Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />WALL SHEATHING <br />t 1--..t .......... . <br />\.:::I :::::::::::: :�� :.::.::::: <br />11` k I <br />16GAx1-1\2" LONG 3/4"-1" CROWN 8' .........::: <br />( ) MAX ...........L .�........................ . <br />STAPLES @ 6" O.C. VERT BETWEEN I 16GAx1-1/2" LONG (3/4"-1" <br />STUDS (NOTED THUS:—) - OFFSET CROWN) STAPLES @ 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE 0 0 O <br />5'-0" Q — <br />STUB -OUT FOR 1'-0" o 0 - <br />LO <br />GAS METER 0 o <br />U <br />O <br />N O <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7-5" <br />(2) 16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-Y <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2) 16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2) 16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2) 16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3!4" or 7i8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 112" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />FILL CELLS STD. 90° HOOK BOND BEAM <br />SIMPSON MGT <br />w/(22)10d <br />W NAILS TYP. GIRDER TRUSS <br />Cr <br />j STD. 90° CONT. #5 <br />BI HOOK (�BAR r 2X TOP PLATE <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. <br />2" <br />} Small gap 2" min. <br />max. 4 max. <br />p <br />Clinch nails <br />when <br />possible 1 <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 2x4/Plywood/OSB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails required when indicated or 4" max. <br />2x : CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />DOUBLE JOIST CONNECTION top flange <br />uthcutst. <br />- Birdsmouth cuts. N.T.S. <br />Under 2nd floor whimn w/ Inaris <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />1/16 <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />1 or=20 sinker <br />lateral load. <br />T nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls <br />higher than 15001b <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series De th End Intermediate <br />0 <br />BCI5000SR <br />9-1/2" <br />; 2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5 d <br />BCI 6000s® <br />BCI 6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60e <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI 90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />16" <br />6-16d <br />6-16d <br />5/81 <br />THRU <br />BOLT <br />I.0 <br />SIMPSC <br />w/(22) <br />NAILS 1 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />Provide adequate bearing <br />for each lapped joist. Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />Od nails require additional consideration. <br />SECTION @INT. BRG. WALL— <br />( N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />6„ A ROUND HOLE MAY 6„ 6„ DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1%" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2" <br />8 <br />1-t3" <br />I 1'-' ' <br />T <br />'I'-Z' <br />t" S" <br />1'-3 <br />1 -7" <br />1'-11 " <br />2-4" <br />2 <br />32' <br />S' 7" <br />Any 16"joist <br />12 <br />I,_a, <br />1'-1' <br />112 <br />12z' <br />1, 3'" <br />1191 <br />2-4' <br />2-11" <br />3 7" <br />4' 2' <br />�#'�° <br />9-4' <br />-- SF��)_ <br />1 <br />1,-U" <br />1'_1" <br />1'2' <br />1 2" <br />1 7'" <br />3` 2' <br />3'-10" <br />4'9" <br />677 <br />'-4' <br />7 2• <br />20 <br />1' Q ° <br />1'-1" <br />1' 2" <br />1' 2" <br />-U' <br />3-9' <br />4'-a' <br />4'-10 " <br />6-11" <br />C'-11'" <br />7 A T' <br />El 1-" <br />_______­___24 <br />.____----- _ - <br />24 <br />1'-0 <br />1'-1" <br />1' 2 <br />1'-3'" <br />2'�a" <br />3-7" <br />4'-9 <br />5'-1t?'• <br />7" 2" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y2" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3' to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />_WIN , <br />1111� <br />Backer block (12" wide min.) -i 11=1 I 1=1 I 1=1 11— —I I I <br />Nail with 10-10d nails. '=1 11=i 11=1 I I —I I I% <br />Install tight to top flange. SLEEVE THRU STEM J <br />s a.. <br />Joist hanger SEE PLAN FOR °• Q . • • <br />FOUNDATION INFO ` 9 <br />All <br />STEM FOUNDATION <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />I <br />0.6 X Joist <br />" depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />4 <br />�—REINF. SEE PLAN <br />(2) #5 REBAR <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />SIMPSON H10A <br />w/ (18)10d x 1 1/2" ° <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4' 0" <br />CENTERED @ PIPE <br />PENETRATION <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />(WHEN <br />REQUIRED) <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />d <br />a Q <br />d: a <br />° —III- I 1—, <br />-L-- SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />a <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />q <br />° f-r-r d _ <br />z • a � .. <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />G d <br />°V. d .dG G <br />-I I El I IE1 a ® ° I -I I f 11 I- <br />''1I— <br />SEE FND. PLN. <br />SIZE & REINF. <br />N � O <br />CP <br />.0 <br />t to <br />d <br />c;, <br />r <br />Y. <br />L� � <br />CV <br />CV <br />0 <br />CV <br />M <br />0 <br />M <br />0 <br />r j <br />r. ;i <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Honda Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />C. <br />iW- <br />Q <br />of <br />O -4 N iY <br />0 <br />11 <br />'� u7. W N �t LL W <br />M <br />U) <br />Q <br />rn��� LL W a <br />N o a — <br />Ju_u_ ay <br />0 <br />CIL <br />Y <br />Z <br />— � <br />0 <br />s@ 0 0 W <br />�N X O J <br />W <br />nY) m¢ G <br />�` <br />o <br />N co z W v) O <br />Z <br />O U U <br />W <br />❑�0 <br />( M <br />z C o0 <br />� N <br />z � � <br />J — <br />r <br />V) <br />eNi <br />z <br />U = <br />cl: <br />� <br />0 <br />+� <br />f(j <br />rl, <br />(D <br />O <br />N <br />Ln <br />= <br />�N <br />= y <br />wigw <br />J <br />'— — E <br />- r 8 <br />I <br />t <br />U o <br />° <br />N - <br />III <br />M <br />W <br />M�Q <br />M <br />o <br />Z <br />J <br />U_ <br />O <br />E <br />E <br />� <br />z ❑ <br />O <br />Zo <br />¢ N <br />z© <br />F— <br />z� <br />U❑ <br />ab <br />_° <br />oQ <br />[= E <br />N � <br />L <br />p <br />wo <br />p <br />a Z <br />ttw <br />i <br />x0 <br />'0 <br />Ott <br />Z <br />Z <br />m <br />Q W <br />�Z <br />w <br />zo <br />22 3 <br />O Q <br />LL <br />U <br />a <br />ww <br />W <br />3 <br />w <br />o <br />J= <br />w� <br />=3 <br />�� <br />;o <br />J <br />co <br />v <br />M <br />d H <br />°3 <br />LO <br />N <br />rn <br />N <br />cc <br />/^\ <br />CID <br />J O <br />O <br />Cr <br />O <br />Y <br />CD <br />MS <br />W <br />+-+ <br />T <br />O <br />N <br />Q1 <br />::0 <br />N <br />c� <br />L O <br />r <br />Q <br />M <br />T <br />E <br />= M <br />o <br />z <br />m <br />z <br />v <br />E Oc <br />a. <br />U J <br />76 <br />Q � <br />J <br />JOB <br />NO: <br />22-02395 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />