Laserfiche WebLink
ROOF FLASHING AND ROOF FLASHING <br />COMPONENTS TO BE IN ACCORDANCE <br />w/ R903.2, FLORIDA BUILDING CODE <br />7TH EDITION (2020) RESIDENTIAL <br />12 <br />:-Z'_7 <br />INSULATION — <br />BAFFLE <br />INSULATION PER - <br />CHART ON FLOOR <br />PLAN <br />5/8" OR 1/2" HIGH STRENGTH CEILING <br />BOARD PER CODE W/ 1 3/8" DRYWALL <br />NAILS OR DRYWALL SCREWS 7" 0/C <br />CEILING & 8" O/C WALLS / <br />1/2" GYP WB <br />DOUBLE 2x S.P.F. TOP PLATE - ATTACH 2x STUDS <br />TO TOP PLATE w/ (1) SIMPSON SP2 TYP. @ <br />CORNERS, SP2 MAY BE SUBSTITUTED w/ (1) H2.5A <br />2X BLOCKING @ EA. WALL <br />SHEATHING JOINT <br />16" O.C. 2X S.P.F. STUDS <br />2x BOT. PLATE W/ (2) 10d @ 6" O.C. <br />3/4" PLYWOOD DECKING GLUED AND NAILED W/ 10d <br />COMMON @ 6" O/C EDGES AND 12" O.C. FIELD <br />1/2" GYP. WB OR 3/8" PLYWOOD/ TYPE 2-M-W OSB <br />(DRAFTSTOPPING) TO BE NAILED W/8d COMMON @ 6" O/C <br />TO ONE SIDE OF THE FLOOR TRUSS FOR AN AREA 5 1000 <br />SQ. FT. OF FLOOR AREA & SEALED PENATRATION AREA W/ <br />FOAM. DRAFTSTOPPING SHALL DIVIDE THE CONCEALE <br />SPACE INTO APPROX. EQUAL AREAS. <br />FLOOR SYSTEM <br />ER PLAN <br />1/2" HIGH STRENGTH OR 5/8" GYP WB (OR 5/8" — <br />GYP. TYPE " X" @ GARAGE ONLY) W/ 1 3/8" <br />DRYWALL NAILS OR DRYWALL SCREWS 7" O/C <br />CEILING & 8' O/C WALLS <br />1/2" GYP WB <br />INSTALLATION PER <br />CHART ON FLOOR PLAN <br />NOTE: LAP SHEATHING TO BOTTOM OF <br />BAND JOIST TYPICAL <br />FOR UNDERLAYMENT <br />REQUIREMENTS SEE R905.1.1 <br />�-PRE ENGINEERED WOOD TRUSS @ 24" O.C. MAX. <br />HURRICANE ANCHOR @ EACH TRUSS <br />SHINGLE ROOF, SHINGLES TO BE IN <br />ACCORDANCE w/ ASTM D7158-CLASS G or <br />H, or ASTM D3161-CLASS F, IN <br />ACCORDANCE w/ TABLE R905.2.6.1, <br />FLORIDA BUILDING CODE 7TH EDITION <br />(2020) RESIDENTIAL <br />ROOF SHEATHING - SEE <br />SCHEDULE - [RSH] - ON <br />FRAMING SHEET FOR <br />SHEATHING AND FASTENERS <br />ALUMINUM DRIP EDGE <br />ALUMINUM FASCIA <br />2x SUB FASCIA <br />SEE STRUCTURAL SOFFIT SHEET SS <br />ATTACHED WALL SHEATHING TO <br />(2) TOP PLATE W/ 8d @ 4" <br />O.C., 2 ROWS <br />1x2 NAILER <br />w PLYWOOD SHEATHING <br />NAILED PER NAILING SCHEDULE SEE DETAIL C/S6 <br />FOR MORE INFO <br />LU <br />o = 7/8" CEMENTITIOUS FINISH PER ASTM C. 926 <br />APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER <br />� METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD <br />� '`i- LAYER 1/8" THICK. <br />Uj <br />U_ L11 <br />—INSULATION PER <br />CHART ON FLOOR PLAN <br />B R <br />S6 S6 <br />ETAL SEAT <br />OR FELT <br />PAPER FOR <br />MOISTURE <br />BARRIER <br />STD. 90 HOOK (SEE DETAIL) <br />8"x8"X16" CONC. KNOCKOUT <br />BLK. W/1#5 ROD CONT. FILLED <br />SOLID W/GROUT <br />-ARCHITECTURAL <br />FINISH <br />(1) #5 VERT. IN FILL CELLS (SEE <br />FOUNDATION PLAN & NOTES) <br />Cl) <br />v 4"x4" INSPECTION PORT AT <br />a EACH FILL CELL TYPICAL <br />Uj <br />1x WD FURRING @ 24" O.C. a AT GARAGE CONTRACTOR <br />BASEBOARD N TO CUT BLOCK OR POUR <br />MIN. 2500 PSI CONC. SLAB CURB DUE TO SLOPE <br />MIN. PSI MAY VARY PER NOTE: EXTEND DECO FINISH <br />MUNICIPALITY 4"to 6" BELOW GRADE <br />..4 <br />iv ° < . AO FINISH GRADE <br />.° 1 <br />Ir <br />'I 1—III—III—III III _ _ <br />6x6 w1.4xw1.4 I I I .I 11=III=I I ICI I I n' °a I=I I=� I=� <br />WWFORFIBERMESH III�IIIII�IIIIII ° IIIIII��I111111= <br />a.° <br />(3) # 5 REBAR ON 3" CHAIR _I 1 I (, I=-1 Ti STD. 90 *HOOK <br />ll <br />(SEE DETAIL) <br />W/3" MIN. CLEARANCE 4" 1'-8" <br />TYP 2-STORY WALL SECTION <br />REV. 03.16.21 <br />SCALE: 3/4"=1'-0" <br />SIMPSON LSTA24 STRAP w/ (8) 10d x 1 1/2" NAILS TO <br />2nd FLO <br />BEAM/GI <br />2ND FLOOR FRAME CONNECTION <br />SEEJ/S-6 FOR ADDITIONAL INFORMATION. <br />SIMPSON LSTA24 STRAP w/ (8) 10d x 1 1/2" <br />NAILS TO STUD & (8)10d x 1 1/2" TO BAND <br />JOIST AT EA. STUD <br />2nd FLOOR WALL------ <br />BAND JOIST <br />*SIMPSON LTP4 w/ <br />(12) 8d x1 1/2" NAILS <br />@ 24" O.C. <br />1st FLOOR WALL <br />SIMPSON LSTA24 STRAP w/ (8) 10d x 1 1/2" <br />NAILS TO STUD & (8) 1 Od x 1 1/2" TO BAND — <br />JOIST AT EA. STUD <br />2ND FLOOR FRAME CONNECTION <br />@ WOOD 1 ST FLR. <br />UPLIFT CAP = 928 PLF <br />SHEAR CAP = 355 PLF <br />SEE J/S6 FOR ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />SPACER <br />BLOCKS <br />FEND SHEATHING TO <br />)F BEAM OR GIRDER <br />+TE W/ <br />O.C. <br />)OR TRUSS/JOIST <br />2"x BOT. PLATE W/ <br />(2)1 Od @ 6" O.C. <br />NOTES: * USE <br />LTP4 & EXTEND <br />SHEATHING TO <br />BOTTOM OF RIM <br />BOARD/BAND <br />JOIST FOR <br />SHEAR WALL <br />ONLY. <br />"T" CORNER <br />TYPICAL'IT" AND CORNER <br />DETAILS rN <br />SCALE: N.T.S. S6 <br />2ND FLOOR FRAMING - SEE <br />SECTION J/S6 <br />DECKING ATTACHED WALL SHEATHING <br />TO BOTTOM PLATE/CHORD W/ 8d <br />@ 4" 0/C, 2 ROWS STAGGERED <br />FLOOR TRUSS SEE FRAMING PLAN <br />FLOOR TRUSS <br />O° <br />SEE FRAMING WEEP SCREED <br />o _z r <br />PLAN .; • INSTALLED PER MANUF. <br />2"x4"CROSS BRACE @ 48" SIMPSON HETA20 w/ (8)10dx1 1/2" <br />O/C FOR THE 1ST 2'-0" OF NAILS @ 24" O.C. INTO TRUSS <br />END WALL W/ (2)10dx3" @ EA. BLOCKING & MIN. 4" EMBEDMENT <br />END INTO 2"x4" BLOCKING IN KO BLOCK <br />Tj <br />SEE DETAIL 2/D2 FOR <br />MORE INFORMATION <br />2ND FLOOR FRAME CONNECTION R <br />PARALLEL TO MASONRY WALL SCALE: 3/4"=V-0" S6 <br />SEE TYP. 2-STORY WALL SECTION <br />FOR ADDITIONAL INFORMATION. <br />2x STUDS @ 1" " " <br />2"x BOT. PLAT[ <br />(2)1 Od @ 6" 0.