My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6720 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6720 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:47:25 AM
Creation date
2/19/2025 2:52:52 PM
Metadata
Fields
Template:
Building Plans
Street #
6720
Location
Back Forty Lp
Contractor
Lennar Homes LLC
Building Plans - Permit #
6514
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CROSS BRACING DETAIL (TYP)r1 <br />SCALE: N.T.S. <br />TRUSS NOTES: <br />CONV. FRAMED RIDGE <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. CB <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. pg <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP TRUSS BLOCKING DETAILS <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLOCKING NAILED @ <br />- EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 1 Od x <br />1 1/2" NAILS EACH <br />v 11I * 111 1-4 <br />13 <br />TB <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />MAX &EACH END ALTERNATE BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP - <br />w CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. <br />--�L WOOD TRUSS -J J <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: N.T.S. <br />DIAGONAL - <br />AT 8'-0" <br />MAX <br />TRUSS <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />10d TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2x4 SPF 2 (2) #7X 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 #2 SPF RIDGE BEAM <br />2x6 RAFTERS FOR SPANS 4FT TO 8FT <br />2X4 RAFTERS FOR SPANS LESS THAN <br />4FT @ 2'-0"0.C. MAX. w/ (3) 1 Od <br />COMMON TOENAILS TO BEAM <br />2X4 CONT. AT-/ CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL a@ INTERIOR BEARING <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />SEE FLOOR PLAN _`_j SEE PLAN FOR <br />FOR BRG. OR REQ'D STAIR INFO. <br />NON-BRG. WALL IF CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />SCALE: N.T.S. <br />K, <br />2x4 STUDS w/ SIMPSON <br />SP1 w/ (10) 1Od NAILS <br />AT BASE SEE J/S6 FOR <br />MORE INFO. <br />SEE ROOF PROVIDE 2X4 MIN. BLOCKING AT <br />PLAN SHEATHING Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />2X4 BLOCKING TYP. <br />BETWEEN TRUSSES TRUSS <br />SECT. A -A �A <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER JACK <br />USSES HIP <br />SIDE OR BOTH IF REQ'D) G.T <br />(2) 12D NAILS —y <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />SCALE: N.T.S. <br />WOOD POST. SEE FLR <br />PLAN FOR SIZE & BASE <br />CONNECTION SEE <br />PLAN <br />2 ENTRY PORCH SILL 14 <br />SCALE: N.T.S. <br />WOOD OR MASONRY ABOVE <br />MASONRY PIER SEE FLOOR PLAN <br />FOR COLUMN INFO WOOD OR MASONRY <br />ABOVE MASONRY <br />INTEGRATE M <br />KNEEWALL IN <br />MAIN HOUSE <br />REQUIRED <br />I MASONRY KN <br />COURSES w/ <br />w/ (1) #5 CON <br />REQ'D @ MID <br />I <br />I <br />I <br />ASONRY <br />T. <br />TO CMU BASE OR <br />PIER SEE FLOOR <br />PER ELEVATION IF <br />PLAN FOR COLUMN <br />�A <br />INFO <br />EE WALL MAX 3 <br />lop <br />TOP K.O. COURSE <br />CMU BASE W/ (1) #5 <br />FILLED CELL <br />VERTICAL EACH <br />SPAN MAX 6'-8" <br />CORNER FILLED <br />MAX 3 <br />SOLID. SEE ELEV. <br />COURSE <br />FOR BASE SIZE <br />(3) #5's EA. WAY <br />n <br />SLAB <br />PORCH SLAB SEE <br />FOUNDATION PLAN <br />LEVEL <br />Y <br />(2) #5's CONT T&B w/ <br />SEE CUT • ° `� <br />CONTRACTOR TO INSTALL #3 STIRRUPS AT 4'-0" <br />MIN 3" x 