40 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 — <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />ppper to lights & outlets <br />opper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />i Alu <br />GENERAL ELECTRICAL NOTES. Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />a <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />PM <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT, CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />F <br />AC PAD <br />DISC. <br />WP <br />GFI <br />M <br />M <br />W.I.C. ):�_ ` <br />I <br />I ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />i LIGHT PRE -WIRE <br />OW NEE R' <br />SUITE <br />\ I <br />k � <br />VERIFY METER LOCATION <br />WITH BUILDER <br />JR� <br />EDROOM 2 BEDROOM 3 /ROUGH -IN FOR <br />ROUGH-ING. FOR OPT. CLG. FAN/ <br />OPT. CLG. FAN/ <br />LIGHT PRE-WIRL� i% ` LIGHT PRE -WIRE <br />ROUGH -IN ' / �� �% <br />GHTPRE-WIRE �tD*OM 4 <br />G lr 1�) <br />\ m m1\ � S.D S.D <br />/ O O <br />DEDICATED RECEPTACLE <br />O FOR MICROWAVE RANGE C.M <br />HOOD PER SPECS-- -- <br />DW I SINK w/ <br />1- ti _o TDISP ti <br />:IS.)D � O� � L Still.. _ � <br />-r----- -- — — — - <br />I L_ I I — :/ <br />I LiEl <br />I � / <br />I � / <br />/ ROUGH -IN F�R / <br />/ OPT. CLG. F N/ LIGHT / 7-0" <br />/ PRE -WIRE I / <br />---------- <br />PENDANT AS <br />/ PER SPECS <br />FAMILY ROOM <br />CAFE <br />/ <br />/ <br />/ <br />OPT <br />MW <br />W <br />--- <br />OW F <br />c) a I <br />I <br />j U I <br />I <br />LL I I <br />Cr U I <br />W <br />W 2-CAR GARAGE <br />I @ 44" <br />A.F.F. <br />GARAGE 1 I <br />LIGHT AS I GARAGE <br />PER SPECS I DOOR <br />GFI <br />I <br />I <br />r i I n I <br />I! 11 <br />I 1 1/I I <br />L------------ <br />GFI @ 44" A.F.F. <br />A IRRIGATION <br />'WWp <br />GFI � <br />ENTRY <br />I <br />I <br />MAIN ELECTRICAL PLAN <br />SCALE: %4'=V-0" <br />C9 <br />z m <br />_ d <br />z� <br />Q <br />J <br />a <br />V) CD <br />LU <br />ru p <br />OLu <br />E <br />C%) � <br />NZ <br />o 0 <br />M <br />L U E <br />rn M <br />C c6 Cl) <br />O O N <br />awin) <br />CJ N <br />- <br />L co <br />3e <br />G �Y <br />" I` <br />u� Off_ <br />Q Cn <br />Q Ci <br />�10eq <br />tun- <br />oZ <br />od <br />zJ <br />��Z� <br />rcg <br />— <br />'N <br />J <br />W M =o <br />WLt- <br />laLU <br />Z U a o <br />z <br />o <br />_� <br />�ro o o <br />co_� <br />m <br />Z H�mmw <br />LL <br />¢ M <br />W a N 42 <br />o <br />O <br />O U <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />ON <br />Z <br />0 a) n <br />> M 00 <br />(n <br />M <br />Q'pLr) <br />a to <br />Z� <br />fl. ^ <br />, L ro <br />V Q00 <br />a �" <br />z� <br />� <br />WJ <br />� <br />d- <br />Mj <br />oZ <br />Eo <br />WZ <br />Z a <br />fa <br />F- <br />wa�QE <br />oo8o <br />Z w W 0 <br />�=)H <br />2 <br />W,aw0m <br />Z <br />Z <br />O 8 <br />O <br />Q <br />J <br />o� <br />Z= <br />}o <br />� <br />aZ <br />T� <br />S <br />O <br />Q <br />U <br />�3 <br />O <br />U <br />�Z <br />a <br />U <br />LLJ <br />_j <br />X <br />>9 <br />8 <br />Y' <br />Z <br />tjo" <br />N <br />_ <br />Q <br />�'-"'ELL ZJ <br />�aa3 <br />a <br />d" <br />o� <br />Z <br />N <br />u_0�o <br />W <br />wa u_ <br />aa�o <br />—I <br />rl <br />LJJ <br />LL! <br />Q <br />t^ p Z v <br />Lu a H <br />r-� <br />Q <br />Z <br />ce , Z <br />� <br />Z <br />tj <br />Z <br />` Z <br />0 <br />oo <br />g <br />= <br />Z <br />nr-I <br />d <br />() <br />SCALE : AS NOTED <br />DATE : 12/28/2017 <br />TECH: ERAN D <br />VERSION NO. 10 <br />SHEET NO. <br />4.0 <br />WE - <br />