My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6614 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6614 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 10:43:45 AM
Creation date
2/19/2025 2:51:07 PM
Metadata
Fields
Template:
Building Plans
Street #
6614
Location
Wagon Trail St
Contractor
Lennar Homes LLC
Building Plans - Permit #
19509
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />1 <br />14 copper to lights & outlets <br />1.- 1 #112 copper to 20 amp cots <br />200 AMP <br />#10-2 copper to WH <br /># 10-3 copper to Dryer <br />�5 ^L <br />2/0 or 4I0 SER Alu <br />200 amp <br />150 amp <br />Disco n Ct <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />------------------------------------------------ <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />RECEPT. <br />FC......... <br />PET -DUPLEX CONVENIENCE OUTLET I p 12 <br />- / IN ATTICJYy <br />�f"'1�;1 ' I - --�-- --I I' = - - l <br />DUPLEX OUTLET ABOVE COUNTER O+ <br />�&wP WEATHERPROOF DUPLEX OUTLET FI I 4- `--J <br />- ROUGH -IN FOR L _ <br />OPT. CLG. FAN/ <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET -� ' I I <br />-- ; ► -- - +- I i � ._ I \ LIGHT PRE -WIRE I <br />10 I i \ I \ <br />HALF -SWITCHED DUPLEX OUTLET I � � I I I \ I <br />SPECIAL PURPOSE OUTLET db <br />I <br />DUPLEX OUTLET IN FLOOR <br />S.D <br />220 VOLT OUTLET }•-�qp <br />r—� <br />WALL SWITCH <br />3 THREE-WAY SWITCH <br />� OWNER'S / _ _/_ � <br />FOUR-WAY SWITCH <br />4 RHEOSTAT SWITCH SUITE / // -- <br />LOFT <br />$R C\ � H I \\ <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE G �' -- <br />ROUGH-IN FOR I <br />O RECESSED LIGHT FIXTURE OPT. CLG. FAN/ - --- I I ROUGH -IN FOR <br />LIGHT PRE -WIRE,,,, - --- I OPT. CLG. FAN/ <br />LIGHT FIXTURE WITH PULL CHAIN / I LIGHT PRE -WIRE <br />1 2 -*-7 <br />TRACK LIGHT I I 11 T I I ` <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />F1 <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />mpg <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />C Im J <br />OPT. CEILING FAN <br />69 <br />(1) PHONE LINE, (1) DATA PORT <br />UPPER ELECTRICAL PLAN <br />SCALE: %4"=V-0" <br />® <br />� <br />CD <br />Z M <br />_ p4 <br />N <br />z QQQ <br />Q <br />Ln <br />W cn <br />w <br />O L <br />m <br />V <br />w <br />d) M <br />m M <br />N --0 M <br />4/..,... �. �. <br />U <br />.0 t.L pp <br />� oO <br />01a <br />m rn <br />o N <br />o oNo <br />Z <br />Z W <br />Z <br />a�N oW <br />a <br />0- <br />O Z < <br />�sY <br />LL� mEop <br />o <br />m m <br />Z ° < <br />W N <br />Na�j� <br />Jqo[] <br />� O <br />❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal Is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />0 <br />Z cV <br />0 n <br />f>- CD <br />M <br />Q LI) 'gyp � <br />n <br />0 <br />Q — Ln <br />Q �. <br />UE <br />Vfu <br />a00 <br />Q <br />ZZ <br />ru <br />W <br />J � <br />d' <br />J <br />�z <br />333'y <br />0 <br />Z a <br />Ea <br />N <br />< <br />U?°o <br />t�szz <br />___I <br />00 Z, <br />Q <br />_U© <br />0 <br />L r) <br />U <br />Z <br />Z <br />-a <br />N <br />LJJ <br />4 <br />W <br />o <br />N <br />a <br />U <br />U) <br />J <br />r-o <br />OJ IlD <br />z <br />u <br />fV <br />Q <br />= � <br />��za <br />Q <br />�$IdX <br />Z <br />cV <br />N <br />a <br />w CY <br />a�orZ <br />J <br />r-1 <br />11.1 <br />Q <br />� <br />Z <br />o Z UV <br />g <br />M <br />k <br />Ln <br />Z <br />a <br />m <br />00 <br />� <br />2 <br />`� <br />,-i <br />a <br />V) <br />SCALE : AS NOTED <br />DATE : 1 /5/2018 <br />TECH: MJAM ES <br />VERSION NO. 10 <br />SHEET NO. <br />4.1 <br />