My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6802 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6802 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 3:02:14 PM
Creation date
2/19/2025 2:53:30 PM
Metadata
Fields
Template:
Building Plans
Street #
6802
Location
Back Forty Lp
Contractor
Lennar Homes LLC
Building Plans - Permit #
5930
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />WALL SHEATHING <br />r <br />.I. I . ... 14 1—'I� <br />II•.......:. ...:I.�.::..:... ...�.��....: <br />.. <br />16GAx1-1\2" LONG 3/4"-1"CROWN) 8�... ..:.:.:.. <br />( ..... <br />MAX.......:.�.'.........L......:.:.:. : 16GAx1-1/2" LONG 3/4" 1„ <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:—) -OFFSET CROWN) STAPLES @ 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />*"ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE O O O <br />5'-0" cc - <br />c� <br />STUB -OUT FOR 0 ° o <br />GAS METER O - o <br />_ U <br />O F <br />N oo <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3) 16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />&-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />154" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCIOJoist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" orp <br />5000s 1.8/1.7 <br />nel <br />wood panels <br />Two 3/4" wood panels or 2 x <br />P <br />1-1/8" or two 1 /2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 314" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1 /2" <br />602.0 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking / <br />1/8" gap ---, / <br />FILL CELL STD. 90° HOOK BOND BEAM <br />w <br />F <br />STD. 90° CONT. #5 <br />CONBAR T. #5 7 7L <br />I HOOK �BAR <br />#5 CONT. <br />u FROM <br />NDATION <br />TOUHIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN SEE PLAN FOR REQ D PLYWOOD FLOOR <br />COLUMN AND SHEATHING PER PLAN <br />CONNECTION TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. )Small gap 2" min. <br />2" max <br />4 max. <br />i <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2" min. <br />required when indicated or 4" max. <br />2x_; CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING%" GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION-Under2ndfloorco N.T.S. <br />- Under 2nd floor column w/loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES --� <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Q�'/ Provide adequate bearing <br />for each lapped joist. <br />Odnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />Series Depth End Intermediate <br />BCI5000s® <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/9" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />1 5-8d <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />! 2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />5-8d <br />BCI60s� <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC190s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/(22)' <br />NAILS 7 <br />5/8" � <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />OP PLATE <br />�.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT—UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />AIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />111L <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />L Joist <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I Joist can be offset <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />co <br />6 A 1Y2" ROUND HOLE MAY 6 { 6" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1)/2" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS, <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2' <br />Actor 16' loist <br />Span (ft) <br />V <br />1-3" <br />V-7' <br />1'41 " <br />2-4' <br />2-9' <br />3 7' <br />3 7 <br />12 <br />1'-U' <br />V-1" <br />1 2" <br />1-2," <br />1'-3" <br />T-9' <br />2-4' <br />2-11" <br />37" <br />4, Z' <br />4'4' <br />64' <br />16 <br />1'-O" <br />I"" <br />1' 2' <br />1 Z' <br />1' 7'. <br />2'- <br />3-2' <br />3-10" <br />4-9" <br />5-7" <br />64' <br />72" <br />-1" <br />1' T <br />1'-2" <br />2'-Q" <br />3-U <br />4'4]" <br />4'-itt" <br />5-11" <br />B-11" <br />24 <br />1'-0 <br />1'-T' <br />1{ 2. <br />1,_3," <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO, <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1%" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Joist hanger <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />a <br />,a w <br /><� FINISH GRADE <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />Install tight to top flange. SLEEVE THRU STEM ° <br />1 SEE PLAN FOR °. a . • • a <br />FOUNDATION INFO a ° <br />STEM FOUNDATION <br />i <br />-GRADE REINF. SEE PLAN <br />Fill bI k <br />\ l it oc <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4%2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />`0.6 X Joist <br />6 / depth <br />i D <br />I -JOISTS BUCKETS <br />N.T.S. <br />4 <br />d <br />—rT <br />11=7- <br />d Ililllll <br />A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />:�® LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4' 0" <br />CENTERED @ PIPE <br />PENETRATION <br />d a <br />1�IIII—I <br />"-II-IIIIIlllll • <br />PLUMBING LINE <br />i—PVC OR SCH40 SLEEVE <br />V. <br />- <br />d . <br />° <br />I —III= <br />I'T I III. I <br />d <br />I- <br />� <br />i SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4' 0"—\ <br />CENTERED @ PIPE <br />PENETRATION <br />° <br />PVC OR SCH40 SLEEVE <br />/ r PLUMBING LINE <br />CO d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />_\ <br />CENTERED @PIPE <br />PENETRATION PLUMBING LINE <br />°. <br />4 44. d d° G <br />d <br />-i 1=1 1=1I I1=III—III: <br />-III,IIIIIII� d ° d 4 ° �IIIIII III- <br />-I <br />° <br />SEE FND. PLN. <br />SIZE & REINF. <br />+rs <br />0 <br />Cr <br />N <br />� <br />o <br />Q <br />� -o <br />o s <br />m <br />�e <br />H secs. <br />N 6i O tYi <br />-CZ <br />u Fu <br />c E <br />.E"�. 6 �t�•f <br />a za�`R <br />r <br />y.6j <br />O� <br />C.p a .•�. <br />'il����\\ <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />,4 �' <br />`° , W <br />E <br />p M <br />4J7 -f <br />1 <br />V <br />O N <br />N O 6 0 <br />N <br />. In <br />si tir-a <br />C J LL u- W <br />0 u_ w a <br />m C� o U) <br />Z <br />0O <br />19 <br />_ 2 <br />z O <br />ca <br />W <br />m w <br />r$ <br />ZLO <br />IL <br />co C) <br />N Q <br />M 0 <br />ka <br />Z <br />N <br />O U 0 o <br />W <br />U to <br />❑ ❑ <br />M <br />o o <br />z <br />(D <br />z o � <br />Q <br />J — <br />(LE3N <br />N <br />z <br />o <br />Q) <br />d <br />4 <br />f13 <br />LL, W <br />_(D O <br />Ln <br />w o <br />C1 <br />y... <br />pp <br />U ) <br />o <br />� <br />z <br />w <br />M <br />M <br />D Z <br />o S <br />z <br />Z <br />Q <br />�o <br />�q <br />o <br />p <br />M tJ <br />w� <br />z <br />zp <br />❑a <br />F— (O <br />*0 <br />00 <br />E <br />&< <br />o< <br />ao <br />�Z <br />mo <br />o, <br />C <br />Z <br />'< w <br />J <br />8 <br />Q b <br />O � <br />�z <br />Z. <br />T <br />oW� <br />U <br />nw <br />W <br />O <br />0 <br />=O, <br />S F <br />w <br />3 <br />=H <br />�0 <br />o <br />M <br />w� <br />zIa <br />; <br />a, <br />o <br />(D <br />T <br />'M <br />J <br />O <br />CU <br />CU <br />c� <br />co <br />LO <br />N <br />CT <br />o <br />0 <br />i--+ <br />O <br />L i <br />0 <br />ll <br />r_1 <br />M <br />O <br />,Q <br />(a <br />m <br />0 <br />LO <br />CAI <br />< <br />N <br />0O N <br />T— <br />m <br />E <br />E <br />C.O <br />o <br />z <br />c6 <br />z <br />E 10C <br />iti r <br />m <br />E <br />4) <br />0- <br />U J <br />Q <br />JOB <br />NO : <br />23-00509 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.