Laserfiche WebLink
3 <br />I <br />n <br />N <br />s <br />M <br />7t <br />N <br />0 <br />Cn <br />0 <br />.o <br />Q <br />R <br />0 <br />ra <br />0 <br />I <br />N <br />0 <br />_ <br />i) <br />0 <br />a <br />Q <br />E <br />0 <br />v <br />i <br />N <br />LZ <br />-) <br />VI <br />.o <br />d <br />o <br />O <br />0 <br />J <br />cD <br />L <br />an <br />0 <br />0 <br />0- <br />Lo <br />4 <br />m <br />0 <br />CROSS BRACING DETAIL (TYP.) <br />SCALE: N.T.S. <br />TRUSS NOTES: <br />CONV. FRAMED RIDGE <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2, ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. CB <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. DB <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP TRUSS BLOCKING DETAILS <br />YY/ L-Iuu `W "P' I I I\VVV YY 4"I-, <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLOCKING NAILED @ <br />- EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 10d x <br />1 1/2" NAILS EACH <br />W. <br />PRE-ENG. TRUSS <br />2X4 BLOCKING <br />2X4 DIAGONAL AT 8'-0" O.C. BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP - <br />MAX & EACH END ALTERNATE CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. —� 1 <br />DIAGONAL - <br />AT 8'-0" <br />MAX <br />2X4 CONT. AT <br />T & B CHORD <br />�3 <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />10d TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 (2) #7X 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />* 2x8 #2 SPF RIDGE BEAM <br />2x6 RAFTERS FOR SPANS 4FT TO 8FT <br />2X4 RAFTERS FOR SPANS LESS THAN <br />4FT @ 2'-0"0.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO BEAM <br />CONC. MASONRY <br />STEEL OR WOOD <br />BEARING SUPPORT <br />SEE ROOF <br />PLAN SHEATHING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER JACK <br />USSES HIP <br />SIDE OR BOTH IF REQ'D) G.T <br />(2) 12D NAILS AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />SCALE: N.T.S. <br />WOOD POST. SEE FLR__T <br />PLAN FOR SIZE & BASE <br />CONNECTION SEE <br />PLAN <br />EXTEND <br />SLAB 1 1/2" <br />--1 -- • (2) #5's CONT. T&B w/ <br />#3 STIRRUPS AT 4'-0" <br />PORCH SLAB SEE - WHEN DEPTH <br />7 <br />FOUNDATION PLAN - EXCEEDS 30" <br />/�- I �1� RADE <br />1 <br />111 -4 <br />ENTRY PORCH SILL 14 <br />SCALE: N.T.S. <br />WOOD OR MASONRY ABOVE <br />MASONRY PIER SEE FLOOR PLAN Lj <br />FOR COLUMN INFO WOOD OR MASONRY <br />ABOVE MASONRY <br />z <br />0 <br />Q <br />W <br />J <br />w <br />w <br />w <br />U) <br />INTEGRATE M <br />KNEEWALL IN <br />MAIN HOUSE <br />REQUIRED <br />' <br />MASONRY KN <br />COURSES w/ <br />w/(1)#5CONT <br />SEE CUT WHEN DEPTH - • ' - <br />CONTRACTOR TO INSTALL #3 STIRRUPS AT 4'-0" <br />MIN 3" x 3" WEEP HOLE SECTION FOR --- <br />ALONG w/ PITCHING SLAB MORE INFO EXCEEDS 30"' <br />1'-4" <br />TO DRAIN WATER <br />KNEEWALL OPT. (ELEV TO INDICATE) MASONRY COLUMN <br />ENTRY PORCH SILL 16 <br />SCALE: N.T.S. <br />TOP COURSE TO <br />BE CHAIR BLOCKS. <br />ENTIRE BASE TO <br />BE FILLED SOLID <br />SEE ELEV. FOR <br />BLK HGT. <br />#5 REBAR CONT <br />@ SLAB LEVEL <br />EXTEND SLAB <br />1 1/2" BEYOND <br />BLOCK FACE <br />EXTEND <br />SLAB 1 1/2" <br />A -A ALTERNATE BLOCKING <br />SIMPSON