My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6629 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6629 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 3:29:01 PM
Creation date
2/19/2025 2:52:11 PM
Metadata
Fields
Template:
Building Plans
Street #
6629
Location
Wagaon Trail St
Contractor
Lennar Homes LLC
Building Plans - Permit #
19599
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WEATHER <br />7 RESISITIVE <br />BARRIER <br />TAPE <br />(ASSEMBLED WINDOW) <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weat <br />THESE DETAILS ARE GENERIC AND barrier above header to allow for flashing <br />installation <br />MEANT TO SHOW GENERAL FLASHING 2. Self adhered flashing plus head flashing under <br />AND WATERPROOFING METHODS TO weather resistive barrier <br />BE USED. 3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />WE <br />✓E BARRIER & <br />?ARILY SECURE <br />EXTERIOR <br />SHEATHING <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHIN <br />BY LAPPING DOWN ------ <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOI; <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />E� <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />i1- SELF -ADHERED FLASHING <br />SUBFLOOR <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />f��i1lL�li.� <br />EXTERIOR SHEATHING <br />EXTERIOR SHEATHING <br />-� <br />314"-1" BEAD OF CONSTR. <br />INSTALL SELF -ADHERED <br />ADHESIVE TO BE APPLIED UNDER <br />FLASHING JAMB & HEAD <br />THRESHOLD OF DOOR AND RETURN <br />FLASHING, SEE <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />FLANGED WINDOW <br />OR EQUAL WEATHER PROOF CAULKING <br />(SEE DETAIL WP01) <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />SELF -ADHERED FLASHING <br />NAILING FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />E <br />AM <br />rr✓rionuv� I �ryal ulv.a <br />Q <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />Eon <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />4 <br />I5 <br />2 <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0.6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />WIRE LATH <br />Q <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />NEEDED IN CORNERS /� RUBBERIZED ADHESIVE <br />THROUGH SELF -ADHERED // ASPHALT ADHESIVE <br />FLASHING -7 SELF -ADHERED FLASHING <br />SCORED <br />RELEASE PAPER <br />(BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />a <br />0 <br />ON <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />�Ground <br />7 <br />SELF -ADHERED FLASHING SELF -ADHERED FLASHING FOUNDATION WEEP SCREED <br />DECK JOIST ' ' OUTSIDE CORNER ' <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />FLASHING REQUIREMENTS <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as in each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />00000or ZZ <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />NOT USED NOT USED NOT USED SCALE: NOT TO SCALE ins am <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede orsim. <br />caulk for all <br />zm <br />0 <br />(D <br />z� <br /><C <br />C) <br />�LU <br />p <br />OL' <br />Ln Z:) <br />E <br />Cn <br />o 0 <br />V <br />N co <br />W <br />q - 8 <br />C (6 M <br />o 2 o <br />_ <br />U- co <br />co <br />ai <br />O y � <br />�o <br />Q rn <br />Lo0 <br />a a o <br />® <br />N C <br />c0 <br />c=> <br />N <br />N <br />co <br />u-5 <br />o v z rn <br />NL-t-Z <br />o <br />ZF9,Mm� <br />l.L <br />A/ LL N <br />W m <br />N m N <br />W <br />itLU <br />LL <br />10 'Z Oa m '5 <br />Q- <br />rn <br />o �¢ <br />U1 9 oho <br />o 0 <br />m m <br />W Q m Q N <br />r .0 <br />J O <br />� O <br />El <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0! <br />0 <br />0 <br />Z r%J <br />O i\ <br />0 <br />.2 o <br />Z <br />I/ -I M O <br />M <br />Q -0 <br />a- to L d- <br />0 rl�- <br />ZZ <br />LL <br />CL <br />" a00 <br />a 00 <br />E <br />§ <br />W O <br />W <br />�C1 <br />d' <br />o� <br />W� <br />za <br />� <br />G <br />Lu < <br />oo8o <br />zi,wQ <br />I-�z Z <br />��z- <br />) <br />LaOu� <br />O LL <br />J <br />u N <br />Q <br />W <br />o� <br />Z Z <br />o y <br />rl <br />W <br />0 <br />zZ <br />s <br />O <br />0 <br />O <br />�W <br />V <br />w <br />Z: <br />o <br />oz <br />�Y0 <br />- <br />O <br />1�2 <br />1-- <br />a <br />X O cg <br />¢ <br />UOa'm2 <br />a <br />fV <br />o. a <br />Zao¢ <br />A <br />1 ` <br />W J <br />CWJQZ< <br />Q <br />$��m <br />Z <br />N <br />W�LLiL <br />Z <br />a <br />a-o�Z <br />J <br />rl <br />LLJ <br />�C <br />„ o Z o <br />E Q <br />t'V <br />Q <br />ZLu <br />oo <br />Ln <br />Z <br />tu <br />=Z <br />a <br />m <br />� <br />J Z <br />a Z <br />06 <br />= <br />r-•t <br />a <br />LO <br />SCALE : AS NOTED <br />DATE : 12/28/2017 <br />TECH: ERAND <br />VERSION NO. 10 <br />0 <br />SHEET NO. <br />WP <br />