My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6400 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6400 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 3:17:57 PM
Creation date
2/19/2025 2:46:30 PM
Metadata
Fields
Template:
Building Plans
Street #
6400
Location
Ten Acre Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
5344
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.- t <br />] <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A INDOOR <br />PANEL CENTER <br />NEMA1 <br />150 AMP/ <br />200 AMP <br />4 to lights & outlets <br />2to appliances and GFI <br />0to WH <br />to Range <br />to HVAC <br />MAOIN <br />150=2/0 <br />200=410 in 2" Conduit <br />20C amp <br />150 amp <br />UNDERGROUND Dis <br />SERVICE BY POWER CO.---_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 <br />4 Bare Cu Ground <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />j3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />1-01 <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />14) <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />DB <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />❑TV 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />IM <br />ELECTRIC METER <br />�_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />A <br />OPT. CEILING FAN <br />G9 <br />(1) PHONE LINE, (1) DATA PORT <br />III, 1.5" VTR <br />'I <br />I <br />I <br />I <br />� I <br />I <br />G� I I <br />I I <br />I I I I <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />FOR DISPOSAL <br />DEDICATED <br />RECEPTACL <br />FOR MICRO\ <br />RANGE HOC <br />PER SPECS <br />If <br />II <br />II <br />II <br />Il <br />OPTIONAL LIGHTING <br />SCALE: %4'=1'-0" <br />PER SPECS <br />ELECTRICAL PLAN -A <br />SCALE: %4'=V-0" <br />SWITCH FOR <br />DISPOSAL IN <br />CABINET <br />If 11 <br />II ALT II <br />I I AC PAD I I <br />Il 11 <br />L=====J <br />WP <br />OGFI <br />DISC. <br />1$ <br />C�D <br />W <br />O <br />d a <br />yc W <br />I= <br />U <br />— N <br />N `co a <br />Co <br />a <br />E <br />L <br />ca y <br />y CL <br />Cco <br />a <br />CV <br />CV <br />0 <br />CV <br />O <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's <br />signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />NN <br />W <br />a <br />vE <br />C) <br />8 <br />VOw <br />C', 0 <br />G <br />N <br />��?- �- <br />N <br />N <br />�rr-:R <br />C-4 Q <br />Q <br />� <br />C J LL W <br />JtLL a <br />Lu <br />Z <br />— O li Y <br />(0 C Cn <br />_r_�o 3:o <br />IIx <br />S O7 N O <br />W��6_j6] <br />m <br />ILW <br />ZOPINION= <br />u4 N Z Q r- <br />0 <br />N <br />O U U O <br />Z <br />on <br />El 11 <br />z N o <br />o <br />� N <br />z o � <br />r <br />lLn <br />M <br />Z a <br />c <br />W <br />(Dm <br />a <br />}, <br />a <br />W <br />O <br />W o <br />U <br />W J <br />~- — <br />ERig <br />ml <br />_ S <br />I <br />�4 <br />U�N <br />c U) Y <br />o <br />ti <br />O <br />C.0 <br />w <br />M <br />m ¢ <br />o <br />z <br />a <br />J <br />ILL. <br />Q. E <br />� o <br />z❑ <br />W o <br />> <br />Z <br />a <br />zp <br />Ca <br />{— <br />K <br />¢< <br />OU <br />O1 <br />Z <br />O E <br />ap <br />aZ <br />CV <br />Q) L <br />wo <br />¢ <br />�w <br />cn C: <br />o <br />.0 <br />z LL <br />0 J <br />0 <br />w <br />Z <br />N <br />Cn N <br />Q <br />pp <br />Z <br />ao <br />MEN <br />Q <br />LL <br />z <br />LLI <br />U <br />¢0 <br />Fr <br />1 <br />� <br />o2 <br />_0 <br />C,w` <br />Of <br />O <br />V <br />--Z <- <br />a = <br />r_ <br />C O <br />o <br />i <br />O <br />Ln <br />0 <br />a� <br />rn <br />m <br />m <br />0 <br />L <br />T <br />(Q <br />r <br />� r <br />r <br />O <br />(n U <br />v <br />N <br />f-�+ m <br />LO <br />O <br />Q <br />N <br />� <br />o <br />LO <br />T <br />Q <br />O <br />T <br />Eco <br />CD <br />o <br />co <br />T <br />ii 00 <br />Z <br />Z <br />E T <br />a)c <br />C <br />�' <br />0- <br />0 <br />¢ o <br />JOB <br />NO: <br />22-09408 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />,J—r T—TITT <br />
The URL can be used to link to this page
Your browser does not support the video tag.