3" WEEP HOLE SECTION FOR WHEN DEPTH <br />ALONG w/ PITCHING SLAB MORE INFO EXCEEDS 30" <br />TO DRAIN WATER AL <br />1'-4" <br />KNEEWALL OPT. (ELEV TO INDICATE) MASONRY COLUMN <br />ENTRY PORCH SILL 16 <br />SCALE: N.T.S. <br />TOP COURSE TO <br />BE CHAIR BLOCKS. <br />ENTIRE BASE TO <br />BE FILLED SOLID <br />SEE ELEV. FOR <br />BLK HGT. <br />#5 REBAR CONT <br />@ SLAB LEVEL <br />EXTEND SLAB <br />1 1/2" BEYOND <br />BLOCK FACE <br />EXTEND <br />SLAB 1 1/2" <br />SIMPSON LSTA18 _ <br />w/ NAILS <br />SIMPSON HUC410 w/ (14) <br />T <br />LSEE PLAN III <br />OR CANT. <br />CENTERED AT <br />LIT O <br />SPLIT TO TIE <br />16d INTO HEADER & (6) <br />BEAMS TOGETHER <br />10d INTO BEAM - SEE <br />ROOF PLAN FOR MORE <br />INFO <br />—SEE FLOOR PLAN FOR <br />I <br />r <br />COLUMN SIZE & BASE <br />7116" OSB FLITCH PLATE <br />SEE FLOOR PLAN L <br />FOR COLUMN SIZE <br />CONNECTION INFO <br />REQ'D ONLY WHEN <br />INDICATED ON BM. <br />& ADDITIONAL INFO. <br />SCHEDULE/PLAN <br />7/16" OSB FLITCH PLATE <br />SEE FLOOR PLAN FOR <br />REQ'D ONLY WHEN <br />COLUMN SIZE & BASE <br />OPTION A <br />ON <br />OPTION B CONNECTION INFO <br />OPTION C <br />SCHEDULDE/PLANM <br />COMMON BM. TO POST ATTACHMENT <br />A <br />EXTERIOR SHEATHING <br />ATTACHED PER SEE ROOF PLAN <br />NAILING SCHEDULE FOR BEAM SIZE & <br />SCALE: N.T.S. <br />CONNECTION INFO. <br />BM. SPLICE OVER <br />`CENTER OF POST <br />PORCH SLAB SEE <br />EXTEND <br />2" <br />FOUNDATION PLAN <br />SLAB 1 1/2" <br />2x4 BASE PLATE W/ <br />a <br />SIMPSON w / <br />_ <br />a <br />io <br />22 1Od NAILS OR <br />( ) <br />r <br />2 #5 s CONT. T&B w/ <br />O <br />SIMPSON MTS12 w! <br />4r. - � <br />77 <br />_ .. <br />4 0 <br />I' r <br />4 , <br />� <br />- -- - ---- <br />(14) 10d x 1 1/2" NAILS <br />WHETNRDEPTHAT <br />Q -�� <br />TO FLOOR GIRDER <br />EXCEEDS 30" <br />PORCH SLAB SEE <br />N <br />BELOW @ 16" O.C. <br />GRADE <br />--_-.. <br />FOUNDATION PLAN -__ I <br />w X <br />- <br />•. <br />_ <br />_ <br />N z <br />cn <br />Z <br />-- -. <br />EE <br />w/ #3 STIRRUPS AT , <br />z_ <br />V-4" <br />4'-0" WHEN DEPTH <br />T <br />16" FLOOR SYSTEM <br />FLOOR GIRDER <br />EXCEEDS 30" <br />LOWER <br />SEE PLAN FOR <br />SEE PLAN FOR <br />S <br />GARAGE SLAB <br />DIRECTION <br />CONNECTION <br />1'-4" <br />SEE PLAN <br />AL <br />SECTION a@ <br />FLOOR <br />PORCH <br />SILL �� <br />LARGE STEP <br />DOWN <br />17 <br />CONNECTIONK22� <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />SIMPSON (2) HTS20 w/ (14) <br />1Od NAILS TYP. U.N.O. <br />SEE FLOOR PLAN FOR — <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />0 <br />° <br />CORNER SEE FOUNDATION <br />PLAN FOR MORE INFO <br />5" <br />COMMON BM. ATTACHMENT <br />SCALE: N.T.S. <br />W <br />MIDDLE <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />2X4 CONT. W/ (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />/TRUSS OR <br />/ ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL <br />SCALE: N.T.S. <br />2x4 #2 SYP NAILER. NA <br />TO STUDS w/ (3) 16d @ <br />EACH STUD - TOENAIL <br />EACH TRUSS TO <br />NAILER w/ (3) 10d <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />w/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY w/ <br />(3) ROWS OF 16d NAILS <br />AT 24" O.C. r. <br />1 �e <br />ROOF AND EXTERIOR SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />VERIFY FLOOR JOIST