Laserfiche WebLink
CROSS BRACING DETAIL (TYP.)r1 <br />SCALE: 1/2" = V-0" <br />TRUSS NOTES: <br />1. WOOD TRUSS ERECTOR SHALL- PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 <br />CONV. FRAMED RIDGE <br />MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER <br />w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE <br />IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST <br />PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D <br />NAILS AT EACH TRUSS INTERSECTION. <br />CB <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />VV/ G- I UU llU I I I r1UJV V V LL7 <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />- 2x8 BLKING. NAILED @ EACH <br />SIDE w/ (3) 12d NAILS WHEN <br />REQUIRED w/ (2) USP HTW20 <br />W/ (14) - 10d X 1 1/2" EACH <br />v 11 [ * IT[ I-[ <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT —Tg <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. Dg g <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />MAX &EACH END ALTERNATE BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP — <br />DIRECTION TYP. � <br />CHORD AT ALL HAND FRAMED AREAS TYP. 4. <br />SEE ROOF PROVIDE 2X4 MIN. BLOCKING AT <br />PLAN SHEATHING Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />2X4 BLOCKING TYP. <br />BETWEEN TRUSSES TRUSS <br />SECT. A <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING JACK <br />MAX 24" SPAN (EITHER USSES HIP <br />SIDE OR BOTH IF REQ'D) G.T <br />(2) 12D NAILS —J <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />USP LSTA18 <br />VERTICAL SCAB CENTERED @ <br />2 x 6 #2 SPF 48" O.C. SPLIT TO TIE <br />W/ (4) 10d TOP & BEAMS TOGETHER <br />BOTTOM OR USP RT7 <br />OR HCLR/LL W/ 8 - 8d <br />IN PLACE OF (4) 10d <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2x4 SPF 2 <br />(2) #7X 3-1/2" WOOD <br />SCREW EACH TRUSS <br />OR USP RT7 @ 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />SCALE: 1 /2"=1'-0" <br />USP HD4101F BUCKET <br />SEE ROOF PLAN Fi <br />MORE IN <br />(2) 2x8 #2 SYP W <br />7/16" O.S.B. FLIT <br />PLATE TOP @ TI <br />BRG. <br />TYPIC <br />WALL <br />NOTE: PENDING BEAM <br />BEARING LOCATION, THE <br />BEAM CAN SIT ON TOP OF <br />COLUMN W/ (2) HTW20 <br />STRAPS <br />USP JUS46 OR JUS46IF <br />BUCKET TO COLUMN <br />SUPPORT COLUMN BUILT-UP <br />(2)-2x4's OR 4x4 W/ (2)-10d <br />NAILS @ 8" O.C. EACH PLY <br />(SHOWN AS 4 x 4) <br />(2) USP HTA20's <br />w/(10)-10d x 1 1/2 EA. TO COL. <br />ALT: (2) USP MSTAM36 <br />STRAPS CENTERED <br />w/(13)-10d NAILS Ea TO COL. <br />TIE BEAM <br />BEAM a@ RAISED ENTRY <br />MASONRY WALL 4 <br />SCALE: 1/2" = V-0" <br />SEE PLAN L. <br />FOR CANT. <br />SEE FLOOR PLAN FOR <br />COLUMN SIZE & BASE 7/16" OSB FLITCH PLATE <br />SEE FLOOR PLAN CONNECTION INFO REQ'D ONLY WHEN <br />FOR COLUMN SIZE INDICATED ON BM. <br />& ADDITIONAL INFO. SCHEDULE/PLAN <br />7/16" OSB FLITCH PLATE SEE FLOOR PLAN FOR <br />REQ'D ONLY WHEN COLUMN SIZE & BASE <br />OPTION A SC EDULDE/PLANM OPTION B CONNECTION INFO OPTION C <br />COMMON BM. TO POST ATTACHMENT KA <br />SEE ROOF PLAN <br />FOR BEAM SIZE & SCALE: 3/4"=1'-0" <br />CONNECTION INFO. BM. SPLICE OVER <br />CENTER OF POST <br />I SEE PLAN FOR /6. <br />EXTERIOR <br />ATTACHED <br />SCHEDULE <br />JACK TRUSS (AS SHOWN) <br />OR GABLE END SEE TRUSS <br />LAYOUT <br />CLIP EACH TRUSS <br />(SEE ROOF PLAN <br />FOR TYPE) <br />FRAME OUT TO <br />BLOCK EDGE <br />SEE DETAIL 4/D1 <br />FOR BEAM SIZE <br />2x SPF #2 <br />AT 16" O.C. <br />29 <br />BUILDER FRAME <br />LP RADIUS <br />AS REQUIRED <br />KNEEWALL ENTRY FRONT WALL s <br />SCALE: 1/2" = V-0" <br />2x4 #2 SYP NAILER. NAIL - <br />TO STUDS w/3-16d @ <br />EA. STUD, TOENAIL EA. <br />TRUSS TO NAILER w/3-10d <br />ROOF AND EXTERIOR <br />SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />DIAGONA <br />N„k <br />2x8 #2 SPF RIDGE BEAM <br />U: <br />AT 8'-0" <br />MAX <br />WOOD <br />TRUSS <br />2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />USP ST18 <br />USP <br />ST18 <br />A <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />TYP. U.N.O. <br />SEE PLAN FOR TYP. <br />U.N.O. <br />• <br />THAN 4FT @ 2'-0"0.C. MAX. w/ (3) 10d <br />SEE FLOOR PLAN FOR <br />CANT. IF <br />INDICATED <br />USP JU26 OR IF 2 PLY <br />COMMON TOENAILS TO RIDE BEAM <br />COLUMN SIZE & <br />TRUSS USP JUS26-2 <br />SEE FLOOR FRAMING <br />2X4 CONT. AT <br />CONC. MASONRY <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />TRUSS TO LEDGER <br />2X8 #2 SYP CONT. LEDGER w/ <br />PLAN AND J/S6 FOR MORE <br />T & B CHORD <br />STEEL OR WOOD <br />BEARING <br />MIDDLE <br />(4) 16d NAILS ATTACH NAILS <br />INFO. VERIFY WITH PLAN <br />SUPPORT <br />° ° <br />INTO END OF EACH FLOOR <br />FOR LOCATION AND <br />° <br />TRUSS, 24" O.C. MAX. (AT <br />DIRECTION (IF PARALLE <br />EACH SIDE OF G.T. INSTALL <br />SEE 2lD2 FOR BLOCKING <br />A -A ALTERNATE BLOCKING <br />CORNER d <br />(4) NAILS EACH SIDE) <br />INFO) <br />SEE <br />FOUNDATION <br />L4 <br />DETAIL a@ INTERIOR BEARING <br />PLAN FOR MORE INFO <br />MASONRY WALL <br />(TYPICAL) <br />3 <br />J <br />SCALE: 1/2" = V-0" <br />COMMON B M ATTACHMENT �18 <br />WOOD TRUSS <br />. <br />A <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SCALE: 3/4"=V-0" <br />SECTION AT LOW ROOF 9 <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />STANDARD HEEL HEIGHT <br />SCALE:1/2"=1'-0" <br />SCALE: 1 /2"= V-0" <br />VAR I ES <br />2x STUDS @ 16" O.C. <br />ROOF SHEATHING <br />SEE 1/S5 FOR <br />SEE PLAN FOR <br />/ U @ <br />ATTACHED PER <br />ADDITIONAL <br />81 NAILS AT <br />VALLEY TRUSS <br />BASE & SPT24 @ TOP <br />2x4 #2 SPF BRACING @ <br />NAILING SCHEDULE <br />EXTERIOR SHEATHING <br />OUTLOOKER <br />INFO. <br />4" O.C. <br />INFO. <br />2x BLOCKING BETWEEN <br />16" O.C. W/ (4) 12d <br />COMMON TRUSSES. <br />ATTACHED PER <br />STUDS TO TRUSS W/ (2) <br />TOENAILS TO TOP <br />SEE TRUSS PLAN <br />2x4 STUDS W/ USP <br />NAILING SCHEDULE <br />12d TOENAILS EACH END <br />STRUCTURAL SHEATHING <br />PLATE & (2) 12d END <br />MIN. (2) 2x4 <br />FOR CONNECTION <br />SPT22 @ BASE SEE <br />( BETWEEN TRUSSES (2) <br />12d NAILS TO EACH <br />ATTACHED PER NAILING <br />NAILS TO TRUSS <br />BOTTOM CHORD <br />SPF TOP <br />INFORMATION. <br />J/S6 FOR MORE <br />INFO. <br />LOW ROOF/WALL <br />VERTICAL STUD) <br />SCHEDULE <br />PLATE <br />TRUSS <br />TRUSS <br />T <br />SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />2x BASE PLATE W/ (2) 12d <br />VARIES W/ <br />VARIES SEE PLAN <br />FOR WALL LOCATION <br />2x4 BASE PLATE W/ <br />1/2" PLYWOOD <br />NAILS @ 16" O.C. ALONG W/ <br />USP MTW12 TO BLOCKING <br />ROOF SLOPE <br />USP LSTA30 OR <br />MTW12 TO FLOOR <br />(2) 16d NAILS TO <br />BELOW @ 16" O.C. <br />WOOD WALL <br />GIRDER BELOW @ 16" <br />EACH COMMON <br />OR TRUSS. <br />2X4 CONT. W/ (2) <br />MIN. 2x4 #2 SPF STUDS @ <br />O.C. <br />TRUSS/ FRAMING <br />TYP TOP & BOTTOM <br />SEE PLAN <br />16d COMMONS <br />16" O.C. W/ EXTERIOR <br />NAILS EACH <br />SHEATHING ATTACHED <br />xx <br />STUD TYP. T&B <br />PER NAILING SCHEDULE & <br />MASONRY WALL BELOW: USP <br />PLYWOOD <br />(3) 12d TOENAILS TO <br />a<. <br />HTA16 @ 4'-0" O.C. TO GABLE <br />FLOORING <br />TRUSS OR <br />OIL SEE PLAN FOR <br />PLATE BELOW <br />MASONRY WALL <br />TRUSS BEAM BELOW: USP <br />ROOF SYSTEM <br />TOP OF WALL <br />; <br />OR BEAM <br />HTW20 @ 4'-0" O.C. TO GABLE <br />MIN. 2x4 #2 SYP P.T. PLATE <br />16" FLOOR SYSTEM FLOOR GIRDER <br />SEE TRUSS PLAN <br />a<. <br />TRUSS <br />W/ 1/2"X8" EPDXY ANCHOR <br />SEE PLAN FOR SEE PLAN FOR <br />a <br />COMMON TRUSS <br />LOW ROOF TRUSS W/ <br />(2) 2x6 BLOCKING UNDER FLOOR G.T. <br />MASONRY WALL SEE <br />@ 3" FROM EACH END & <br />DIRECTION CONNECTION <br />SEE ROOF <br />RAISED BOTTOM CHORD <br />2nd FLOOR WALL W! USP SEE PLAN <br />PLAN FOR MORE <br />16" O.C. MAX. <br />as <br />FOR CONNECT ON <br />EXTENSION SEE TRUSS <br />JUS24-2 EACH END <br />SHEAR TRANSFER <br />INFO. <br />ep <br />SECTION FLOOR <br />MANUF. SPEC'S FOR <br />@ <br />CONNECTIONS TO G.T. <br />EXTERIOR. WALL � <br />SECTION <br />ENTRY('8_"*'�CONNECTION <br />22 <br />SECTION <br />AT HIP GABLE 12 <br />SECTION @ BUMP OUT �39 <br />SCALE: 3/4" = V-0" <br />SCALE: 3/4" = V-0" <br />SCALE: 3/4" = V-0" <br />SCALE: 3/4" = V-0" <br />SCALE: 3/4"=V-0" <br />��j <br />DETAILS & SECTIONS <br />NMI <br />C9 <br />z� <br />—o <br />z13J <br />z <br />Aff�� <br />V) CD <br />Q) C <br />W <br />t'6 p <br />0 Lij <br />cn <br />C6 <br />o a <br />m <br />V <br />W <br />8 <br />N M M <br />CCh U M <br />N -0 M <br />0"0 <br />_ <br />C.) a' <br />0 1 <br />- ao <br />¢ m <br />- ao <br />K E B o 1►ti <br />It <br />!ll <br />®®T <br />® <br />' hS <br />�. <br />e v _Y� <br />M' � N U)11Wci <br />ay. <br />O <br />— <br />to . <br />N ^i � <br />�'-j,Jue s <br />T, F O <br />P* O44 <br />/�+a,, <br />LL3W'ij� <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />ON <br />Z <br />O�t� <br />i>-IMO <br />M <br />Q U-) rO Lr <br />a .L n <br />V) <br />Ln <br />Q N <br />LL <br />H C)- <br />U Q00 <br />Z M <br />C:) <br />WJ <br />J <br />oZ <br />�o <br />w <br />zd <br />f a <br />~ <br />Y <br />w¢�� <br />r pZp U <br />W w <br />FZ <br />T Q W Z <br />a�iro <br />U Lu CN <br />Z <br />oZ <br />Zo <br />0 <br />1U <br />Z <br />o <br />U <br />LJJ <br />o <br />Z <br />> <br />T <br />O <br />06 <br />J Q <br />ui <br />V <br />U) <br />_J <br />L� <br />0"z <br />�Fo <br />aUO2m2 <br />F"— <br />X 8 <br />W <br />N <br />OR! <br />� J <br />Q <br />8a�o <br />Z <br />Z <br />N <br />w <br />W <br />J <br />Lf) <br />Ti <br />W <br />Li0<1 <br />V7~ ZU <br />g�a <br />ri <br />d- <br />2:Q <br />¢ <br />z <br />Q <br />Wz <br />^ <br />L / <br />Z <br />1, <br />zW <br />O <br />00 <br />S <br />'r' <br />W <br />=U.J <br />J Z <br />¢Z <br />r 7l <br />T__I <br />a <br />cn <br />SCALE : AS NOTED <br />DATE : 12/28/2017 <br />TECH: ERAND <br />VERSION NO. 10 <br />SHEET NO. <br />D1 <br />