Laserfiche WebLink
tT <br />3 <br />m <br />rn <br />00 <br />c'V <br />L0 <br />v <br />o- <br />0 <br />N <br />J <br />M <br />U <br />I <br />m <br />N <br />LO <br />L <br />4 <br />7 <br />0 <br />Z2 <br />cmo <br />J <br />t`7 <br />CD <br />0 <br />1 <br />to <br />L <br />Q <br />C <br />to <br />:Q9 <br />Q <br />6, <br />c <br />Q <br />N <br />Np <br />4 <br />E <br />y <br />E <br />x <br />c <br />9 <br />W <br />LF- <br />E <br />0 <br />U <br />I <br />U <br />0 <br />a <br />i <br />a <br />a <br />U <br />L. <br />LO <br />0 <br />0 <br />a <br />N <br />NLO <br />0 <br />a <br />m <br />crvi <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED, LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />o lights & ouAets <br />D appliances and GFI <br />)WH <br />Range <br />HVAC <br />METER II <br />MO U <br />s0=2/0 <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217, <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable, <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17,1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />f-[B]P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />i9 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�]M <br />ELECTRIC METER <br />_a <br />ELECTRIC PANEL <br />_I <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />r------------ ------------------------------- <br />I <br />I <br />I . <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br />UPPER FLOOR ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4"=1'-0" <br />C <br />® <br />7 W <br />O <br />a �,o <br />'+tn � _t'V L <br />� c <br />CD <br />c c5 <br />,rE. <br />�o <br />L <br />0 <br />N <br />N <br />0 <br />N <br />M <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural <br />plans and specifications contained <br />within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />MM N <br />W <br />Q <br />0 E <br />co 8 <br />U <br />O <br />o rn <br />OnW <br />0 <br />� �COS <br />�rNia�2 <br />� <br />V% <br />Q <br />0Z25s <br />C J 5 <br />J 10- LL 55 <br /># LL <br />It-w <br />a <br />a <br />L f0 V <br />00 <br />W��pjO� <br />o <br />Z <br />U U <br />U) Z <br />m w- <br />d <br />cN,� <br />OU <br />t— <br />00 <br />ZN <br />W <br />1710 <br />N M <br />O c) <br />z m <br />z o a <br />¢ v <br />J <br />r, <br />U0 <br />z <br />0 <br />N <br />W <br />U <br />0 <br />w o <br />V) C <br />�N <br />� a <br />CCJ <br />'— <br />U c <br />w <br />low <br />F— J E <br />t0 O <br />=� <br />U o y <br />° <br />o <br />C.0 <br />w <br />M <br />M <br />w <br />p <br />Z <br />Z <br />< <br />(OE <br />E o <br />Z. <br />�0<� <br />O LL <br />a <br />Z® <br />o a <br />fd <br />xo <br />UO <br />p <br />0 ¢ <br />ZN <br />0 E <br />ao <br />40 <br />az <br />¢W <br />L <br />M <br />C <br />�o <br />Zz z <br />OY <br />U <br />WmW <br />F O <br />O <br />z <br />Z <br />Z <br />C <br />� <br />J <br />N <br />m <br />F <br />Q W <br />(� <br />N z <br />< <br />Z Z <br />o <br />N C <br />555 <br />oa <br />LL <br />a <br />� W <br />WQ. <br />w <br />0 <br />WF <br />�O <br />a x <br />0. <br />°3 <br />C:) <br />Lo <br />' <br />L / <br />m <br />Q <br />0 <br />� <br />� <br />T <br />j r <br />N <br />� <br />Y <br />Y <br />T_ <br />o <br />\V� <br />W <br />m <br />Li/ <br />}j <br />4-1 <br />0) <br />�I <br />N <br />0) <br />00 <br />p <br />LO <br />00 <br />CV <br />Q <br />N <br />T <br />hi <br />T <br />CM <br />o <br />m <br />� T <br />y LO <br />Z <br />Z <br />E <br />y <br />m <br />c <br />a <br />U <br />Q p <br />JOB <br />NO: <br />22-06463 <br />SCALE : <br />AS NOTED <br />SHEET N0. <br />4.1 <br />