W/ RIM <br />BOARD OR FLOOR GABLE W/ <br />FRAMING PLAN <br />SIMPSON LUS26 w/ (8) 1 Od • <br />NAILS OR IF 2 PLY TRUSS SEE FLOOR FRAMING PLAN <br />SIMPSON LUS26-2 w/ (8) 16d AND J/S6 FOR MORE INFO. <br />NAILS TO LEDGER VERIFY WITH PLAN FOR <br />2X8 #2 SYP CONT. LEDGER W/ LOCATION AND DIRECTION <br />(4) 16d NAILS ATTACH NAILS (IF PARALLE SEE 2/D2 FOR <br />INTO END OF EACH FLOOR BLOCKING INFO) <br />TRUSS, 24" O.C. MAX. (AT EACH <br />SIDE OF G.T. INSTALL (4) NAILS MASONRY WALL <br />EACH SIDE) (TYPICAL) <br />SECTION AT LOW ROOF 9 <br />SCALE: 1/2" = 1'-0" <br />I--- <br />Y2" CDX PLYWOOD OR 7/6" O.S.B. <br />SHEATHING REQ'D FROM BOTTOM <br />OF WALL TO ROOF SHEATHING <br />ABOVE W/ 8d NAILS @ 4" O.C. IN <br />FIELD, EDGES & BOUNDARIES <br />SEE PLAN MAX. <br />24" STEPS <br />SEE PLAN FOR OPT. <br />STAIR INFO. IF <br />CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />4, 4 <br />c N � <br />GARAGE OR ,- <br />LOWERSLAB <br />SEE PLAN. <br />COMMON TRUSS <br />W/ INTERIOR BRIG. <br />SEE PLAN FOR <br />CONNECTIONS <br />INFO. <br />BUSS/ <br />OP WALL <br />EE PLAN <br />MIN. (2) 2x8 #2 SYP <br />HEADER. SEE Q/S4 FOR <br />REQ'D CONNECTIONS <br />2x4 #2 SPF STUDS @ <br />12" O.C. W/ USP SPT22 <br />@ BASE & SPT24 @ <br />TOP <br />2x4 #2 SYP P.T. PLATE W/ <br />EPDXY ANCHOR OR <br />2„ J-BOLT OR Y2" TITEN HD <br />ANCHOR @ 24" O.C. W/ <br />MIN. 6" EMBEDMENT <br />a - <br />4. d O <br />A.p 4 Q , <br />` 4 MAIN HOUSE <br />4: 4 4. <br />(2) #5's CONT. T&B <br />4 w/ #3 STIRRUPS AT <br />Q <br />® a 4'-0" WHEN DEPTH <br />EXCEEDS 30" <br />� 4 <br />g. <br />4 : .Q <br />4 <br />V-4" <br />SECTION GARAGE MONO 21 <br />SCALE: N.T.S. <br />.00 <br />d r' <br />o,."to <br />r <br />co <br />s� <br />m R <br />1 ' <br />M <br />N <br />0 <br />N <br />O <br />o <br />l <br />hf . <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residentiai 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />B ° <br />N m c0 n <br />�Co <br />u <br />�snZti <br />N <br />q c J <br />W <br />LL , W <br />JCLjJ <br />� --dam a Y <br />Z ��o3 <br />a y o <br />W o 2 1—� O <br />W U5 C (3)m <br />Z Z?5 M z Q <br />N OU 8 <br />Z <br />W ❑❑ <br />0 M <br />Z N � <br />oJim <br />� a � <br />J <br />M <br />cn <br />o� <br />N <br />N L'� <br />U <br />r — J 0 <br />z <br />U <br />N 'M <br />a <br />o <br />w <br />z <br />z <br />caE <br />�o <br />Joao <br />>N <br />Q O <br />Sw <br />z© <br />tC6 m <br />C:> <br />g <br />00 <br />S Q <br />0 <br />L <br />0 <br />w� <br />p <br />�Z <br />W� <br />,� <br />¢o <br />U <br />mo <br />) <br />S <br />Q� <br />O <br />�Z <br />z° <br />< <br />LL <br />rnF <br />A <br />® <br />w <br />¢o <br />= <br />a <br />w< <br />>° <br />a= <br />VM <br />zla <br />�O <br />.o <br />= <br />> (o <br />�' <br />CU <br />CU <br />c� <br />CID L i <br />N C- <br />In <br />Q <br />Y $ <br />N <br />a <br />m 't <br />o <br />Ln <br />_ <br />a-.+ ILL <br />� <br />d' <br />0 <br />ccaa <br />Q <br />CDLO <br />CD 04 <br />Q N N <br />T <br />m <br />�.F (0 t) <br />a <br />Z <br />z <br />V N <br />E r <br />I° <br />a <br />o <br />U Q p <br />JOB <br />NO: 23-04902 <br />SCALE : AS NOTED <br />SHEET NO. <br />D 1 <br />(MONO) <br />„I III :l I LIII III 1111 11111 I'll i141 11 IIIJ1 I'll... L' Il I I JT . 11 I, I <br />
The URL can be used to link to this page
Your browser does not support the video tag.