Laserfiche WebLink
SIMPSON HGAMV <br />W/ <br />(4) 1/4"x1 1/2" SDS <br />SCREWS <br />TO BLOCKING & (i <br />1/4"X2 3/4" <br />TITEN TO CMU <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2) 16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING AND <br />FASTENERS. (MIN. FIRST 4 BAYS) <br />SEE STRUCTURAL NOTES AND NAILING TOENAIL w/ <br />SCHEDULE FOR SHEATHING DETAIL-7 (2) 16d NAILS--\ <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />MAX.9" AND FASTENERS. (MIN. FIRST 4 BAYS) <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 BACKNAIL w/ (2)16d NAILS —� <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />MAX. 9" SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />UNSUPPORTED, AND FASTENERS. (MIN. FIRST 4 BAYS) <br />IF >9" SEE 10/S5 <br />BACKNAIL w/ (2)16d NAILS <br />SEE STRUCTURAL NOTES AND NAILING <br />SCHEDULE FOR SHEATHING DETAIL \ <br />' <br />45°± <br />/ <br />45° ± <br />SEE STRUCTURAL <br />NOTES AND NAILING <br />2x4 CRO <br />BRACE <br />SCHEDULE FOR <br />APPROX. 8" FROM <br />SHEATHING DETAIL <br />2x4 KICKER <br />2x8 SYP#2 "L" BRACE TO <br />RIDGE FASTENED AT <br />@ 8'-0" O/C. <br />EXTEND AT LEAST 90% OF <br />EACH JOINT W/ (3) 1 Od <br />"L" BRACE TO EXTEND <br />2x4 CROSS BRACE <br />WEB LENGTH &NOTCH AT <br />& (2)10d TOE NAILS @ <br />AT LEAST 90% OF WEB <br />APPROX. 8" FROM <br />BOTTOM CHORD (SEE TABLE) <br />EA. END @ 48" O.C. <br />'• <br />LENGTH (SEE TABLE) <br />RIDGE FASTENED AT <br />SIMPSON H2.5A w/ (10) 8d <br />2x8 P.T. <br />GABLE TRUSS <br />EACH JOINT w/ (3)1 Od & <br />FROM LEDGER TO <br />• <br />SILL <br />1/2" CDX PLYWOOD OR <br />(2)10d TOE NAILS @ EA. <br />BLOCKING <br />7/16" OSB SHEATHING <br />END <br />GYPSUM WALL BOARD <br />ATTACHED W/ 10d <br />GABLE TRUSS <br />NAILS @ 6" O.C. EDGES <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />1/2" CDX PLYWOOD OR 7/16" <br />AND 12" O.C. FIELD <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />OSB SHEATHING ATTACHED <br />10dX3" @ 3" O/C <br />CORD ATTACHED W/ (2)16d TOENAILS <br />w! 10d NAILS @ 6" O.C. <br />THROUGH CHORD <br />2"x4" LEDGER (MATCH BOTTOM CHORD <br />EDGES AND 12" O.C. FIELD <br />LU <br />INTO 2" 6" P T PLATE <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />AND FASTENERS. (MIN. FIRST 4 BAYS) <br />MAX. 9" <br />UNSUPPORTED, BACKNAIL w/ (2)16d NAILS MAX 9 <br />IF >9" SEE 10/S5 SEE STRUCTURAL NOTES AND UNSUPPORTED, <br />G) DETAIL <br />SCHEDULE FOR SHEATHING IF >9" SEE 1O/S5 <br />DOUBLE TOP PLATE <br />2"x4" CROSS BRACE <br />2x4 CROSS BRACE APPROX. 8" <br />APPROX. 8" FROM <br />FROM RIDGE FASTENED AT <br />RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />EACH JOINT w/ (3) 10d & (2) 10d <br />EACH JOINT w/ (3) <br />AT LEAST 90% OF WEB <br />TOE NAILS @ EA. END <br />10d & (2) 10d TOE <br />LENGTH (SEE TABLE) <br />2x FRAME WALL (SEE WALL <br />NAILS @ EA. END <br />GABLE TRUSS <br />SECTION FOR SIZE & SPACING) <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR <br />1/2"CDX PLYWOOD OR 7/16" <br />@ 48" O/C FOR THE <br />(2) 16d <br />7/16" OSB SHEATHING <br />OSB SHEATHING ATTACHED <br />FIRST 4 ROWS OF <br />() <br />NAILS <br />ATTACHED w/ 10d NAILS <br />W/ 10d NAILS @ 6" O.C. EDGES <br />TRUSSES FROM EA. <br />@ 6" O.C. EDGES AND 12" <br />• <br />AND 12" O.C. FIELD <br />END TYP. TOP & <br />O.C. FIELD <br />BOTTOM ATTACHED <br />(2) 16d NAILS <br />W/ (2)16d TOENAILS <br />2x4 "T" ON TOP OF PANEL <br />X 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING BLOCKING, FASTEN WITH <br />2x4 "T" ON TOP OF PANEL BLOCKING, 2"x6" P.T. SILL NOTCH "L" BRACE HERE <br />FASTEN WITH 1 Odx3" 4" O/C SPACED WEEP SCREED -- THE FIRST (4) ROWS OF TRUSSES 2x4 "T" ON TOP OF PANEL 10dx3" @ 4" O/C <br />@ 1/2 x 8 J BOLT 48 O.C. <br />@ 48" O.C. INSTALLED PER MANUF. @ WEEP SCREED FROM EA. END TYP. TOP &BOTTOM BLOCKING, FASTEN WITH SIMPSON HGAIOKT w/ (4)1/4"x1 1/2" SDS SCREWS TO <br />MOISTURE BARRIER SIMPSON META12 w/ (7)10dx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2)16d TOENAILS l BLOCKING, <br />Odx3IN 4" FA TRUSS & (4)1/4"x3" SDS SCREWS TO PLATES AT 24" O.C. <br />1/2 x 8 J BOLT @ 32 O.C. MINIMUM 6 FROM <br />O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />MOISTURE BARRIER <br />PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER <br />SIMPSON META12 w/ (7) <br />ALTERNATE SIMPSON MSTAM24 w/ (7) 10d NAILS <br />NOTE: IF EMBEDDED <br />1Odx1 1/2" NAILS AT EA. <br />& (4) 1/4"x21/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL <br />SECTION <br />rT� TRUSS VERTICAL WEB (24" <br />GABLE WEB SECTION- 2 <br />WEB, USE MSTAM36 w/ (7) <br />O.C. MAX) w/ MIN. 4" <br />10d NAILS & (4) 1/4"x21/4" <br />SCALE: N.T.S. <br />S5 EMBEDMENT IN KO BLOCK <br />SCALE: N.T.S. 55 <br />TITEN ON OUTSIDE <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />REFER TO DETAIL J <br />N <br />N <br />AND FASTENERS. (MIN. FIRST 4 BAYS) <br />ON SHEET S5 FOR <br />'- <br />X-BRACING, AND TOP <br />° <br />SEE STRUCTURAL <br />CHORD BLOCKING <br />N <br />- <br />NOTES AND NAILING <br />INFORMATION <br />SCHEDULE FOR <br />SHEATHING DETAIL <br />BACKNAIL w! <br />WOOD TRUSSES <br />`° <br />00 <br />1 1 <br />00 <br />1/ <br />2"x4" CROSS BRACE <br />(2) 16d NAILS <br />APPROX. 8" FROM <br />N <br />2x4 RAT RUN BRACING <br />RIDGE FASTENED AT <br />AT 24" O.C. TOP OF <br />U <br />EACH JOINT w/ (3) <br />BOTT. CHORD FOR 4 <br />10d & (2) 10d TOE <br />TRUSS SPANS <br />ATTACHED W/ 2 -16d <br />NAILS @ EA. END <br />AT EA. TRUSS JOINT <br />2 2" x 4" LAMINATIONS W/ 1 ROW <br />() () <br />(3) 2" x 4" LAMINATIONS W/ 1 ROW " <br />() (3) 2 x 6' LAMINATIONS W/ (2) ROWS OF <br />2x4 PANEL BLOCKING <br />F STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30dCOMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS <br />@ 48" O/C FOR THE <br />• (2)16d NAILS <br />2x4 BLOCKING 24" <br />@ <br />D = 0.148 , L = 3") OR EQUAL <br />O <br />(D = 0.207", L = 41/2" OR EQUAL (D = 0.207", L = 41l2") OR EQUAL <br />FIRST (4) ROWS OF <br />O/C W/ (2)16d <br />TRUSSES FROM EA. <br />TOENAILS @ EA. END <br />NOTES: <br />END TYP. TOP & <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 5 1/2" LAG SCREWS OR EQUAL <br />BOTTOM ATTACHED <br />MASONRY WALL <br />OF THE COLUMN <br />(SPACE AS SHOWN FOR 3-PLY) <br />w/ (2)16d TOENAILS <br />ARCHITECTURAL FINISH <br />2) ALL NAILS PENETRATE AT LEAST 314 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL <br />OF THE LAST LAMINATION <br />(SPACE AS SHOWN FOR 3-PLY) <br />2x4 BLOCKING 2x4 "T" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />1 Od NAILS @ 4"- i <br />O.C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 "T" BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ 10d NAILS @ 4" O.C�FAA <br />TYPICAL <br />GABLE TRUSS WEB <br />SINGLE "L" BRACING DETAIL 6 <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" 0/C GABLE TRUSS <br />TRUSS VERTICAL <br />SIMPSON SP2 w/ (12) 1 Od <br />2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE NAILS AT EACH STUD (2) 2"x8" "L" BRACE <br />SLOPE OF ADJACENT TRUSS) STUD WALL (SEE TYP. SEC.) FASTENED WITH (3) <br />16d PER SIDE <br />SECTION 3 SECTION 4 SCISSOR GABLE "T" BRACE 7 <br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 AS PER HIB 91 SCALE: N.T.S. S5 <br />MAX. 9" <br />UNSUPPORTED, 8d @ 6"0/C <br />IF >9" SEE 10/S5 r-WOOD TRUSSES <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR 7/16" <br />OSB SHEATHING ATTACHED <br />W/ 1Od NAILS @ 6" O.C. <br />SIMPSON HGAMI OKTA w/ (4) <br />E ES AND 12" O.C. FIELD <br />1/4"x1 1/2" SDS SCREWS TO <br />JACK TRUSS <br />BLOCKING & (4) 1/4"X2 3/4" <br />SEE PLAN FOR <br />TITEN TO CMU <br />CONNECTION <br />2x4 "T" ON TOP OF PANEL I L <br />EXT. WALL CONN. 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION BLOCKING, <br />4" 0/CTEN WITH L �2� 12dOT0ENAI SCKING / <br />NON -LOAD BEARING LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF <br />D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) SECTION <br />SEE TYP. WALL SECTION FOR SCALE:3/4"=1'-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 9 <br />ADDITIONAL INFORMATION, SCALE: N.T.S. S5 SCALE: N.T.S. 55 <br />4INIMUM 2x <br />'ROSS BRACING <br />SEE PLAN FOR <br />OCATIONS) TOENAIL <br />(2)16d NA <br />(2) 16d PER <br />JOINT <br />t-- CONTINUOUS BOTTOM CORD BRACING 2"x4" MrT� <br />IN..SEEM/S5 <br />CROSS BRACING DETAIL <br />SCALE: N.T.S. <br />12" <br />SEE RSH SCHEDULE <br />FOR ATTACHMENT <br />2X4 #2 SYP BLK'G @ 16" O.C. <br />(2) 1 Od x 0.131" <br />TOENAILS EA. SIDE <br />CONT. 2X4 #2 SYP w/ 1 Od <br />XO.131" @ 8" O.C. <br />ALTERNATE NON -DROP <br />GABLE END DETAIL (*�l0 <br />SCALE: N.T.S. S5 <br />GABLE TRUSS <br />S5 <br />"L" BRACE W/ 10d @ 4" O.C. <br />12 (SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />6.9 MAX. <br />S5 <br />S5 <br />CONT. BEARING <br />GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. <br />PRE-ENGINEERED <br />WOOD TRUSSES <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES <br />MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL <br />SCALE: N.T.S. <br />6" OVERLAP <br />M <br />S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />2 x 4 BLOCKING w/ (2)10d <br />TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />0 <br />z <br />w <br />\_BRACING w/ (3)10d x 3" AT <br />EACH CONN. @ 24" O/C <br />\-MOISTURE BARRIER <br />-BOND BEAM <br />- MASONRY WALL <br />ARCHITECTURAL FINISH <br />EXT. WALL CONN. @ NON - LOAD <br />BEARING LOCATION (UNEVEN CLG.) <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />"L" BRACING REQUIREMENTS <br />STUD <br />SPACING <br />NO <br />"L" BRACE <br />(1) 2"x4" (U.N.O.) <br />"L" BRACE <br />2"x6" (U.N.O.) <br />"L" BRACE <br />24" <br />0'0" - T-0" <br />T-O" - 6'-0" <br />6'-0" & GREATER <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGA10KT w/ (4) 1/4"x1 1/2" SDS-- ^ <br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SIMNSUN 51`2 W/ (12) <br />10d NAILS AT EACH <br />STUD <br />END JACK <br />1 V-0" MAX. <br />Q <br />9 <br />CORNERJACK <br />U <br />w <br />z <br />t1 <br />O <br />U <br />HIP FRAMING REFERENCE PLAN <br />20'-0" MAX 20'-0" MAX <br />"X" BRACE SEE DET. JlS5 CONTINUOUS BOTTO CHORD BRACING 2X4 MIN. <br />'0 <br />NOTE: ZTOP CHORD 2x4 #2 SYP BRACING <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />@ 16" O.C. MAX. FOR FIRST (4) <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />BAYS <br />THAT MY BE REQUIREDZ <br />BOTTOM CHORD GABLE END BRACING <br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT <br />@ 4'-0" O.C. MAX. FOR FIRST (4) BAYS <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />rL <br />AS PER BCSI <br />SCISSOR TRUSS <br />SCISSOR TRUSS <br />_W/ DROP CEILING BRACING DETAIL <br />SCALE: N.T.S. <br />2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />FIXED LOCATION ATTACHED W/ (2) 1 Od AT <br />EA. TRUSS (NOTE: BRACING MAY BE <br />PLACED ON EITHER TOP OR BOTTOM OF <br />THE BOTTOM CORD) <br />COSMETIC DROP CEILING FRAMING <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />N J <br />. O <br />cg ►:41) <br />'74 <br />cz <br />A <br />_ <br />CV <br />CV <br />0 <br />CV <br />M <br />N <br />N <br />0 <br />4c , <br />s <br />'� <br />=�r <br />_ <br />s <br />`3- <br />To the best of the Engineer's knowledge, information and belief, <br />the structural <br />plans and specifications contained <br />within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />W <br />n <br />�Wp <br />'IT E <br />O <br />�5 <br />N <br />N <br />N <br />000 <br />J <br />LL <br />/' <br />G <br />y m <br />in� N <br />J <br />#'� W <br />M <br />a <br />F0 <br />rA�n� <br />M <br />W a <br />a Seui <br />� <br />v> <br />a <br />_�� <br />Ow O <br />Y <br />E <br />L (O p <br />? '� N CD <br />O O W <br />CY 0 J <br />IIi <br />W <br />m <br />¢ -, <br />Z <br />00 0 <br />a <br />N M Z <br />O U <br />W N O <br />U N <br />Z <br />W <br />U <br />N ] <br />o� <br />z <br />Z � <br />Q <br />J - <br />d � <br />r <br />V) <br />cNi <br />z a <br />^' <br />(D <br />U `o <br />+- <br />N LL <br />�O <br />v I <br />w o <br />(may N <br />0 <br />ru <br />U <br />LJ J J <br />z <br />U <br />N Oco <br />IIII� <br />c <br />w <br />co <br />oZ <br />Z <br />CEE <br />o <br />oo <br />w. <br />as <br />O= <br />co <br />W© <br />t- B <br />R O <br />a <br />�U <br />0 <br />O� <br />CV <br />Q� <br />o <br />-z <br />¢ <br />= <br />o U <br />'o <br />o� <br />Z <br />Z <br />�z <br />2C <br />Zo <br />-U <br />SZ <br />LL <br />a <br />�F <br />W <br />� <br />w <br />�M <br />J <br />C:) <br />o <br />W <br />0Ia <br />a= <br />° 3 <br />LO <br />1 ^ <br />12 <br />co <br />L <br />j O <br />co <br />V J o <br />(� <br />M <br />• • <br />m <br />¢I <br />a-�+ <br />N <br />p <br />O <br />N <br />M <br />r <br />04 <br />r <br />N <br />E <br />c co <br />Z <br />z <br />E <br />c;s <br />a <br />E <br />U _j <br />Q p <br />c <br />JOB <br />NO : <br />22-02395 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S5 <br />