Laserfiche WebLink
i - - - I _-_ - I L_ I 1 :I 1 loll 1'f1111�1 [ <br />W. <br />KITCHEN <br />MIRROR <br />0 0 <br />0 <br />Q 50 <br />0 <br />M <br />O. BATH <br />VARIES, 2" LESS THAN <br />CABINETS BELOW <br />T <br />MiRROIR <br />VARIES <br />KITCHEN <br />INTERIOR DETAILS <br />NOTE: THIS DIAGRAM DEPICTS TYPICAL INSTALLATION <br />GUIDELINES TO BE FOLLOWED U.N.O. ON PLANS <br />_T <br />F <br />SHWR. SHWR. DOUBLE <br />CURTAIN HEAD RODS <br />ROD p <br />24" TOWEL BAR <br />� TOWEL BAR IN <br />w ON WALL ABOVE TUB OR SHWR. <br />TOILET TOWEL BAR - <br />ON BATHROOM WALL <br />MEDICINE 4 I SHWR. o r <br />6D VALVES <br />CABINET <br />TOILET <br />PAPER <br />° <br />° <br />SOP <br />DIS <br />I HOLDER <br />`? <br />y <br />n <br />02 <br />02 <br />o <br />O% <br />u- i <br />O <br />h <br />O <br />n <br />M <br />iv <br />TUB <br />FIN. FLR. <br />BATHROOMS, SHOWERS AND TUBS <br />SINGLE <br />ROD <br />op <br />i0 <br />CLOSETS/LAUNDRY <br />BATHROOM 2 <br />42" H UPPER <br />CABINETS <br />36" H UPPER <br />CABINETS <br />30" H UPPER <br />16" FOR LINEN <br />CABINETS <br />12" FOR PANTRY <br />OVERHANGS THAT <br />EXCEED 12" MAY <br />REQUIRE A SUPPORT <br />cc <br />BRACKET 36" H BASE <br />O <br />00 <br />FINISHED CABINETS <br />COUNTER TOP 30" H BASE <br />o <br />4 <br />4 <br />co <br />CABINETS <br />o <br />°D <br />LL <br />N <br />n <br />r; <br />in a <br />O <br />2x <br />M <br />� <br />FRAMING - <br />7' o <br />1/2" GYP N M N <br />V <br />? <br />BOARD <br />FIN. FLR. <br />FIN. FLR. <br />X <br />SHELVING <br />ISLAND COUNTER CABINET BLOCKING <br />BLOCKING AND MOUNTING DETAILS <br />SCALE: 1/4" = V-0" <br />AC PAD <br />12'-0" 13'-0" <br />8'-3" 3'-9" 11'-8" 1'-4" <br />--NOOK <br />8'-8" FLAT CLG. <br />TILE <br />I <br />------------------------ <br />I ri <br />LANAI <br />8'-0" FLAT CLG. AFF <br />12'-4" <br />FAMILY <br />8'-8" FLAT CLG. <br />CARPET <br />1'-4"X1'-4" "L" <br />SHAPE CMU <br />COLUMN <br />=� i <br />_ <br />rn <br />Lh <br />N <br />N <br />8'-8" FLAT CLG. _ `' - S6 <br />TILE <br />TYP. @ 2 <br />1 FLOOR G.T. J- STORY. SEE <br />REF171!1 STEMWALL <br />2 <br />(3) 2x4 #2 SPF <br />I N I N G <br />STUDS w/ (3) 16d <br />GG <br />NAILS @BASE <br />8'-8" FLAT CLG. <br />1 <br />S3 f" <br />CARPET <br />0 TYF <br />17 zo <br />_- <br />T-3„ <br />42" H 1/2 WALL <br />= <br />4'-2 " <br />OR RAILING PER <br />o <br />SPECS <br />LO <br />M <br />(.0 <br />FLOOR G.T. <br />-�_ <br />---- -- <br />---- _- - _-- -- <br />O <br />- <br />-_ <br />U <br />I0 <br />Cr <br />(3) 2x4 #2 SPF ■ <br />N <br />STUDS w/ (3) 16d <br />NAILS @ BASE <br />WIRE SHELF @ <br />1 <br />+54" A.F.F. <br />-_- <br />_ �l, ,, 11 f4tl <br />PLUMBING LINE <br />- <br />- <br />4068 -- <br />GG ! <br />_ I <br />-PW R - - , <br />_ <br />f <br />TO SECOND <br />- <br />I <br />-ARCH <br />D S3 __ _- <br />--- _-- O <br />8'-8" FLAT CLG. <br />8 3 2x4 #2 SPF <br />`D <br />FLOOR <br />I <br />� � <br />„ - - <br />?6� - TIL - _STUDS w/ HTT16 <br />r <br />DRYER VTE <br />--_ <br />_ <br />I _'� _ - 00 <br />LAUN <br />c <br />o AT BASE it <br />-� _ _ _L. �_ <br />TP FOYER <br />E NK <br />�I <br />- Q <br />-_ - <br />HANSON BOX @ <br />_ <br />I <br />8'-8" FLAT CLG. <br />o j- I 8'-8" FLAT CLG. <br />36" A.F.F. <br />TILE -S4 <br />' <br />� TILE <br />rlIr 111111 I <br />SW <br />H1 <br />EXTERIOR WALL <br />-- <br />3 <br />T-24, <br />4-0„ <br />1 <br />6'.74, <br />- <br />W/ 2x4 WALL z LU <br />- - i 6 4' <br />W.H. <br />17' <br />Z <br />PAD OUT <br />,- <br />10 <br />-N <br />_ <br />BUILDER TO 35 <br />U Q <br />EDGE OF SLAB 2" <br />U <br />--- <br />PROVIDE APPLIANCE D1 <br />BEYOND WALL _■ _ �1_ <br />U <br />-- <br />PROTECTION WHEN <br />F <br />O <br />- <br />REQUIRED PER FBC <br />NOTE: FINISHED WALLS - 00 <br />_ w <br />0 > <br />TO BE FLUSH. FIELD M I <br />8'-8" CLG. A.F.F. <br />G.T, VERIFY. I <br />_ <br />----------------------- <br />( <br />O I <br />`r <br />8'-0" CLG. A.F.F. <br />U <br />� <br />o <br />C) ____JENTRY <br />LU 2 z �F rs4-1�c2 -1 <br />'-0" FLAT CLG. AFF <br />_ <br />° ATTIC I <br />GARAGE ------ <br />cc U <br />F_-L J <br />8'-0"CLG. A.F.F. <br />>�� <br />80 <br />TYP. @ SINGLE o <br />1'-4"X1'-4" "L" <br />STORY <br />SHAPE CMU <br />A (SEE AA/S3 FOR <br />4'4" 1'4" <br />COLUMN <br />S3 STEM OPT.) <br />50 <br />rh <br />1------------------ <br />--------------I <br />r <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I K <br />I <br />I <br />I <br />I <br />I S4 TYP.@ <br />I <br />HB <br />' GARAGE <br />j <br />q <br />I <br />O I <br />ch <br />16070 OVERHEAD DOOR <br />Iillm <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />h 15 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 114" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 314" X 7 114" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2' <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />AC� <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />C�D <br />+28.3 / -37.0 <br />DE <br />+26.6 / -29.1 <br />O <br />+26.6 / -33.5 <br />O <br />SEE SN SHEET SEE SN SHEET <br />W& <br />jk;16iiiiW <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />18�X252 <br />S.H. <br />13 <br />20 X 38 8 <br />18' X 37 4 <br />S. H. <br />14 <br />20X50g <br />182X50 <br />S.H. <br />15 <br />20 X 63 <br />18' X 62' <br />S. H. <br />16 <br />20 X 72 <br />181 X 71 2 <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 z <br />S.H. <br />1H3 <br />271/4X383 <br />26x374 <br />S.H. <br />1 H4 <br />27 4 X 50 g <br />26 x 50 <br />S.H. <br />1 H5 <br />27 4 X 63 <br />26 X 62 1/2 <br />S.H. <br />11H6 <br />274X72 <br />26X711/2 <br />S.H. <br />22 <br />37 4 X 26 <br />36 X 25 1/2 <br />S.H. <br />23 <br />37 4 X 38 8 <br />36 X 37 3/4 <br />S.H. <br />24 <br />37 4 X 50 s <br />36 4 X 50 <br />S.H. <br />25 <br />37 4 X 63 <br />36 � X 62 1/2 <br />S.H. <br />26 <br />373X72 <br />362'X711/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 2'WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 X 25 <br />S. H. <br />33 <br />54X388 <br />52 X374 <br />S.H. <br />34 <br />54 X 50 a <br />52 i X 50 <br />S. H. <br />35 <br />54 X 63 <br />52 X 62 z <br />S.H. <br />36 <br />54 X 72 <br />52 X 71 z <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />FIRST FLOOR PLAN -A <br />SCALE: Y4'=V-0" <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelfing/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090, <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min, of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY HGT. @ 8'-0" A.F.F. <br />MEMEEMMMMEMM TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST FLOOR LIVING AREA 952 S.F. <br />SECOND FLOOR LIVING AREA 1121 S.F. <br />TOTAL LIVING AREA 2073 S.F. <br />GARAGE 396 S.F. <br />LANAI 104 S.F. <br />ENTRY 32 S.F. <br />TOTAL SQ. FT. 2605 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />M <br />CV <br />C= <br />N <br />LO <br />04 <br />c <br />Ck' 'a <br />Q d-0 <br />> W <br />c. <br />a <br />C co C-2 <br />N <br />- m x <br />LL <br />C1 <br />N C <br />(c i <br />y N <br />N W p <br />ar _ <br />Q, a °' <br />oc <br />= E <br />c <br />iillliRt�Pi�'� <br />r 0 <br />M <br />ev (C o <br />-. <br />\l' , Cn <br />r <br />r` <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and sea]. <br />n <br />' F o E <br />4 CD co <br />` <br />N N <br />li st 1 ® 07 N N_ -1 <br />to U) <br />� <br />LU <br />_J tIJ <br />fna' z Z m e a <br />0 <br />W ink°'°' <br />:. <br />co.� Z <br />F- <br />O <br />O V <br />U <br />s ,1z1 <br />k"i'\]YYid1 i\4 4�(y",Y,�!'2F W <br />C7 <br />z N M <br />o <br />z <br />z iz- <br />J <br />h <br />U <br />c� z G <br />_ o <br />�(1) U <br />N <br />w <br />� <br />U <br />0 w0-' o <br />V/ L/ N <br />U c <br />�!•M, <br />K �, 1 1 J <br />U <br />C a0 <br />¢ N <br />MID <br />. <br />m <br />o <br />W <br />� <br />J <br />¢ <br />Z <br />< <br />co E <br />cof <br />wo <br />Q0 <br />Q O <br />EE V <br />sLL <br />z© <br />❑ a <br />9 ro <br />�g <br />00 <br />o E <br />� ra <br />&4 <br />0o � <br />°z <br />f- <br />w� <br />o <br />CID ra <br />� <br />�z = <br />a <br />m� <br />0 <br />0, <br />m a, <br />J <br />�1 <br />10. <br />1w <br />� z <br />oho <br />5. <br />Z <br />m <br />aZ <br />- <br />o <br />wa <br />yo <br />M <br />d F=- <br />d <br />zla <br />o 3 <br />�� <br />'M <br />J <br />O <br />iu <br />0)�- ca <br />T <br />ca <br />N <br />M <br />0 <br />N o <br />�- Y o <br />O <br />a. <br />O <br />L O <br />LL <br />O <br />_�d <br />p <br />co N <br />m <br />0) <br />N <br />Ln <br />NCN <br />Q CDoo N <br />E <br />-E `° � <br />° <br />M <br />Z <br />N r <br />:3O N <br />C <br />m <br />d <br />E v N <br />U J Q 0 <br />c <br />J <br />JOB <br />NO: 23-00509 <br />SCALE : AS NOTED <br />SHEET NO. <br />1.� <br />