My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
4766 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
4766 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 6:53:22 PM
Creation date
2/19/2025 2:45:15 PM
Metadata
Fields
Template:
Building Plans
Street #
4766
Location
Gall Blvd
Contractor
Miller Construction Management
Building Plans - Permit #
3320
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TOUCH <br />THERMOSTAT <br />CABLES/ WIRING SPECIFICATIONS <br />FROM Supervisor WITHIN <br />RS485 MODBUS NETWORK <br />POWER WIRING (24VAC) ^ ECHELON NETWORK <br />( ) ( ) <br />i <br />i=i i==i <br />14AWG - BELDEN 9495 EuroTech (APAC) P/N: ET3801-107 <br />oC <br />v <br />16AWG - BELDEN 9494 Flow PCN: 108-5005 <br />v v <br />18AWG - BELDEN 9493 <br />o A 1 <br />MAXIMUM WIRE LENGTH PER SEGMENT: 200 METERS <br />o 0 0 <br />M o 0 <br />MAXIMUM ALLOWABLE WIRE LENGTH FOR EACH GAUGE: MAXIMUM OF 20 NODES PER SEGMENT <br />o <br />c + <br />For 14AWG: Lmax = 1200 / VA (in feet) <br />z <br />v <br />For 16AWG: Lmax = 750 / VA (in feet) <br />00/1AIT DAAICI <br />For 18AWG: Lmax = 462 / VA (in feet) 5 ETHERNET CROSS -OVER CABLE <br />`1 <br />JUMPER WIRE BETWEEN R & Rc MUST BE <br />FIELD INSTALLED. � <br />❑ <br />0 <br />GND <br />24VAC COMMON - BLACK <br />0 <br />B+ <br />24VAC POWER - RED <br />0 <br />A- <br />HEAT STAGE 1 -WHITE <br />❑ <br />0 <br />— <br />tAUX <br />HEAT STAGE 2 - BROWN <br />❑0� <br />O❑❑ <br />0 <br />IN1 <br />0 <br />❑❑ <br />WHT <br />0 <br />0 <br />IN2 <br />IN3 Y1 <br />❑ <br />COOL STAGE 1 -YELLOW <br />& <br />❑ <br />0 <br />IN4 Y2 <br />COOL STAGE 2 - BLUE <br />0 <br />❑ <br />BLK <br />❑01N5 <br />0 <br />7&❑ <br />GND ECO <br />❑ <br />0 <br />— G <br />- FAN - GREEN <br />CHASSIS <br />GROUND <br />REAR PANEL <br />T m (TERMINALS) <br />� x <br />a <br />i o 0 <br />c <br />w <br />x <br />WHT BLK <br />BLK BLK <br />v <br />TO NEXT TOUCH THERMOSTAT <br />WITHIN RS485 MODBUS NETWORK SUPPLY AIR TEMP <br />(201-0041) <br />THERMOSTAT WIRING DETAIL <br />Thi <br />Pmduit JMOD J HOOK <br />Caddy CABLECAT <br />j� <br />0 <br />9 <br />�� •._. � I V III; <br />CAT124234 CAT32PLR --it! <br />CAT214234 JMJH2-X20 JMDWB-I-X <br />NOTES: <br />1) ALL CABLING SHOULD BE HANDLED AND INSTALLED PER MANUFACTURERS SPECIFICATIONS AND IN <br />COMPLIANCE WITH ALL GOVERNMENT CODES <br />2) THE USE OF THE ABOVE ILLUSTRATED (OR EQUIVALENT) DROP CEILING WIRE HANGARS IS REQUIRED <br />WITHIN THE CEILING VOIDS TO MEET OR EXCEED GOVERNMENT CODES. (BEAM, PURLIN, AND WALL <br />MOUNTING IS ALSO ACCEPTABLE AS OUTLINED WITHIN THESE GUIDELINES) <br />3) ALL CABLING SHOULD BE PROPERLY SECURED TO PREVENT CONTACT AND CLOSE PROXIMITY TO HIGH <br />VOLTAGE WIREWAYS AND COMPONENTS (E.G. LIGHTING