ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />M <br />C <br />20C <br />15C <br />UNDERGROUND his <br />SERVICE BY POWER CO.----- <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 JJJ <br />GENERAL ELECTRICAL NOTES: I Typical 150-200 Amp <br />NOTE: ELECTRICAL MATERIAL AND <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UT <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance With UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed Within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shalt not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The Width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />w.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.i. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />NiF <br />HALF -SWITCHED DUPLEX OUTLET <br />® <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -MAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />lO <br />EXHAUST FAN <br />'t <br />Iwo <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />a <br />150AI200A INDOOR <br />PANELCENTER <br />#14 to rights & outlets <br />NEMA t #12 to appliances and GFI <br />150 AMP/ <br />200 AMP #10 to W wn ��` I' <br />10 98 to Range <br />Is k8 to HVAC <br />FIRST FLOOR ELECTRICAL PLAN - ELEV-Al <br />SCALE: Y4'=1'-0" <br />c%1 <br />N <br />� <br />0 <br />rr+•a <br />� <br />s <br />0 t`rwO <br />c "- c- <br />e/tr_49.'N <br />.L <br />t!% - C A <br />4-� ' <br />s1 <br />rr ' cc <br />``apt d <br />Aa <br />a <br />C u <br />cs <br />a+ <br />CS <br />cm <br />N <br />0 <br />N <br />M <br />ci <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />0 <br />W <br />a <br />E <br />o 8 <br />Lq <br />to g N r <br />d5 <br />rjnrZV 0 "' <br />M <br />a <br />N v th I <br />J <br />LL <br />� <br />11 <br />13 <br />tU. <br />Z6O7 <br />So <br />r a 5 <br />Wtm <br />^a <br />CP m <br />W <br />Z <br />N N Z d J <br />Zo <br />cal v to <br />W <br />❑❑ <br />Z o d <br />— <br />a <br />13 <br />V I <br />N <br />N <br />�4­0 <br />(D <br />u�, <br />W- <br />O <br />W g <br />�Nco <br />pp Y <br />N � <br />M <br />h <br />W <br />Z <br />a <br />E <br />55 <br />Uj � <br />-go <br />a <br />[�O U <br />o <br />U <br />06 <br />00 <br />U <br />6� <br />Z <br />O E <br />N t0 <br />ao <br />a <br />0g <br />w Z <br />d i <br />wo <br />�o <br />a� <br />m0 <br />Z <br />aK <br />0� <br />Z 0 <br />U <br />Z <br />j <br />�� <br />2 <br />CD <br />Nr <br />J <br />�C <br />>� <br />L LO <br />Q <br />0 <br />� Mj <br />j <br />Cr O <br />j <br />Y <br />M <br />W <br />m <br />/� <br />L,` / <br />Q <br />4_0 <br />O <br />N <br />0) <br />I <br />N <br />N� <br />N <br />T <br />L/� <br />J <br />M <br />Lr) <br />M <br />d' <br />o <br />z <br />c <br />M <br />E 1"^ <br />N <br />ai <br />m <br />0- <br />U _ <br />v <br />Q a <br />c <br />JOB <br />NO: <br />22-06467 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />