Laserfiche WebLink
SIMPSON HGAM1( <br />W/ <br />(4)1/4"x1 1/2" SDS <br />SCREWS <br />TO BLOCKING & (� <br />1 /4"x2 3/4" <br />TITEN TO CMU <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END, <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING AND <br />FASTENERS, (MIN. FIRST 4 BAYS) <br />SEE STRUCTURAL NOTES AND NAILING TOENAIL w/ <br />SCHEDULE FOR SHEATHING DETAIL-7 (2) 16d NAILS <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />MAX, 9" AND FASTENERS. (MIN, FIRST 4 BAYS) <br />UNSUPPORTED, <br />IF >9" SEE 1 O/S5 BACKNAIL w/ (2)16d NAILS —� <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />MAX 9" SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />UNSUPPORTED, AND FASTENERS. (MIN. FIRST 4 BAYS) <br />IF >9" SEE 10/S5 <br />BACKNAIL w/ (2) 16d NAILS <br />SEE STRUCTURAL NOTES AND NAILING <br />SCHEDULE FOR SHEATHING DETAIL \ <br />45°± <br />/ <br />45• ± <br />SEE STRUCTURAL <br />NOTES AND NAILING <br />2x4 CRO BRACE <br />SCHEDULE FOR <br />APPROX. 8" FROM <br />SHEATHING DETAIL 2x4 KICKER <br />2x8 SYP "L" BRACE TO <br />RIDGE FASTENED AT <br />@ 8-0' 0/C. <br />EXTEND AT LEAST 90% OF <br />, <br />EACH JOINT W/ (3) 10d <br />"L" BRACE TO EXTEND <br />2x4 CROSS BRACE <br />WEB LENGTH & NOTCH AT <br />' <br />& (2)1 Od TOE NAILS @ <br />AT LEAST 90% OF WEB <br />APPROX. 8" FROM <br />BOTTOM CHORD (SEE TABLE) <br />EA. END @ 48" O.C. <br />LENGTH (SEE TABLE) <br />RIDGE FASTENED AT <br />SIMPSON H2.5A w/ (10) 8d <br />2x8 P.T. <br />GABLE TRUSS <br />EACH JOINT w/ (3} 10d & <br />FROM LEDGER TO <br />SILL <br />1/2" CDX PLYWOOD OR <br />E2N1DOd TOE NAILS @ EA. <br />BLOCKING <br />' <br />7/16" OSB SHEATHING <br />GYPSUM WALL BOARD <br />ATTACHED W/ 10d <br />GABLE TRUSS <br />NAILS @ 6" O.C. EDGES <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />1/2" CDX PLYWOOD OR 7/16" <br />' <br />AND 12" O.C. FIELD <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />7OSB <br />SHEATHING ATTACHED <br />10dX3" @ 3" 0/C <br />CORD ATTACHED W/ (2)16d TOENAILS <br />w/ 10d NAILS @ 6 O.C. <br />THROUGH CHORD <br />2"x4" LEDGER (MATCH BOTTOM CHORD <br />EDGES AND 12" O.C. FIELD <br />INTO 2"x6" P T PLATE <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />AND FASTENERS. (MIN. FIRST 4 BAYS) <br />MAX. 9" <br />UNSUPPORTED, BACKNAIL w/ (2)16d NAILS <br />IF >9" SEE 10/S5 SEE STRUCTURAL NOTES AND <br />fa NAILING SCHEDULE FOR SHEATHING <br />`— DOUBLE TOP PLATE <br />2"x4" CROSS BRACE <br />2x4 CROSS BRACE APPROX. 8" <br />APPROX. 8" FROM <br />FROM RIDGE FASTENED AT <br />RIDGE FASTENED AT <br />EACH JOINT w/ (3)1 Od & (2)1 Od <br />EACH JOINT w/ (3) <br />TOE NAILS @ EA. END <br />10d & (2)10d TOE <br />NAILS @ EA. END <br />2x FRAME WALL (SEE WALL <br />SECTION FOR SIZE & SPACING) <br />2x4 PANEL BLOCKING <br />PLYWOOD OR 7/16" <br />@ 48" O/C FOR THE <br />,,,-1/2"CDX <br />OSB SHEATHING ATTACHED <br />FIRST ROWS OF <br />W/ 10d NAILS @ 6" O.C. EDGES <br />TRUSSES FROM EA. <br />AND 12" O.C. FIELD <br />END TYP. TOP & <br />BOTTOM ATTACHED <br />(2)16d NAILS <br />W/ (2)16d TOENAILS <br />2x4 "T" ON TOP OF PANEL BLOCKING, 2"x6" P.T. SILL NOTCH "L"BRACE HERE 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING <br />WEEP SCREED THE FIRST (4) ROWS OF TRUSSES <br />FASTEN WITH 10dx3" @ 4" 0/C SPACED 1/2" x 8" "J" BOLT @ 48" 0 C 2x4 "T" ON TOP OF PANEL <br />4 <br />(2)16d <br />NAILS' <br />@ 48" O.G. INSTALLED PER MANUF. WEEP SCREED FROM EA. END TYP. TOP &BOTTOM BLOCKING, FASTEN WITH SIMPSON HGAIOKT w/ (4) 1/4"x1 1/2" SDS SCREWS TO --- <br />MOISTURE BARRIER SIMPSON META12 w/ (7)1Odx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2)16d TOENAILS 10dx3" @ 4" 0/C TRUSS & (4)1/4"x3" SDS SCREWS TO PLATES AT 24" O.C. <br />1/2 x 8 J BOLT @ 32 O.C. MINIMUM 6 FROM O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER MOISTURE BARRIER <br />SIMPSON META12 w/ (7) ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS <br />NOTE: IF EMBEDDED 1Odx1 1/2" NAILS AT EA. & (4) 1/4"x2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL SECTION TRUSS VERTICAL WEB (24" GABLE WEB SECTION <br />WEB, USE MSTAM36 w/ (7) O.C. MAX) w/ MIN. 4" 2 <br />1Od NAILS & (4)1/4"x2 1/4" SCALE: N.T.S. EMBEDMENT IN KO BLOCK <br />TITEN ON OUTSIDE S5 SCALE: N.T.S. S5 <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />REFER TO DETAIL J <br />N <br />N <br />AND FASTENERS. (MIN. FIRST 4 BAYS) <br />ON SHEET S5 FOR <br />X-BRACING, AND TOP <br />r <br />M <br />' <br />SEE STRUCTURAL <br />CHORD BLOCKING <br />N <br />NOTES AND NAILING <br />INFORMATION <br />SCHEDULE FOR <br />SHEATHING DETAIL <br />BACKNAIL w/ <br />WOOD TRUSSES <br />ao <br />1 1 <br />I, <br />00 <br />2"x4" CROSS BRACE <br />(2)16d NAILS <br />APPROX. 8" FROM <br />2x4 RAT RUN BRACING <br />RIDGE FASTENED AT <br />AT 24" O.C. ON TOP OF <br />EACH JOINT w/ (3) <br />BOTT. CHORD FOR 4 <br />10d & (2)10d TOE <br />TRUSS SPANS <br />ATTACHED W/ 2 -16d <br />LLL•������ <br />(�j <br />NAILS @ EA, END <br />AT EA. TRUSS JOINT <br />„ <br />2 W/ 1 W <br />2 x 4 LAMINATIONS ROW <br />() �) <br />3 2 x4 LAMINATIONS W/ 1 ROW <br />() () <br />I / ROWS F <br />3 2 x 6 LAMINATIONS W 2 OW 0 <br />() () <br />2x4 PANEL BLOCKING <br />OF STAGGERED 10d COMMON WIRE NAILS <br />OF STAGGERED 30d COMMON WIRE NAILS <br />STAGGERED 30d COMMON WIRE NAILS <br />@48 O/C FOR THE <br />2 <br />O16d NAILS <br />2x4 BLOCKING 24" <br />@ <br />(D = 0.148", L = 3") OR EQUAL <br />(D = 0.207", L = 41/2") OR EQUAL <br />(D = 0.207", L = 41/2") OR EQUAL <br />FIRST (4) ROWS OF <br />O/C w/ (2)16d <br />TRUSSES FROM EA. <br />TOENAILS @ EA. END <br />NOTES: <br />END TYP. TOP & <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA, x 51/2" LAG SCREWS OR EQUAL <br />BOTTOM ATTACHED <br />MASONRY WALL <br />OF THE COLUMN <br />(SPACE AS SHOWN FOR 3-PLY) <br />w/ (2)16d TOENAILS <br />ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL <br />OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) <br />EXT. WALL CONK. �a 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2) 16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION <br />NON - LOAD BEARING LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF <br />[� B.U.C., SAME NUMBER OF ROWS, SAME SPACING) <br />SEE TYP. WALL SECTION FOR SCALE:3/4"=1'-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNSr8 <br />ADDITIONAL INFORMATION. <br />1INIMUM 2x <br />'ROSS BRACING <br />SEE PLAN FOR <br />OCATIONS) TOENAIL ti <br />(2)16d NA <br />(2)16d PER <br />JOINT <br />,.,... ,.. ,... , .., ...... ,.,..