BALLASTS) <br />4) CABLING SERVICE LOOPS SHOULD BE PROVIDED AT EACH END OF THE CABLE RUN WITHIN THE CEILING <br />VOID AND SAFELY TIED TO THE CLOSEST HANGAR <br />5) ONCE CABLING RUNS ARE INSTALLED SECURE THEM WITH THE CORRECT CABLE TIES AS PER <br />MANUFACTURER'S SPECIFICATIONS, MEETING OR EXCEEDING GOVERNMENT CODES <br />1. CABLE MANAGEMENT - CEILING VOID <br />' TYPICAL MASONRY <br />TYPICAL DRYWALL li <br />+. FASTENERS FASTENER h �K�' � -�)��` - <br />i <br />1)ZIP-IT7v-' '� a <br />2)--°(:1�Y�-- 3)(�F { <br />2) MOLLY <br />3) TOGGLES , J <br />€a <br />NOTES: <br />1) USE ZIP -IT, MOLLY, OR TOGGLE BOLTS FOR DRYWALL ANCHORING AND SIZE ACCORDING TO APPLICATION. <br />FASTENERS SHOULD COMPLY WITH OR EXCEED GOVERNMENT CODES. <br />2) NO LESS THAN A #10 SCREW SIZED FASTENER SHOULD BE USED IN MOUNTING THE E2, ALARM OR LIGHTING <br />BYPASS PANEL. <br />3) THE LIGHTING AND BASE PANELS SHOULD BE STUD MOUNTED WITH NO LESS THAN A #6X2" SCREW. IN <br />CASES WHERE STUDS ARE EITHER NOT AVAILABLE OR CONVENIENT, A COMBINATION OF STUD AND MINIMUM <br />#6 MOLLY/TOGGLE FASTENERS SHOULD BE USED. <br />4)' ANOTHER OPTION IS SPANNING AN OVERSIZED 1/2" PLYWOOD SHEET ACROSS THE STUDS FASTENING THE <br />PANELS TO THE SHEET WITH NO LESS THAN A #6x1" SCREW. <br />5) IF THE WALLS ARE UNFINISHED MASONRY, #B OR GREATER MASONRY FASTENERS ARE TO BE USED <br />2. WALL ANCHORS <br />19 <br />TERMINATE LAST <br />UNIT BY <br />SWITCHING <br />DIPSWITCH 2 ON <br />NOTE: <br />24VAC COMMON MUST BE INSTALLED <br />FOR SINGLE TRANSFORMER SYSTEM <br />JUMPER SHOULD BE INSTALLED BETWEEN R & RC <br />FOR DUAL TRANSFORMER SYSTEM <br />NO JUMPER REQUIRED BETWEEN R & RC <br />—THERMOSTAT POWER IS PROVIDED ON TERMINALS C & R <br />FAILURE TO REMOVE JUMPER ON DUAL TRANSFORMER <br />INSTALLATION COULD CAUSE SEVER DAMAGE TO HVAC SYSTEMS <br />NOTES: <br />1) CONDUIT SHOULD BE RUN FOR ALL INDOOR APPLICATIONS UP TO 8'AFF AS ILLUSTRATED BELOW AND <br />SUPPORTED PER GOVERNMENT CODES <br />2) CABLE RUNS WITHIN OPEN CEILING AREAS ABOVE 8'AFF CAN BE FREE WIRED AT 90° VECTORS PARALLEL <br />WITH FLOORS, CEILINGS, AND WALLS AND SAFELY SECURED WITH SCREWED IN TIE BASES AS ILLUSTRATED <br />BELOW. THERE SHOULD BE NO SAG BETWEEN BASES AND CABLE TENSIONS SHOULD NOT EXCEED <br />MANUFACTURER'S SPECIFICATIONS. <br />3) SPECIAL CARE SHOULD BE TAKEN TO PREVENT CABLE CONTACT WITH HIGH VOLTAGE WIRING AND <br />MAGNETIC LOADS. IF UNABLE TO AVOID HIGH VOLTAGE WIRE WAYS, CABLING CAN CROSS THE WIRE WAYS AS <br />LONG AS THE CABLES RUN PERPENDICULAR AND NOT EXPOSED TO POTENTIAL DAMAGE. <br />TYPICAL EMT STANDPIPE ";` WALL STUDS, <br />WITH ADAPTER AND �_ WHERE PRESENT, <br />INSULATED BUSHING '�'' ARE PREFERRED <br />FOR ANCHORING. <br />USE A TOGGLE <br />TYPE ANCHOR IN <br />M