LSTA18L. <br />Od NAILS <br />CENTERED AT <br />SIMPSONHUC410w/(14) <br />16d INTO HEADER & <br />( <br />SEE PLAN <br />FOR CANT. <br />DETAIL aC� INTERIOR BEARING <br />SPLIT TO <br />SPLIT TO TIE <br />BEAMS TOGETHER <br />I <br />(6) <br />10dINTO BEAM -SEE <br />ROOF PLAN FOR MORE <br />�- <br />3 <br />i <br />INFO <br />( <br />SCALE: N.T.S. <br />WOOD TRUSS <br />SEE FLOOR PLAN FOR <br />A PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SEE FLOOR PLAN <br />FOR LUMSIZE <br />COLUMN SIZE & BASE <br />CONNECTION INFO <br />7/16" OSB FLITCH PLATE <br />REQ'D ONLY WHEN <br />STANDARD HEEL HEIGHT <br />SCALE: N.T.S. <br />&ADDI�IONAN <br />7/16" OSB FLITCH PLATE <br />SEE FLOOR PLAN FOR <br />SCHEDULEIPLANM <br />REQ'D ONLY WHEN <br />COLUMN SIZE & BASE <br />OPTION <br />A <br />INDICATED ON <br />OPTION <br />B <br />CONNECTION INFO <br />OPTION <br />C <br />SCHEDULE/PLANM <br />PORCH SLAB SEE <br />FOUNDATION PLAN <br />EXTEND <br />SLAB 1 1/2" <br />-(2) #5's CONT. T&B w/ <br />#3 STIRRUPS AT 4'-0" <br />WHEN DEPTH <br />EXCEEDS 30" <br />GRADE <br />- r <br />PORCH SILL 15 <br />SCALE: N.T.S. <br />SEE FLOOR PLAN SEE PLAN FOR <br />FOR BRG. OR REQ'D STAIR INFO. <br />NON-BRG. WALL IF CONCRETE STAIRS <br />FORMED & POURED <br />�W/ (1) #5 EACH STEP <br />2 <br />• w <br />- -- <br />4" <br />c~n <br />PORCH SLAB SEE—'-- <br />i <br />IL <br />FOUNDATION PLAN <br />=-'. ". <br />w <br />w <br />z <br />2 #5's CONT. T&B <br />w #3 STIRRUPS A <br />N _ <br />4'-0" WHEN DEPTH <br />EXCEEDS 30 <br />° <br />LOWER OR <br />Ilk <br />GARAGE SLAB <br />1'-4" <br />SEE PLAN <br />LARGE STEP <br />DOWN <br />'7� <br />1; <br />SCALE: N.T.S. <br />2X4 STUDS w/ SIMPSON <br />SP1 w/ (10) 10d NAILS <br />AT BASE SEE J/S6 FOR <br />MORE INFO. <br />EXTERIOR SHEATHING <br />ATTACHED PER <br />NAILINGSCHEDULE <br />2X4 BASE PLATE W/ <br />SIMPSON LSTA30 w/ <br />(22) 10d NAILS OR <br />SIMPSON MTS12 w/ <br />(14) 10d x 1 1/2" NAILS <br />TO FLOOR GIRDER <br />BELOW @ 16" O.C. <br />16" FLOOR SYSTEM FLOOR GIRDER <br />SEE PLAN FOR SEE PLAN FOR <br />DIRECTION CONNECTION <br />SECTION @ FLOOR <br />CONNECTION 22 <br />SCALE: N.T.S. <br />COMMON BM. TO POST ATTACHMENT KA� <br />SEE ROOF PLAN <br />FOR BEAM SIZE & <br />CONNECTION INFO. <br />SIMPSON (2) HTS20 w/ (14) <br />10d NAILS TYP. U.N.O. <br />SEE FLOOR PLAN FOR — <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />o, <br />o <br />CORNERLt <br />SEE FOUNDATION <br />PLAN FOR MORE INFO <br />5" <br />XX <br />COMMON BM. ATTACHMENT <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />EK <br />MIDDLE <br />BM. SPLICE OVER <br />CENTER OF POST <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />2X4 CONT. W/ (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />-TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL r7 <br />SCALE: N.T.S. <br />2x4 #2 SYP NAILER. NA <br />TO STUDS w/ (3) 16d @ <br />EACH STUD - TOENAIL <br />EACH TRUSS TO <br />NAILER w/ (3) 10d <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />w/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY w/ <br />(3) ROWS OF 16d NAILS <br />AT 24" O.C. <br />ROOF AND EXTERIOR SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />VERIFY FLOOR JOIST W/ RIM <br />BOARD OR FLOOR GABLE W/ <br />FRAMING PLAN <br />SIMPSON LUS26 w/ (8) 10d • <br />NAILS OR IF 2 PLY TRUSS SEE FLOOR FRAMING PLAN <br />SIMPSON LUS26-2 w/ (8) 16d AND J/S6 FOR MORE INFO. <br />NAILS TO LEDGER VERIFY WITH PLAN FOR <br />2X8 #2 SYP CONT. LEDGER W/ LOCATION AND DIRECTION <br />(4) 16d NAILS ATTACH NAILS (IF PARALLE SEE 2/D2 FOR <br />INTO END OF EACH FLOOR BLOCKING INFO) <br />TRUSS, 24" O.C. MAX. (AT EACH <br />SIDE OF G.T. INSTALL (4) NAILS MASONRY WALL <br />EACH SIDE) (TYPICAL) <br />SECTION AT LOW ROOF 9 <br />SCALE. 1/2' - 1 -0 <br />COMMON TRUSS <br />W/ INTERIOR BRG. <br />SEE PLAN FOR <br />CONNECTIONS <br />INFO. <br />USS/ <br />%2' CDX PLYWOOD OR 3/6" O.S.B. MIN. (2) 2x8 #2 SYP <br />SHEATHING REQ'D FROM BOTTOM HEADER. SEE Q/S4 FOR <br />OF WALL TO ROOF SHEATHING REQ'D CONNECTIONS <br />ABOVE W/ 8d NAILS @ 4" O.C. IN <br />FIELD, EDGES & BOUNDARIES ---------_.. - <br />SEE PLAN MAX. <br />24" STEPS - <br />SEE PLAN FOR OPT. <br />STAIR INFO. IF <br />CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />GARAGE OR ,- <br />LOWER SLAB <br />SEE PLAN - <br />SECTION <br />SCALE: N.T.S. <br />2X4 #2 SPF STUDS @ <br />12" O.C. W/ USP SPT22 <br />@ BASE & SPT24 @ <br />TOP <br />2x4 #2 SYP P.T. PLATE W/ <br />V EPDXY ANCHOR OR <br />J-BOLT OR %2' TITEN HD <br />ANCHOR @ 24" O.C. W/ <br />MIN. 6" EMBEDMENT I <br />MAIN HOUSE <br />SLAB <br />(2) #5's CONT. T&B <br />W/ #3 STIRRUPS AT <br />4`-0" WHEN DEPTH <br />EXCEEDS 30" <br />GARAGE MONO 21 <br />av { <br />W <br />Cn o <br />i w <br />s E9 p_ <br />cc m CZ <br />N R p s•- <br />ec <br />al <br />»c = <br />� v r2 <br />�+ o <br />.o <br />a0-AT, (7 W. <br />�� A <br />C=4 <br />LL <br />u4? e <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 Florida Building Code <br />- <br />Residential 7th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />x H <br />IN <br />�E <br />4 S 0p <br />° N N o <br />0 Sg Nco <br />�, _ co <br />60 <br />@ LL LL a <br />aZ <br />mc`:v d ai <br />.` % r go- <br />2o <br />h j fo - � 0 <br />W 05 co W <br />Z N Q <br />Ln Z <br />— N M Q <br />O <br />Z O U o h <br />�F, W ❑ ❑ <br />z N M <br />og <br />z s I <br />v =gI <br />V) z a <br />via <br />l <br />/{ [' C <br />TI V• w <br />_(D o Lu C) <br />-91 <br />r— cn <br />�i <br />C <br />U <br />O N <br />Q o <br />0 <br />oco <br />c".) <br />M <br />z <br />o <br />w <br />z <br />� <br />u <br />a E <br />E OV <br />zo <br />o <br />f <br />z <br />>o <br />Z® <br />od <br />co <br />�O <br />Uo <br />O <br />O< <br />Qz <br />O tr <br />�z <br />N <br />It <br />wo <br />¢ <br />w <br />< oz <br />U <br />'o <br />Z <br />3 <br />0< <br />Zo <br />¢o <br />WwLL <br />Q <br />�W <br />A <br />o <br />J <br />L. <br />}° <br />a <br />CID <br />M <br />00� <br />0 O <br />= <br />CM <br />'Cr' <br />cu <br />cu <br />0 <br />00 <br />L <br />T <br />:3 r <br />r <br />CN <br />f� <br />V1 J <br />~ <br />O <br />O <br />N <br />� <br />O <br />N <br />N <br />Q <br />�— <br />N <br />(i� LO <br />o <br />z <br />E r <br />is <br />a <br />U _j Q in <br />JOB <br />NO: 22-06454 <br />SCALE : AS NOTED <br />SHEET NO. <br />D1 <br />(MONO) <br />m <br />M <br />