My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6502 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6502 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:58:15 PM
Creation date
2/19/2025 2:49:28 PM
Metadata
Fields
Template:
Building Plans
Street #
6502
Location
Wagon Trail St
Contractor
Lennar Homes LLC
Building Plans - Permit #
19502
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ALL WORK SHALL COMPLY W'TH PREVAIUNG <br />CODES FLORIDA BUILDING CODE <br />NATIONAL ELF CTRIr CODE <br />AND THE CITY ZEPIiYRFiILLS <br />ORDINANCESS3S <br />wit 4i„r ` A'i.i:Y <br />— <br />o <br />_ <br />a <br />ILL 77] D 0 p 0 E] <br />a <br />■ ■ ■ ■ �D� ■ <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS <br />COVER SHEET <br />1 <br />FLOOR PLAN <br />2 <br />INTERIOR ELEVATIONS <br />3.1 <br />EXTERIOR ELEVATIONS <br />3.2 <br />EXTERIOR ELEVATIONS <br />F1 <br />FOAM DETAILS <br />4 <br />ELECTRICAL PLAN <br />5 <br />ROOF PLAN <br />6 <br />FOUNDATION PLAN <br />7 <br />ROOF FRAMING PLAN <br />8 <br />LINTEL DETAILS <br />SIN <br />STRUCTURAL NOTES <br />SN1 <br />DETAILS <br />STEM DETAILS <br />S4 <br />DETAILS <br />S5 <br />DETAILS <br />SS <br />RETROFIT DETAILS <br />D1 <br />SECTIONS & DETAILS <br />WP <br />WATERPROOFING DETAILS <br />PA1.0 <br />PRODUCT APPROVAL NUMBERS <br />PA1.1 <br />PRODUCT APPROVAL NUMBERS <br />ABBREVIATIONS <br />PA1.2 <br />PRODUCT APPROVAL NUMBERS <br />PA1.3 <br />PRODUCT APPROVAL NUMBERS <br />A.B. Anchor Bolt <br />Abv. Above <br />A/C Air -Conditioner <br />ADJ. Adjustable <br />A.F.F. Above Finished Floor <br />A.H.U. Air Handler Unit <br />ALT. Alternate <br />B.A. Base Cabinet <br />BF Boold Door <br />Bk Sh Bookshelf <br />Bm. Beam <br />Bot. Bottom <br />B.P. Bypass door <br />BRG. Bearing <br />Cir. Circle <br />Clg. Ceiling <br />CJ Control Joint <br />Col. Column <br />Comm. Community <br />�' <br />Comp. Compressor <br />C.T. Ceramic Tile <br />D. Dryer <br />DB Door Bell <br />Dec. Decorative <br />Ded. Dedicated Outlet <br />Dbl. Double <br />Dia. Diameter <br />Disp. Disposal <br />Dist. Distance <br />D.S. Drawer Stack <br />D.V. Dryer Vent <br />D.W. Dishwasher <br />Ea. Each <br />E.W. Each Way <br />Elec. Electrical <br />Elev. Elevation <br />Ext. Exterior <br />Exp. Expansion <br />FBC Florida Building Code <br />Fin. Flr. Finished Floor <br />F.G. fixed Glass <br />Flr. Floor <br />Fdn. Foundation <br />Ar Sys Floor System <br />F.P. Fireplace <br />F.O.M. Face Of Masonry <br />Ft. Foot/ Feet <br />Ftg. Footing <br />FIX Fixed <br />Galy. Galvanized <br />G.C. General Contractor <br />G.F.I. Ground fault Interrupter <br />G.T. Girder Truss <br />Hdr. Header <br />Hgt. Height <br />HB Hose Bibb <br />K/ Interior <br />KM/all Kneewall <br />K.S. Knee Space <br />Laun. Laundry <br />Lay. Lavatory <br />L.F. Linear Ft. <br />LL Lintel Length <br />LT. Laundry Tub <br />Mas. Masonry <br />Max Maximum <br />M.C. Medicine Cabinet <br />Mfgr. Manufacturer <br />Micro. Microwave <br />Min Minimum <br />M.L. Microlam <br />Mir. Mirror <br />Mono Monolithic <br />N.T.S. Not to Scale <br />Opn'g. Opening <br />Opt. Optional <br />Pc. Piece <br />Ped. Pedestal <br />PH PHONE <br />P.L. Parallam <br />PLF Pounds per linear foot <br />Pit. HI. Plate Height <br />Pit Sh. Plant