ALL OTHER <br />j. <br />If � APPLICATIONS <br />I <br />r <br />EMT WALL STRAP <br />f .:7 <br />TYPICAL CABLE TIED CABLES WITH SCREW <br />MOUNT BASE <br />3. CABLE MANAGEMENT - WORKSPACE <br />ACCEPTABLE CLASS 1 HIGH VOLTAGE ACCEPTABLE CLASS 1 & 2` <br />WIRE NUTS <br />OUTDOOR INDOOR '-SS 224VAC ONLY <br />GEL FILLED USE ACCEPTABLE CLASS 1 & 2 CONNECTION <br />TAPE <br />x 4 =t <br />1) ALL CLASS 1 HIGH VOLTAGE CONNECTIONS WITHOUT OEM PROVIDED LUG TERMINALS SHOULD BE MADE USING <br />THE ABOVE ILLUSTRATED CORRECTLY SIZED CONNECTORS. <br />2) ALL CLASS 1 HIGH VOLTAGE AND CLASS 2 (24VAC ONLY) SPLICES SHOULD BE DONE WITH THE USE OF THE ABOVE <br />ILLUSTRATED AND PROPERLY SIZED WIRE NUTS (GEL FILLED FOR OUTDOOR OR HUMID ENVIRONMENT USE) EACH <br />SPLICE SHOULD BE TAPED CLOCKWISE AROUND THE WIRE NUT AND ENTERING WIRES SO AS TO PROMOTE A SOUND <br />AND SAFE CONNECTION. <br />3) ALL CLASS 2 LOW VOLTAGE SPLICES SHOULD BE MADE WITH THE ABOVE ILLUSTRATED GEL SEAL CONNECTORS. <br />ALL CONNECTIONS SHOULD BE TAPED COVERING THE CONNECTOR AND CONDUCTOR ENTRANCE. <br />4) THESE PROCEDURES ARE DESIGNED TO MEET OR EXCEED GOVERNMENT CODES AND OEM STANDARDS. <br />4. CABLE MANAGEMENT - CONNECTORS <br />2 RS485 1/0 NETWORK - (REVERSE POLARITY) <br />9600 BAUD <br />BELDEN 8761 (22AWG, 600V) CPC P/N: 135-0600 <br />MAXIMUM DAISY CHAIN CABLE DISTANCE: <br />4000 FT OR 1219 METERS (FOR 22 AWG) <br />RS485 CABLE FOR CPC AND DIXELL TEMP. SENSORS <br />2 a "IF LONGER THAN THE PROBE LENGTH SUPPLIED. <br />BELDEN 8761 (22AWG, 600V) CPC P/N: 135-0600 <br />RS485 MODBUS NETWORK - (REVERSE POLARITY) <br />3 <br />9600 BAUD - FOR ECT MODBUS <br />19200 BAUD - FOR ECT MODBUS <br />BELDEN 8761 (22AWG, 600V) CPC PIN: 135-0600 <br />MAXIMUM DAISY CHAIN CABLE DISTANCE.- <br />4000 FT OR 1219 METERS (FOR 22 AWG) <br />MAXIMUM OF 25 DEVICES PER LEG / SEGMENT. <br />RS485 MODBUS NETWORK - (SAME POLARITY) <br />3a <br />9600 BAUD - FOR DIXELL MODBUS <br />19200 BAUD - FOR DIXELL MODBUS <br />BELDEN 8761 (22AWG, 600V) CPC P/N: 135-0600 <br />MAXIMUM DAISY CHAIN CABLE DISTANCE: <br />4000 FT OR 1219 METERS (FOR 22 AWG) <br />9600 BAUD - MAXIMUM OF 32 DEVICES PER LEG / SEGMENT. <br />19200 BAUD - MAXIMUM OF 25 DEVICES PER LEG /SEGMENT. <br />RS485 CABLE / BELDEN 8761 EQUIVALENT: <br />SHIELDED TWISTED PAIR <br />18-22AWG <br />CAPACITANCE BETWEEN SIGNAL WIRES <br />31pF/ft OR LESS <br />(9.45 m) OR LESS <br />CAPACITANCE BETWEEN SIGNAL AND SHIELD <br />59pF/ft OR LESS <br />(17.98 m) OR LESS <br />NOMINAL IMPEDANCE: 120 OHMS +/- 50 OHMS <br />CABLE SHIELD SHOULD BE FOLLOW MANUFACTURER'S SPECIFICATIONS FOR <br />PROTECTED BY EITHER THE PVC SPLICING CABLES: <br />JACKET OR ELECTRICAL TAPE TO 1) CONDUCTORS SHOULD NOT BE STRIPPED FOR <br />PREVENT SHORTS