My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6502 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6502 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:58:15 PM
Creation date
2/19/2025 2:49:28 PM
Metadata
Fields
Template:
Building Plans
Street #
6502
Location
Wagon Trail St
Contractor
Lennar Homes LLC
Building Plans - Permit #
19502
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c <br />zt <br />T-10" 1. 4'-8" 1. 4'-8" <br />3' <br />A <br />H.B+ S3 <br />T-8" <br />T-4„ <br />:.r..�.�.�.�............ �._...�.�.�.�. ce ..�.�.—I— — <br />11. •iO4 <br />�....—:- — ——.............. ........... ....................... ......... <br />, <br />CP <br />\ i I <br />°' <br />3-1/2" MIN 2500 PSI CONC <br />SLAB OVER 6 MIL VISQUEEN <br />VAPOR BARRIER <br />: ■ <br />J <br />(3000 PSI CONC. SLAB FOR <br />HERNANDO COUNTY ONLY) O <br />\\ <br />• \ <br />0'-0" <br />\ \\ I I I i) � 1T0 I <br />r � . . . . . . . ... . . . . . .—.. — — I J I�— <br />f , <br />■ \ \\ 13'-5CO <br />4„ CJ T-2" CJ i 1 CJ <br />I <br />f <br />CJ CJ <br />Ll7 <br />bo <br />\ ' <br />\ 11 <br />I <br />CI) <br />\ co <br />: I I ■ <br />. . . . . . . . . . . . . . . . .. <br />,• I \\'' CY) <br />. . . . . . . . . . . . . . . . . <br />N <br />....................... <br />----------y-------:: <br />A <br />I K (2) #5 REBAR <br />S3 <br />it VERTICALS w/ in <br />I I <br />7 I I ; FILLED CELL <br />it ilk 1 <br />I 23' 11" 2'-10" q, 14„ <br />1 } <br />2'-6" 0.CD <br />i } <br />0 <br />A H.B. T L <br />S3 S3 <br />3'-0" TYP <br />2'4" 5'-2" 5'-1" 64' <br />2'-6" x 2'-6" x 1'-0" <br />W/ (3) #5'S E.W. <br />c <br />FOUNDATION PLAN <br />SCALE: %4'=1'-0" <br />NOTE: <br />• WHERE PROJECT IS TO BE LOCATED IN KNOWN RADON GAS <br />PREVALENT AREAS, APPENDIX "E" OF THE FBC 6th EDITION (2017) <br />BUILDING IS TO BE IMPLEMENTED. CONCRETE STRENGTH IN THESE <br />AREAS TO BE A MINIMUM OF 3000 P.S.I. THEREFORE, ANY AND ALL <br />NOTES ON THESE PLANS THAT INDICATED 2500 P.S.I. SHALL BE <br />REPLACED WITH 3000 P.S.I. FOR THE CONCRETE STRENGTH <br />• SEE SHEET SN FOR SOIL & TERMITE NOTES. BORATE / BORACARE <br />TREATED LUMBER IS AN ALTERNATE TERMITE PROTECTION TO SOIL <br />POISONING <br />W.W.M. PLACED IN <br />1/8" SAWCUT x 1/4 SLAB <br />UPPER 1/3 OF SLAB <br />THICKNESS WHERE <br />OR FIBERMESH <br />SHOWN ON <br />REINF. SEE PLAN. <br />FOUNDATION PLAN <br />W <br />Z <br />J <br />d <br />CONTROL JOINT DETAIL <br />SCALE: 11/2"=1'-0" <br />�•' <br />#5 CONT REINF. SEE <br />.` <br />'�_ <br />FND. FOR QUANTITY <br />•;; <br />��' <br />','��:' <br />;r <br />#5 X 25" X 25" CORNER <br />�' <br />_�•' <br />BAR ONE FOR EA. <br />�'� ' <br />' ' , <br />•. ' <br />• <br />HORIZ. REBAR, TYP. <br />'�. <br />" <br />U.N.O. <br />:. �. :• �• ;�. <br />a,:.: <br />', <br />**Alternate: <br />• <br />The reinf. bars shall be <br />��,: • �r �: • �:=, ;�,; • �r, �:= <br />cont. around corner by cold <br />bending the bar w/ min. <br />bar lap of 25". <br />TYP. CORNER BAR DTL. <br />SCALE: 1 1/2"=V-0" <br />u7 <br />C9 .- <br />Z � <br />— 0 <br />o <br />Z cry <br />Z <br />Q <br />J <br />w <br />�U — <br />O LU <br />E <br />�� C <br />o0 <br />W <br />F--- E <br />0) cM <br />IO -0 - <br />O o N <br />_" <br />o <br />CU <br />U) C <br />Lc> <br /><C 0 <br />O <br />QSQ <br />CN <br />$Y 46 <br />N <br />. <br />�tf OlO <br />C <br />a`A <br />�LI <br />N� `° Cho <br />z <br />W ¢ r�1�:, <br />419 <br />G7 E `l <br />To the best of t in eWi $k, r, and <br />belief, the structur F 'm and spe't,ficatio �iy ned <br />within these drawings cobr�j¢ rida <br />Building Code - Residential 6MUt! ngineer's <br />signature and seal Is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />11 <br />O <br />C) <br />Z <br />0 <br />> (O 00 <br />M <br />Q�f0 Lr) <br />a tn•Ld' <br />H L_L� <br />Q <br />U a '-' <br />Q <br />E <br />Z <br />W <br />J <br />� <br />Z <br />W25 <br />za <br />a <br />FF <br />z <br />LU <br />E.LU <br />LUI.Q, <br />Z V Z Z <br />GL <br />W <br />aaO,n <br />p <br />O0 <br />m rz 0 <br />Ln <br />Z Z <br />O <br />az <br />ZW <br />Z <br />O <br />7 <br />L <br />a <br />v) <br />(� <br />::D <br />0 <br />Z <br />T'I <br />O <br />O <br />U <br />0 <br />a <br />�x <br />z <br />0 <br />o� <br />o <br />i � <br />° � <br />2: 8 <br />28 <br />N <br />Zao¢ <br />Way <br />�aQa <br />0 <br />z <br />w <br />N <br />Ln <br />g o, o <br />jai= <br />+ q <br />w <br />Q <br />W <br />Q <br />z <br />(noZ° <br />z <br />U <br />9az <br />m <br />0 <br />00 <br />gz <br />z <br />f <br />a <br />SCALE : AS NOTED <br />DATE : 12/28/2017 <br />TECH: ERAND <br />VERSION N0. 10 <br />SHEET NO. <br />6.0 <br />