6523 Bar S Bar Trl
Zephyrhills
>
Building Department
>
Building Plans
>
6523 Bar S Bar Trl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:30:03 AM
Creation date
2/19/2025 2:49:05 PM
Metadata
Fields
Template:
Building Plans
Street #
6523
Location
Bar S Bar Trl
Contractor
Lennar Homes LLC
Building Plans - Permit #
5109
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />e14 to lights & outlets <br />NF1AA 1 Y72 M appliances and GFI <br />150 AMP/ <br />200 AMP COMM <br />Range <br />n 1 5o=2ro <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND connect <br />SERVICE BY POWER CO. <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING Q #4GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWERIUTILITY COMPANY. <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance With FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included In the spacing of the outlets unless the distance <br />from the sink or range Is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />IWALL <br />SWITCH <br />�3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />© <br />EXHAUST. FAN <br />1O\ <br />\ ,1 <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />F0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />VERIFY METER <br />LOCATION WITH <br />®2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. BUILDER <br />O THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />EN SINK <br />Aof <br />IBM <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />ELECTRICAL PLAN - ELEV-131 <br />SCALE: Y4'=1'-0" <br />CV <br />C'V <br />O <br />Cn .2 <br />-o <br />a> M <br />a <br />QOtya . D <br />yes r7Cr � <br />fR o„ — <br />Aft -r4; t <br />... t'S', M <br />AV u _,a <br />_ 40 <br />N fl- <br />C <br />@ O <br />ci u <br />0 <br />N <br />N <br />N <br />M <br />To the best of the Engineers kramedge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seat Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />a <br />E <br />ro 8 <br />N <br />.-9 N <br />0 <br />'2 <br />sy LL <br />C J <br />�LLLL <br />LL W <br />a <br />� <br />m c� <br />0 <br />Wa 4 <br />0 <br />L"j to Cl)CNM Z <br />Q' <br />ZW N OU <br />Z <br />z <br />Z <br />�N z <br />4 <br />N <br />"LLJ <br />O W s <br />� c d <br />a <br />S <br />o <br />W <br />Z <br />M <br />E <br />ii � <br />skLL <br />7d <br />zo <br />8 <br />R5 <br />w <br />Z <br />tE <br />E <br />� <br />.0 <br />az <br />rc°j <br />Q3 L <br />wo <br />do <br />mi <br />o <br />� @ <br />� <br />Z <br />Z <br />az <br />ZZ <br />o <br />aQ <br />W <br />3 <br />_� <br />LL <br />4 <br />0 <br />cr co <br />0Z Ww <br />0CD,� <br />UZi <br />120L <br />J <br />L <br />L <br />m <br />C9 <br />Q <br />CL <br />N_ <br />Co MO <br />CM <br />Y <br />� <br />CD <br />''/ <br />v/ <br />Co <br />LO <br />T <br />a� <br />}% <br />N <br />o <br />.0 <br />N <br />Ill") <br />Q <br />Lin <br />r <br />T <br />E <br />.2 N <br />Z <br />c <br />E T <br />c <br />a. <br />U Q p <br />JOB <br />NO : 22-06465 <br />SCALE : AS NOTED <br />SHEET NO. <br />4 <br />