SCOTCKLOK UR2 CONNECTORS (FULL INSTRUCTIONS ON <br />BOX). <br />--( TRIM I--- 2) USE OF A SCOTCHLOK CRIMPING TOOL IS REQUIRED (SEE <br />FIGURE C3.3) MAKE SURE CONDUCTORS ARE PUSHED ALL <br />THE WAY INTO THE CONNECTOR <br />i <br />1 <br />OUTSIDE OF THE 1/0 NETWORK (SEE NOTE 2 BELOW) THE DRAIN <br />WIRE IS TO BE: <br />1) TRIMMED FLUSH TO THE PVC JACKET AT THE END FURTHEST <br />FROM THE BASE PANEL <br />2) TERMINATED TO GROUND INSIDE THE BASE PANEL FOR SIGNAL <br />GROUND <br />NOTES: <br />1) ALL INCOMING CLASS 2 DC CABLES SHOULD BE RUN AWAY FROM HIGH VOLTAGE WIREWAYS, <br />2) THE I/O NETWORK (RS485) USES THE DRAIN WIRE AS A CONDUCTOR CONNECTED TO THE 'OV" TERMINAL OF EACH <br />DEVICE IN THE NETWORK. <br />3) SPECIAL CARE SHOULD BE TAKEN WHEN STRIPPING CABLE JACKETS SO AS NOT TO NICK OR DAMAGE <br />CONDUCTOR INSULATION (PREVENTING OPPORTUNITIES FOR SHORTS). <br />4) A MINIMUM OF 12" OF PVC JACKETING SHOULD BE REMOVED FROM THE CABLE END TO ALLOW FOR TERMINATION <br />OF ALL CONDUCTORS (NOT ALL TERMINALS ARE IN CLOSE PROXIMITY). <br />5) PVC JACKET SHOULD BE STRETCHED OVER ANY REMAINING FOIL (OR TAPED WITH ELECTRICAL TAPE) SO AS TO <br />PREVENT SHORTING. <br />1. CABLE MANAGEMENT - 3M CONNECTORS <br />CABLE SHIELD SHOULD BE DC4141 CRIMPING INSTRUCTIONS <br />PROTECTED BY EITHER THE PVC 1) INSERT DOLPHIN SUPER B-WIRE CONNECTOR FROM THE <br />JACKET OR ELECTRICAL TAPE TO FRONT OF THE TOOL, NOT FROM THE SIDE. FOLLOW THE <br />PREVENT SHO TR S 1 RED STRIPE WITH THE B-CONNECTOR HORIZONTAL DOWN <br />THE MIDDLE OF THE RED LINE. MAKE SURE THE <br />B-CONNECTOR IS EVEN ON BOTH SIDES OF THE RED LINE <br />'i BEFORE CRIMPING. <br />o 14� 2) STRIP 2 TO WIRES, SOLID OR STRANDED, 24 TO 22 <br />GAUGE WIRES, TO A %" OF INSULATION AND TWIST WIRES <br />TOGETHER BEFORE INSERTION INTO B-CONNECTOR. <br />3) RATCHET CRIMPING TOOL UNTIL TOOL SPRINGS OPEN. <br />OUTSIDE OF THE 1/0 NETWORK (RS485) THE DRAIN WIRE IS <br />TO BE; <br />1) TRIMMED FLUSH TO THE PVC JACKET AT THE END <br />FURTHEST FROM THE BASE PANEL <br />2) TERMINATED TO GROUND INSIDE THE BASE PANEL FOR <br />SIGNAL GROUND <br />NOTES: <br />1) ALL INCOMING CLASS 2 DC CABLES SHOULD BE RUN AWAY FROM HIGH VOLTAGE WIREWAYS. <br />2) SPECIAL CARE SHOULD BE TAKEN WHEN STRIPPING CABLE JACKETS SO AS NOT TO NICK OR DAMAGE <br />CONDUCTOR INSULATION (PREVENTING OPPORTUNITIES FOR SHORTS). <br />3) A MINIMUM OF 12" OF PVC JACKETING SHOULD BE REMOVED FROM THE CABLE END TO ALLOW FOR TERMINATION <br />OF ALL CONDUCTORS (NOT ALL TERMINALS ARE IN CLOSE PROXIMITY). <br />4) CABLE FOIL SHOULD BE NEATLY TRIMMED TO THE PVC JACKET AND THE DRAIN WIRE RUN TO THE LOCALLY <br />PROVIDED GROUND TERMINAL FOR SIGNAL GROUND. (RS485 WIRING IS THE EXCEPTION TO THIS RULE SINCE THE <br />DRAIN WIRE IS