psf <br />FL 8394.1-R6 <br />HVHZ - IMPACT RESISTANT <br />B. EXTERIOR DOORS <br />AUTOMATIC <br />ASSAABLOY ENTRANCE <br />SL 500 RESILIENCE R104 FULL BREAKOUT BI-PART <br />NOT HVHZ APPROVED <br />+80/-80 psf <br />FL 30356.3-R4 <br />SYSTEMS US INC. <br />LARGE AND SMALL MISSILE IMPACT DOOR SYSTEM <br />C. CLADDING <br />WALL PANEL <br />NICHIHA, USA <br />NICHIHA ARCHITECTURAL WALL PANELS UP TO 7/8" <br />APPROVED FOR USE IN <br />+95/-95 psf <br />FL 12875.1-R8 <br />THICKNESS <br />HVHZ <br />D.STOREFRONT <br />STOREFRONT <br />TKAWNEER <br />SERIES IR500-LMI ALUMINUM STOREFRONT SYSTEM <br />APPROVED FOR USE IN <br />+/- N/A psf��787.1-Rll <br />HVHZ - IMPACT RESISTANT <br />E. PREFABRICATED METAL BUILDING <br />METAL SIDING <br />NUCOR BUILDING <br />CLASSIC STEEL WALL PANEL <br />APPROVED FOR USE <br />+45/45 psf <br />FL 2686.2-R6 <br />SYSTEMS <br />OUTSIDE HVHZ <br />METAL SIDING <br />NUCOR BUILDING <br />REVERSE CLASSIC STEEL WALL PANEL <br />APPROVED FOR USE <br />+45/45 psf <br />FL 2686.3-R6 <br />SYSTEMS <br />OUTSIDE HVHZ <br />ROOF DECK <br />NUCOR BUILDING <br />STEEL CFR PANEL <br />APPROVED FOR USE <br />+N/A / -108.8 psf <br />FL 4891.1-R9 <br />SYSTEMS <br />OUTSIDE HVHZ <br />IN ADDITION TO COMPLETING THE ABOVE LIST OF MANUFACTURERS, PRODUCT DESCRIPTION AND STATE APPROVAL NUMBER OF THE PRODUCTS USED ON <br />THIS PROJECT, IT IS THE CONTRACTOR'S OR AUTHORIZED AGENT'S RESPONSIBILITY TO HAVE A LEGIBLE COPY OF EACH MANUFACTURER'S PRINTED <br />INSTRUCTIONS, ALONG WITH THE LISTABOVE, ON THE JOB SITE AVAILABLE TO THE INSPECTOR. <br />STRUCTURE IS NOT LIGHT FRAME <br />TRUSS CONSTRUCTION <br />COMPONENTS AND CLADDING <br />EXPOSURE"C" <br />DESIGN WINDLOAD PRESSURE: 137 MPH (ULT). <br />ROOF �6'' <br />O +17 psf <br />-42 psf h=21'-4' 3 2 3 <br />O+17 psf 55 <br />-70 psf 2 1� 2 <br />+17 psf O 3 2 3 <br />105 psf <br />5 <br />WALLS O 5 4 5 <br />+42 psf O O <br />O -45 psf <br />a=7'-7" TYP <br />+42 psf <br />-56 psf 140-8" <br />GENERAL NOTES: <br />BUILDING MUST COMPLY WITH ALL BUILDING (FEDERAL, STATE AND LOCAL), FIRE, ADA <br />AND HEALTH DEPARTMENT CODES. <br />NO TAPERED COLUMNS ALLOWED. <br />MAINTAIN INTERIOR CLEAR SPACE AS REQUIRED ON PLANS. <br />METAL BUILDING COLUMNS SHALL BE STRAIGHT. COLUMNS AND INTERIOR COLUMNS MAY <br />REQUIRE WRITTEN APPROVAL. MAINTAIN INTERIOR CLEARANCE BETWEEN FACE OF <br />COLUMNS AND SALES FLOOR AS NOTED ON PLANS <br />LIGHT FRAME TRUSS NOTE: <br />THIS PROJECT DOES NOT USE LIGHT FRAME TRUSS CONSTRUCTION <br />SEAL: JOHN BENEDICT POLSINELLI, AR96059 <br />THIS DRAWING SHALL NOTE BE USED FOR <br />CONSTRUCTION PURPOSES UNTIL THE SEAL AND <br />SIGNATURE OF THE RESPONSIBLE REGISTRANT <br />APPEARS ON THE DRAWING, AND PROPER PERMIT <br />FORMS AND RELATED FEES ARE TRANSMITTED BY <br />THE OWNER, OWNER'S AGENT OR CONTRACTOR <br />TO THE AUTHORITY HAVING JURISDICTION. <br />DATE <br />ISSUED FOR <br />REV <br />03/29/2021 <br />PEMB COORDINATION <br />05/20/2021 <br />CIVIL SUBMISSION <br />05/20/2021 <br />DUKE COORDINATION <br />06/07/2021 <br />PEMB COORDINATION 02 <br />08/09/2021 <br />CIVIL RESUBMISSION 1 <br />08/25/2021 <br />OWNER REVIEW <br />1 1 /08/2021 <br />REVISED ELEVATIONS <br />1 1 /29/2021 <br />PERMIT SUBMITTAL <br />Project Manager <br />Drawn <br />L. LONG <br />S. KORTMAN <br />Project Leader <br />Checked <br />L. LONG <br />Date <br />Dept Mgr Approval <br />02/23/2021 <br />Client <br />PALMETTO ZEPHYRHILLS - GALL BLVD., LLC <br />P.O. Box 1615, <br />Thomasville, GA 31799 <br />Office: (229) 226-1 1 77 <br />Contact: Daniel Tubb <br />Project <br />DOLLAR GENERAL <br />Corner of Gall Boulevard and C <br />Avenue, <br />Zephyrhills, FL 33542 <br />(City of Zephyrhills) <br />Store #: 23227 t <br />Drawing Title n <br />COVER SHEET 1 <br />DO NOT SCALE DRAWING <br />Project No. <br />Drawing No. <br />JCDT.20.0451 <br />CS <br />� U <br />