ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />NEMA 1 <br />200 AMP <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />MAIN <br />O <br />2/0 or <br />4/0 SER Alu <br />200 amp <br />ir <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />— 4 Bare Cu Ground <br />#4 GROUNDING WIRE <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />2%52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: <br />unless otherwise noted, <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7, Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />CS. <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />C.M <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />?4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />P.C. <br />e� TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />M <br />OWNER'S S y ITE <br />ROUGH -IN FOR / <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />rr <br />/ <br />I <br />FAMILY RM , <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />1 <br />— _GFI -—_� <br />lO EXHAUST FAN <br />1 _ _ <br />/-_--_-__ <br />EXHAUST FAN/LIGHT COMBINATION <br />�(� <br />PA Q CAFE / <br />_____ <br />F — — <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />I <br />o <br />D.W. <br />CH CHIMES (OPTIONAL) <br />/ <br />INK <br />/DIS <br />C7 PUSHBUTTON SWITCH (OPTIONAL) \ F 1 <br />( PENDANT AS \ <br />SD SMOKE DETECTOR / PER SPECS <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />AC PAD / {GFI • n n • --� TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />qp <br />H.B. <br />T <br />O <br />THERMOSTAT <br />GFI DISC. <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />6� <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />=Iiiiiilons <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H.B. <br />�J IRRIGATION <br />'- VERIFY LOCATION GFI @ 44" A.F.F. <br />W H ELECTRICAL PANEL <br />O I <br />I <br />I <br />I <br />2 CAR GARAGE <br />I <br />I <br />GFI FOR <br />GAR. D04 <br />GFI <br />GFI @ 44" <br />A.F.F. <br />I <br />I <br />_ I <br />I <br />I <br />� / f <br />L------------ <br />GFI @ 44" <br />A.F.F. <br />S.D <br />i <br />I <br />ENTRY <br />I <br />WP j <br />GFI I <br />BEDROOM 4 <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />MAIN FLOOR ELECTRICAL PLANT <br />SCALE: %4"=1'-0" <br />C9 t2 <br />Z Min <br />O <br />-Mal <br />CD <br />Q <br />=j <br />0 <br />�� <br />7' <br />4--j W <br />Q <br />W <br />O r� <br />FE <br />N <br />0 <br />C) <br />�- <br />— 8 <br />M Cl)W C . ch <br />mach <br />C) o N <br />,!p <br />r <br />LLco u.u. <br />or; <br />i sMQo <br />-a <br />a�o <br />Al I <br />H _BID <br />N � co <br />o oo' o co <br />rr�� o N Z <br />/f� � i <br />�Z� r lL. IJL <br />ii (n N w <br />ItIV Q yID N W <br />Wci¢a_=Z <br />Z C rnM <br />CD. <br />LLv N m o n o m m <br />Z � �NB <br />�o <br />LY mac o <br />O U U O� <br />❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />� <br />Z <br />0 cu <br />tZ <br />> Cf) O <br />M <br />V) <br />Q 0 LL Ln <br />sZ r <br />rn <br />00 <br />Q U 0-'-' <br />z E`" <br />W <br />J O�0 <br />oz <br />il <br />Za <br />a <br />z <br />Q <br />Warms <br />�Z80 <br />J <br />ZWa <br />z <br />t��ZZ <br />—w <br />J <br />�8 <br />> aO_no <br />doj <br />*� <br />U <br />um-�o <br />oZw <br />zS <br />ONgZ <br />O <br />g <br />� <br />ro <br />IM <br />W <br />W <br />> <br />C: <br />O <br />U <br />On <br />ro <br />�a <br />�LU <br />O <br />v <br />boo <br />0 <br />- <br />LL_ <br />f Y I" <br />xoc6 <br />z <br />u�md <br />oQoa <br />�k <br />Q <br />c <br />��Q3 <br />Q <br />d" <br />Goo <br />Z <br />N <br />ooa91 <br />W Cy <br />au z <br />J <br />rI <br />di <br />oZU <br />LLI <br />ova <br />W~~ <br />M <br />Q <br />Z <br />it z <br />Ln <br />O <br />Z <br />Z <br />= <br />cyz <br />m <br />O^ <br />� <br />O <br />W <br />Z:Z <br />�o <br />a <br />,- 4 <br />d <br />Ln <br />SCALE : AS NOTED <br />DATE : 1 /4/2018 <br />TECH: ERAN D <br />VERSION N0. 10 <br />SHEET NO. <br />4.0 <br />