GROUNDED AT THE BOARD) <br />5) PVC JACKET SHOULD BE STRETCHED OVER ANY REMAINING FOIL (OR TAPED) SO AS TO PREVENT SHORTING. <br />2. CABLE MANAGEMENT - DOLPHIN CONNECTORS <br />6 ETHERNET STRAIGHT CABLE <br />4 PAIR ScTP, CAT5E, 24AWG SOLID BARE COPPER, <br />WITH FOIL SHIELD BONDED TO JACKET AND <br />24AWG DRAIN WIRE. <br />TDS8PC5 PLUGS. <br />BELDEN BEL-1533R-XX (PVC) 200MHz <br />BELDEN BEL-1533P-YY (PLENUM) 350MHz <br />MAXIMUM CABLE LENGTH: 328 FT OR 100 METERS <br />7 BELDEN 8771 <br />SHIELDED 3-CONDUCTOR CABLE, 22 GA WIRE. <br />FOR PRESSURE TRANSDUCERS AND HUMIDITY SENSORS. <br />8 BELDEN 8729 <br />SHIELDED 4-CONDUCTOR CABLE, 22 GA WIRE. <br />FOR LIGHT LEVEL SENSORS, AND DEWPOINT SENSORS <br />BELDEN 9418 <br />9 <br />4-CONDUCTOR CABLE, 18AWG WIRE. <br />FOR ESR VALVES (MAXIMUM OF 150 FT). <br />CABLE / WIRING SPECIFICATIONS <br />t & <br />MODEL•- <br />i3 -A <br />DOLPHIN DC-4141 <br />3M MODEL E-9Y OR <br />KLEIN MODEL D234-6C <br />3. CABLE MANAGEMENT - SPLICING TOOLS <br />ACCEPTABLE CLASS 2 LOW VOLTAGE BUTT CONNECTORS <br />PART # PART # <br />110-9907 110-1000 <br />E %, <br />ACCEPTABLE CLASS 1 & 2 <br />ELECTRICAL TAPE SCOTCHCODE WRITE <br />ON LABELS <br />4. CABLE MANAGEMENT - CONNECTORS AND LABELS <br />CONSULTANT: <br />SEAL: SEAN PATRICK PIC-KELL, PE 83946 <br />/ <br />\ gICK p"'//, <br />No. 83946 <br />STATE OF :k/�\ <br />/ IIIIIIII\11\\\ <br />"2 l �2,( <br />THIS DRAWING SHALL NOT BE USED FOR <br />CONSTRUCTION PURPOSES UNTIL THE SEAL AND <br />SIGNATURE OF THE RESPONSIBLE REGISTRANT <br />APPEARS ON THE DRAWING, AND PROPER PERMIT <br />FORMS AND RELATED FEES ARE TRANSMITTED BY <br />THE OWNER, OWNER'S AGENT OR CONTRACTOR <br />TO THE AUTHORITY HAVING JURISDICTION. <br />DATE <br />ISSUED FOR <br />REV <br />03/29/2021 <br />PEMB COORDINATION <br />05/20/2021 <br />CIVIL SUBMISSION <br />05/20/2021 <br />DUKE COORDINATION <br />06/07/2021 <br />PEMB COORDINATION 02 <br />08/09/2021 <br />CIVIL RESUBMISSION 1 <br />08/25/2021 <br />OWNER REVIEW <br />1 1 /08/2021 <br />REVISED ELEVATIONS <br />1 1 /29/2021 <br />PERMIT SUBMITTAL <br />Project Manager <br />Drawn <br />L. LONG <br />N. NGUYEN <br />Project Leader <br />Checked <br />L. LONG <br />M. GOOD <br />Date <br />Dept Mgr Approval <br />02/23/2021 <br />M. GOOD <br />Client <br />PALMETTO ZEPHYRHILLS - GALL BLVD., LLC <br />P.O. Box 1615, <br />Thomasville, GA 31 799 <br />Office: (229) 226-1 177 <br />Contact: Daniel Tubb <br />Project <br />DOLLAR GENERAL <br />Corner of Gall Boulevard and C <br />Avenue, <br />Zephyrhills, FL 33542 <br />(City of Zephyrhills) <br />Store #: 23227 <br />Drawing Title <br />CPU TREMINAL DIAGRAM <br />DO NOT SCALE DRAWING <br />Project No. <br />Drawing No. <br />.JCDT.20.04S 1 <br />EMS3 <br />