( <br />PRE-ENGINEE <br />FLOOR TRUSIc <br />FLOOR CONNECTION <br />ATTACHED WALL SHEATHING <br />CONTINUOUS TO BOTTOM RIBBON <br />W/ 8d @ 4" O.C., 2 ROWS STAGGERED <br />2X4 RIBBONS, EACH W/ 4-16d <br />NAILS INTO EA. FLOOR TRUSS <br />WEEP SCREED <br />INSTALLED PER. MANUF. <br />SIMPSON HETA20 w/ (8)10dxl 1/2" <br />NAILS AT EA. TRUSS w/ MIN. 4" <br />EMBEDMENT IN KO BLOCK <br />@ MASONRY 1ST FLR. SEE J/S6 SCALE: 3/4"=V-0" <br />FOR ADDITIONAL INFORMATION. <br />RIBBONS <br />DETAIL FLOOR TRUSS 0 <br />SCALE: 1 1 /2"=V-0" S 6 <br />NOTE: SEE TYPICAL WALL <br />SEE SHEATHING <br />SECTION C/S3 FOR <br />SPECS ON FLOOR <br />ADDITIONAL INFORMATION <br />1/2" GYP. W.B. MIN. @ <br />GARAGE SIDE IF APPLICABLE <br />2x BLOCKING HORIZONTALLY <br />@ INTERVALS NOT <br />5/8"DIA. x 10" "J" BOLT W/ 8" <br />EXCEEDING 1U-0" (R302.11) <br />EMBEDMENT @ 24" O.C. W/ <br />SIMPSON SP1 w/ (10) 10d <br />2"DIA.X 3/16" PLATE WASHER <br />NAILS AT EA. STUD <br />(MIN. SHEAR 3500#. MIN. <br />2 x STUDS @ 16" O.C. <br />TYPICAL TENSION 2600#.) <br />2X P.T. PLATE <br />6 x 6 W1.4 x W1.4 WWF OR FIBERMESH <br />. <br />.° O <br />Q <br />A <br />.a 'd'IIIT <br />I f <br />°..i <br />N—A <br />I=1 I <br />ITI= <br />III, , I I —III —III —III —III —I —(-(3) #5 CONT. ON 3" <br />8— I i I —I i I 1 i 8—ITI—I i t 8 Il CHAIR W/ 3" MIN. <br />CLEARANCE <br />INTERIOR 2-STORY FRAME SECTION rS <br />SEE TYP. 2-STORY WALL SECTION FOR SCALE: 3/4"=V-0" <br />ADDITIONAL SLAB INFORMATION. <br />15/32" OSB <br />EXPOSUREI <br />SHEATHING <br />x <br />PROVIDE <br />x <br />BLOCKING AS <br />REQUIRED PER <br />D <br />o SECTION X-X IF <br />NOT FULL <br />HEIGHT SHEET <br />C <br />m <br />Z <br />M <br />G FLOOR SYST <br />(2)- 2x TOP PLATE <br />BEYOND I <br />15/32" OSB <br />EXPOSURE F <br />F <br />SHEATHING w <br />[T <br />x <br />SOLID 2x <br />C <br />BLOCKING @ ALL <br />C <br />SHEATHING O <br />EDGES(SEE <br />OPENING <br />I SECTION X-X <br />a- I; <br />C <br />x <br />w <br />x <br />E <br />2x STUDS Lu <br />BEYOND. n <br />SEE PLAN o <br />L <br />L <br />O <br />\-2x4 P.T. BASE <br />2x RIBBON OR VERTICAL A HORIZONTAL PLATE BEYOND <br />BLOCKING SEE PLAN <br />BETWEEN FLOOR WALL SHEATHING <br />SYSTEM 1AfAI I r1 r\inTl^Kl nIAnnAAA <br />3/8" "S" = NAIL 3/8" <br />SPACING <br />=VS� 314" S 112„ <br />'I 'I 1/2" <br />S 1/2" <br />SINGLE NAIL EDGE SPACING DOUBLE NAIL EDGE SPACING <br />AT ALL PANEL BLOCKING <br />LOCATIONS SHALL BE MIN 2x4 #2 <br />SPF TURNED VERTICAL w/7116" <br />FLITCH PLATE TO w/ (2) 12d <br />TOENAILS EA. END. NAIL FLITCH <br />PLATE TO VERTICAL w/ (4) 8d NAILS <br />(2) 8d NAILS @ 3" O.C. <br />STAGGERED FOR SHEATHING <br />SECTION X-X <br />SFFp �0GL <br />2x CRIPPLES @ - <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />10d NAILS @ <br />8" O/C TYP. <br />DOUBLE 2x <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />ooFN�c R <br />WALL SHEATHING MAY BE INSTALLED VERTICALLY OR HORIZONTALLY, <br />ATTACH PER NAILING SCHEDULE. PANEL EDGES WILL NEED TO BE <br />ATTACHED TO STUD AND OR BLOCKING AT ALL EDGES. A MINIMUM" <br />SPACE IS RECOMMENDED BETWEEN PANELS AT EDGES AND END <br />w <br />JOINTS TO ALLOW FOR EXPANSION. FASTENERS SHALL NOT <br />I <br />PENETRATE SURFACE MORE THAW/8". <br />Z <br />? <br />OA NAIL AT BASE 2 ROWS @ 4" O.C. w/ 8d COMMON NAIL <br />O <br />© NAIL AT TOP PLATE TWO ROWS @ 4" O.C. w/ 8d COMMON NAIL <br />z <br />u- _ <br />© NAIL OPENING PERIMETER w/ (2) ROWS @ 4" O.C. w/ 8d COMMON NAIL. <br />O w <br />OD NAIL INTERIOR AT 6" O.C. w/ 8d COMMON NAIL. <br />ai <br />O STAGGER ALL VERTICAL JOINTS & NAIL @ 4" O.C. <br />J o <br />w/8d COMMON NAIL <br />J <br />Lu LL r O <br />PLYWOOD SPLICES @ HEADER - NAIL SHEATHING TO HEADER <br />F <br />} Q O U) <br />w/ 8d COMMON NAILS @ 4" O.C. (2) ROWS @ TOP & BOTT. <br />a:t-Oocn <br />H <br />Cn O w m w o <br />K LL <br />OG (2) 8d NAILS 3" O.C. TO EACH TRUSS END OR @ VERTICAL <br />GABLE <br />cam" w O O <br />MEMBER IF END <br />c " <br />NOTE: <br />WALL SHEATHING INSTALL. C . <br />S6 & NAILING SCHED. <br />REVISION 12-7-2020 <br />2-ROWS 12d NAILS <br />STAGGERED @ 12" O/C EACH <br />FACE OR 3-ROWS 12d NAILS <br />STAGGERED @ 12" O/C FOR <br />i — 2"x10" OR GREATER HEADER <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />(2) 2x HEADER SEE PLAN <br />S4 INTERIOR HEADER: <br />BOX HEADER (1) 2x SILL PLATE W/ (2) <br />ONLY 12d TOENAILS <br />• EXTERIOR HEADERS: <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(1) 2x SILL PLATE w/ SIMPSON <br />LS30 w/ (6)1 Od x 1 1/2" EACH SIDE <br />SEE PLAN FOR REQUIRED) <br />CONNECTIONS <br />LOAD BEARING/EXTERIOR FRAME <br />WALL HEADER DETAIL <br />2x STUDS TYP. <br />P.T. BOT. PLATE <br />FLOOR TRUSS / <br />2x BLOCKING HORIZONT <br />@ INTERVALS NOT <br />EXCEEDING 10'-0" (R302.11) <br />5/8"DIA. x 10" "J" BOLT W/ 8" <br />EMBEDMENT @ 24" O.C. W/ 2"DIA. <br />x 3/16" PLATE WASHER (MIN. <br />SHEAR 3500#. MIN. TYPICAL <br />TENSION 2600#.) <br />2500 PSI CONCRETE MIN. <br />SLAB W/ 6x6 W1.4xW1.4 <br />WWF OR FIBERMESH <br />C °, a.. ,• <br />• .d a e4 ° <br />M <br />-1 I I- I - I <br />a. <br />-I 1111 11 1 � 11111 ° `° <br />'�I,IIII -T�. <br />-III <br />(3) # 5 REBAR ON 3" CHAIR 4° V-8" <br />W/3" MIN. CLEARANCE <br />ALTERNATE FOOTING <br />M <br />S6 <br />• 8d NAILS FOR WALL SHEATHING MUST BE MIN .131 X 2 1/2 <br />DO NOT OVERDRIVE NAILS, FASTENERS SHALL NOT PENETRATE <br />SURFACE MORE