Shelf <br />PSF Pounds per square foot <br />P.T. Pressure Treated <br />Pwd. Powder Room <br />Rad. Radius <br />Ref. Refrigerator <br />Req'd. Required <br />Rm. Room <br />Rnd. Round <br />RID. Rod and Shelf <br />SD. Smoke Detector <br />S.F. Square Ft. <br />Sh. Shelves <br />SHT Sheet <br />S.L. Side Lights <br />S.P.F. Spruce Pine Fir <br />Sq. Square <br />S.Y.P. Southern Yellow Pine <br />TB Towel Bar <br />Temp. Tempered <br />Thik'n. Thicken <br />T.O.B. Top of Block <br />T.O.M. Top of Masonry <br />T.O.P. Top of Plate <br />TR TOWEL RING <br />TP TOILET PAPER <br />Trans. Transom Window <br />Typ. Typical <br />U.C. Under Counter <br />UCL Under Cabinet Lighting <br />U.N.O. Unless Noted Otherwise <br />V. Shower Valves <br />VB Vanity Base <br />Vert. Vertical <br />V.L. Versalam <br />VTR Vent through Roof <br />w Washer <br />W With <br />W/C Water Closet <br />W.A. Wedge Anchor <br />Ad Wood <br />WP Water Proof <br />REVISIONS <br />�► <br />Z1 <br />I&T_ <br />71 <br />08-20-15 1.00 NEW BASE PLAN <br />12-8-15 2.00 FRAME -WALK REVISIONS <br />12-28-17 3.00 2017 FBC UPDATES <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />FOR SINGLE STORY HOMES <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />FOR 2 STORY HOMES <br />THIS DRAWING AND DESIGN IS VALID <br />FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />CURRENT CODE IS VALID <br />Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />Payments will be made in accordance to the terms of the <br />agreement. <br />(D <br />2 M <br />— O <br />� QQQ <br />l a <br />V) z <br />cn 0 <br />LU <br />� p <br />O w <br />V) <br />FE <br />o <br />Cn 0 <br />o 0 <br />~ <br />N M <br />m oM <br />O o 70 M <br />_ ai <br />L Lt00 <br />U <br />_6 <br />Q o <br />P <br />¢ rn <br />rn Q 0 <br />® <br />® <br />NN C�V <br />0 <br />0N°� <br />M <br />N <br />d•\S N <br />• O <br />u.. <br />u <br />r�. <br />®c� .mac <br />L <br />\• <br />Z LL <br />m� <br />W¢,M, F <br />w <br />o� <br />To the best of the EngineeA $4N?,✓)edge, i r nd <br />belief, the structural plans and sKINQ t fined <br />within these drawings comply with the 2017 lorida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />CD <br />Z C(4 <br />0 � � <br />00 <br />> M <br />Q U) <br />a cn • � � <br />Z <br />< C LL <br />Q ^ <br />O <br />a00U0- <br />Z § <br />Z � <br />WJ <br />l00 <br />Milli <br />0z <br />� <br />H <br />CeE <br />z¢a <br />f¢ <br />w¢�- <br />UZOp <br />Ww� <br />� ZZ <br />$,HW <br />>�ga <br />W <br />i;wLLN <br />O <br />o uLn <br />w <br />ZZ <br />_ <br />dU <br />Zz <br />P.- <br />LU <br />F <br />o <br />' <br />'-� <br />O <br />v <br />U <br />a <br />LLU <br />� <br />aRo <br />F <br />U .0, <br />oaoa <br />nj <br />za <br />¢ <br />a3 <br />Z <br />N <br />auo <br />w <br />.J <br />l� <br />ri <br />LcJ.J <br />G <br />Q <br />di= <br />¢ <br />Z <br />a <br />v oZ UU <br />2 Uzi <br />Q <br />a <br />aWZ <br />d- <br />`n <br />Z <br />of <br />a n <br />m <br />o <br />Z <br />w <br />�o <br />dW <br />O <br />g <br />= <br />V__4 <br />a <br />cn <br />SCALE : AS NOTED <br />DATE : 12/28/2017 <br />TECH: ERAND <br />VERSION NO. 10 <br />SHEET NO. <br />C S <br />
The URL can be used to link to this page
Your browser does not support the video tag.