� �.., 2"x4" MIN. SEE M/S5 <br />CROSS BRACING DETAIL <br />SCALE: N.T.S. <br />12" <br />ISH SCHEDULE <br />kTTACHMENT <br />? SYP BLK'G @ 16" O.C. <br />i x 0.131" <br />AILS EA. SIDE <br />2x4.#2 SYP w/ 1 Od <br />XO.131" @ 8" O.C. <br />ALTERNATE NON -DROP <br />GABLE END DETAIL ri 0 <br />SCALE: N.T.S. S5 <br />CONT. BEARING <br />GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. <br />SCALE: N.T.S. <br />PRE-ENGINEERED <br />WOOD TRUSSES <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR <br />7/16" OSB SHEATHING <br />ATTACHED w/ 10d NAILS <br />@ 6" O.C. EDGES AND 12" <br />O.C. FIELD <br />"2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />1Odx3" @ 4" O/C <br />2x4 LEDGER MATCH BOTTOM CHORD DBL. TOP PLATE SIMPSON SP2 w/ (12)10d <br />( NAILS AT EACH STUD <br />SLOPE OF ADJACENT TRUSS) STUD WALL (SEE TYP, SEC.) <br />SECTION 3 SECTION 4 <br />SCALE: N.T.S. SCJ SCALE: N.T.S. CJ'S <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR 7/16" <br />OSB SHEATHING ATTACHED <br />W/ 1Od NAILS @ 6" O.C. <br />E ES AND 12" O.C. FIELD <br />JACK TRUSS <br />SEE PLAN FOR <br />CONNECTION <br />2x4 "T" ON TOP OF PANEL--/ <br />L <br />BLOCKING, FASTEN WITH <br />2X4 BLOCKING W/ <br />1 Odx3" @ 4" O/C <br />(2)12d TOENAILS <br />[E <br />SECTION <br />g <br />SCALE: N.T.S, <br />�CJ <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES <br />\-- MINIMUM (2)16d PER JOINT \-- MINIMUM 2X4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL <br />SCALE: N.T.S <br />6" OVERLAP <br />M <br />S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />8d @ 6"0/C <br />WOOD TRUSSES <br />SIMPSON HGAM10KTA w/ (4) <br />1/4"xl 1/2" SDS SCREWS TO <br />BLOCKING & (4)1/4"X2 3/4" <br />TITEN TO CMU <br />2 x 4 BLOCKING w/ (2) 10d <br />TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />Q <br />z <br />-1 aW <br />BRACING w/ (3) 1 Od x 3" AT = <br />• EACH CONN. @ 24" O/C <br />MOISTURE BARRIER <br />BOND BEAM <br />MASONRY WALL <br />ARCHITECTURAL FINISH <br />EXT. WALL CONN. @ NON - LOAD <br />BEARING LOCATION (UNEVEN CLG.) <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />"L" BRACING REQUIREMENTS <br />STUD <br />SPACING <br />NO <br />"L" BRACE <br />(1) 2"x4" (U.N.O.) <br />"L" BRACE <br />2"x6" (U,N.O.) <br />"L" BRACE <br />24" <br />O'0" - T-O" <br />3'-0" - 6'-0" <br />6'-0" & GREATER <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGA10KT w/ (4) 1/4"x1 1/2" SDS <br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS <br />TO PLATES (TYP.) <br />\—STUDS @ 16" O.C. <br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />TRUSS <br />SIMPSON SP2 w/ (12) <br />10d NAILS AT EACH <br />STUD <br />END JACK <br />1 V-0" MAX. <br />o <br />� <br />z <br />CORNERJACK <br />x <br />w <br />z <br />O <br />HIP FRAMING REFERENCE PLAN <br />20'-0" MAX <br />"X" BRACE SEE DET, J/S5 , <br />2x4 BLOCKING 2x4 "T" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />10d NAILS @ 4" <br />O.C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 "T" BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ 1 Od NAILS @ 4' O.0 <br />TYPICAL <br />GABLE TRUSS WEB <br />SINGLE "L" BRACING DETAIL 6 <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" O/C GABLE TRUSS <br />TRUSS VERTICAL <br />(2) 2"x8" "L" BRACE -i <br />FASTENED WITH (3) <br />16d PER SIDE <br />SCISSOR GABLE "T" BRACE <br />AS PER HIB 91 SCALE: N.T.S. S5 <br />-0" MAX 20' <br />CONTINUOUS BOTTOI CHORD BRACING 2X4 MIN. <br />'01 <br />i <br />151111111111111111 <br />NOTE: ZTOP CHORD 2X4 #2 SYP BRACING <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />ZBOTTOM <br />@ 16" O.C. MAX. FOR FIRST (4) <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />BAYS <br />THAT MY BE REQUIRED <br />CHORD GABLE END BRACING <br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT <br />@ 4'-0" O.C. MAX. FOR FIRST (4) BAYS <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />/ 1 <br />AS PER BCSI <br />SCISSOR TRUSS <br />SCISSOR TRUSS <br />W/ DROP CEILING BRACING DETAIL <br />SCALE: N.T.S. <br />2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />FIXED LOCATION ATTACHED W/ (2)1 Od AT <br />EA. TRUSS (NOTE: BRACING MAY BE <br />PLACED ON EITHER TOP OR BOTTOM OF <br />THE BOTTOM CORD) <br />COSMETIC DROP CEILING FRAMING <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T,S. <br />FOR WIND SPEED SPECIFICATION <br />s� <br />o <br />a� -o <br />> w , <br />.3-9 <br />N -N to <br />�>: �-tea <br />= <br />6, <br />q• <br />v <br />= 2 <br />11 <br />t <br />L c1% <br />r <br />s P4 E <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />c Wa M, W <br />;, <br />8 <br />Q <br />N <br />( . 0 ib <br />�° N �No�zSz5z <br />e J LL 5Lt a... <br />a <br />' Z r �o o� z <br />Nzo <br />co <br />ILZ '- <br />N <br />O C) O <br />W ❑❑ <br />Z N o <br />o <br />z <br />z o <br />Q <br />r <br />Vi a <br />0 <br />0 <br />(L) .o <br />O^ <br />l N <br />V) � ) <br />'OftL <br />U <br />1�..r LU J <br />ol'`•-. <br />U o N <br />C U) s <br />Q N C1 <br />z <br />M <br />y <br />°¢ <br />z <br />Q <br />_1 <br />U- <br />C6 E <br />Q <br />E U <br />. <br />w o <br />F2 <br />3° <br />F z <br />2 <br />> <br />Q� <br />ze <br />o a <br />O E <br />E <br />z <br />00 <br />o< <br />d z <br />N <br />4 <br />.2 <br />Q <br />C <br />o <br />o <br />U <br />y0 <br />0 <br />o� <br />z <br />}z <br />—�^ <br />< °a <br />In <br />[� <br />~O g <br />Z <br />zo <br />J U <br />-z <br />w<. <br />2� <br />o <br />w� <br />10¢ <br />>° <br />aF <br />OV <br />Ct' <br />O <br />C <br />a) <br />> M <br />r�r/ <br />LL <br />0 <br />m <br />N <br />Co <br />V <br />W <br />L <br />T <br />� r <br />r <br />Q <br />Y <br />N <br />a <br />U) 0' <br />LO <br />[0 <br />O <br />o <br />C'4 <br />O <br />� <br />N <br />Q `V <br />r <br />t` <br />ai <br />m <br />N <br />00 ij <br />o <br />z <br />E r <br />CU <br />c <br />@ <br />CL <br />E o m <br />o <br />C) J Q Q <br />J <br />JOB <br />NO: 22-06454 <br />SCALE : AS NOTED <br />SHEET N0. <br />S5 <br />