THAN 1/8". <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />SIZE <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />SIMPSON <br />EA END <br />EA END <br />EA END <br />EA END <br />1'4 <br />(1) <br />(2) <br />(1) <br />(2) <br />(1) LSTA30 <br />4'-9' <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) LSTA30 <br />9'-16' <br />(3) <br />(3) <br />(2) <br />(3) <br />(2) LSTA30 <br />PLYWOOD SHEATHING NAILED PER NAILING <br />SCHEDULE SEE DETAIL C/S6 FOR MORE INFO <br />2X STUDS @ 16" O/C <br />7/8" STUCCO FINISH PER ASTM C. 926 <br />APPLY 3 LAYERS W/ TOTAL THICKNESS <br />7/8" OVER METAL LATH. FIRST 2 LAYERS <br />3/8" THICK EACH. 3RD LAYER 1/8" THICK. <br />SIMPSON SP1 w/ (10) 10d NAILS <br />AT EA. STUD <br />2X P.T. PLATE <br />WEEP SCREED INSTALLED PER. MANUF. <br />ll, FINISH GRADE <br />@ WOOD 1ST FLR. SEE J/S6 FOR SCALE: 3/4"=V-0" <br />ADDITIONAL INFORMATION. <br />0? <br />_I I - <br />o z <br />t� <br />.p <br />m <br />o r <br />� <br />v t6 <br />'� <br />LA_t3 <br />cc N t <br />Vl -O <br />G i <br />�y ✓'� 0 � <br />� o ✓ '� <br />c <br />C r- ¢ g <br />" <br />ego <br />M <br />CV <br />O <br />N <br />CV <br />r o <br />O "' 1 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />v E <br />O 0 <br />Q ' 8. <br />NO N o <br />0 00 C N n <br />w $ <br />Cn r 2 <br />M *h lL <br />& <br />d V C J LL W <br />(' w <br />— o <br />C� <br />Z � <br />r cao Z <br />o <br />�Wl ��6mLO LL w <br />` CD ¢ J <br />N M Z <br />0 do ¢ c� <br />x� W ❑ ❑ <br />M r <br />N th <br />o g <br />N <br />zo <br />� <br />Q s. <br />—1 <br />0- <br />(� <br />C3M <br />o <br />LLJ <br />U <br />w o <br />OW Ln a <br />N <br />ru <br />�3 <br />J E <br />— $ <br />to"... <br />= w <br />U o N <br />c M 0 <br />Op Y <br />N T <br />° <br />-® <br />4 <br />o <br />w <br />0! <br />M <br />J <br />t <br />Z <br />U_ <br />=o <br />2O <br />> <br />Qo� <br />I01 u <br />w� <br />Da <br />H- ro <br />20 <br />Uo <br />0 <br />oQ <br />�Z <br />�0 <br />QZ <br />�L <br />N <br />=Y <br />mo <br />co J <br />mo <br />¢w <br />.5 3 <br />< <br />ao <br />W <br />� <br />p <br />'0 <br />tt <br />z <br />mW <br />m <br />0 <br />R. <br />F ~ <br />�O <br />az <br />J <br />r� <br />=ti <br />�O <br />Mj <br />M <br />C <br />W¢ <br />" I <br />zl¢ <br />U <br />0 <br />0 <br />co <br />W <br />O <br />It <br />rn <br />0 <br />�Q U-) <br />T_ <br />N 0- <br />LO <br />0. 0 <br />N <br />I1 <br />Ll. <br />�J J m0 <br />a-•+ 0 <br />ILL�--+ <br />co <br />m 04 <br />Q 04 N <br />r <br />CO Lid <br />o <br />N <br />7 � to <br />Z <br />Z <br />E T <br />co <br />d <br />U Q o <br />JOB <br />NO : 23-04902 <br />SCALE : AS NOTED <br />SHEET NO. <br />S6 <br />(MONO) <br />