Laserfiche WebLink
ELEC <br />METER <br />PANTRY <br />v <br />r � <br />.r <br />GFI <br />TO - <br />AM� <br />C <br />� GFI Al <br />30" A.F.F <br />4'-3" 5'-8" <br />KITCHEN <br />Ir _ <br />PANE <br />GFI AT <br />30" A.F.F. <br />6'-0" <br />GFI <br />DINING <br />ROOM <br />L <br />TWO CAR GARAGE <br />48 <br />i o <br />GFI <br />i <br />110V CLG <br />I <br />MNT. i <br />OUTLET <br />i <br />i <br />i <br />I _ <br />I O, <br />I O <br />Q <br />i <br />I <br />I <br />i <br />I F- <br />- — <br />L- - - - - - - - - - - - - - - - - - A <br />■ <br />A/C <br />DIS <br />M <br />HDMI <br />6'-1" I <br />LIVING <br />i ROOM <br />2'-11 3/4" <br />11011 <br />1 <br />o <br />CS <br />iTO 2NDI <br />FLR ELECIM <br />o GFI WI <br />N WP I <br />4'-8" <br />ENTRY­j ------- <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION A <br />1 /411 = 1 1-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST X FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2"AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />Gw'Itir <br />23pp <br />Sig rya' `�- <br />PS <br />v+ <br />e <br />Q�ans ,mp�`ape'��a P <br />O'�`p`, <br />�a\'-\ <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />m <br />SWITCH <br />4 1/2" <br />DOORJAMB DUPLEX cm <br />OUTLET ih <br />TRIM — <br />BASE --- <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />k <br />SMOKE DETECTOR <br />1'-0" <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />-69- SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />- 4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />-o DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />{�- CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />-{ WALL MNT FIXTURE <br />NOTE: <br />ND OPALEX - ALTERNATE <br />TUB/SHOWERCANS MAY BE <br />4� 50W PAR30 NFL 6" WHITE BAFFLE USEDIF <br />APPROVED BY <br />50W MR16 4" LOW VOLTAGE OWNER <br />�8 50W PAR20 NFL 4" MINI ROUND RECESS <br />�0 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />SMOKE DETECTOR <br />CU-182 UNDER CABINET 18" <br />CS-183 SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 1 48"CLG MNT WRAPPED FLUOR LIGHT <br />F-,24:R 24" VANITY LIGHTING <br />FFvF 36 :FuR 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />,Q EXHAUST FAN/LIGHT <br />Q EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />EM CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />® CEILING RETURN AIR <br />EM A/C REGISTER <br />® THERMOSTAT <br />110 SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />^` <br />; E <br />'M o <br />W L -= <br />0 iM N m <br />} <br />N <br />D p "' r> <br />V -0 -0 � M <br />A� -E r CO <br />W O <br />_D <br />Q <br />�^N` <br />V w Q� <br />E c <br />W <br />70 <br />L 0 <br />-0 <br />a <br />(�W <br />w <br />W Q W J w 2 � 0 <br />Wo=�J�o�W�LL()ooJO <br />Q Q <br />U <br />F- <br />Joo zLLLLoz�ool- <br />o(nw�ozowoomzz <br />aQ <br />0 <br />0O <br />CO o <br />z <br />COWa�(nWWw(ALLd'QQ�J <br />QoW° � z Wo�0 <br />°Ex 0 :3 0yz <br />Q Q <br />< <br />LL O LL <br />!f <br />O <br />O <br />Z N <br />OW <br />z <br />F-7 cM O <br />Q w M rl- <br />LL <br />z <br />< w < U� <br />Q. M <br />O <br />Z V <br />w <br />W <br />JQ <br />A <br />O <br />l <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />O <br />O <br />N <br />O <br />N <br />O <br />N <br />N <br />N <br />N <br />N <br />o <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />� <br />N_ <br />N <br />O <br />� <br />00 <br />o <br />O <br />O <br />r- <br />C, <br />o <br />N <br />o <br />I <br />I <br />' <br />z <br />O <br />NLO <br />co <br />w <br />0 <br />0 <br />0 <br />0 <br />0 <br />! <br />i <br />L> <br />N <br />.'i <br />4 <br />6 <br />1 <br />Cr <br />M <br />VJ <br />}~ <br />ZZ <br />W <br />O <br />�"ar <br />ll.l <br />? <br />O O <br />O <br />V <br />W <br />VUFn <br />=)Z> <br />ow- <br />f-o <br />Q <br />Z <br />wx� <br />�■ <br />t— <br />I w < <br />rl <br />= <br />Wow <br />N <br />O <br />~moo <br />r*4 <br />zz o = <br />QF-� <br />N <br />O <br />Zito <br />z <br />U <br />CLZu- <br />u_ <br />az <br />� <br />Z <br />F- <br />U <br />� <br />O <br />IL <br />_p <br />W <br />z <br />z <br />Z <br />w <br />W <br />J <br />0 <br />0 <br />LAST PLOT DATE <br />. " <br />July 21, 2022 <br />Z <br />0 <br />1ST FLOOR <br />ELECTRICAL PLAN A <br />