I I L_ 1 __L__ Lr -___ I <br />H <br />WALL LEGEND <br />8'-8" TOP OF MASONRY WALL <br />(GARAGE) <br />9'-4" TOP OF MASONRY WALL <br />18'-8" TOP OF MASONRY WALL <br />FLOOR18'-8" TOP OF MASONRY WALL <br />ONLY. • FIRST <br />••B• <br />_ -2HOUR FIRE RATED SEPARATION <br />WALL <br />44" TOP OF MASONRY WALL <br />(LANAI) , W/ SHAFT LINER ABOVE <br />TO BOTTOM SIDE OF DECKING <br />-2HOUR FIRE RATED SEPARATION <br />WALL <br />-18'-8" TOP OF MASONRY WALL, W/ <br />SHAFT LINER ABOVE TO BOTTOM <br />SIDE OF DECKING <br />-2HOUR FIRE RATED SEPARATION <br />WALL <br />-20'-0" TOP OF MASONRY WALL, W/ <br />SHAFT LINER ABOVE TO BOTTOM <br />SIDE OF DECKING <br />TYP. INTERIOR WALL <br />BEARING WALL <br />I <br />I <br />I <br />L_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ <br />(1666) <br />SYMMETRICAL <br />SYMMETRICAL <br />I <br />I <br />I <br />_ _ _ _ — _ _. — — — — — — — — — — — — — — — — — — _J <br />2nd FLR ELECTRICAL PLAN <br />SCALE: Y"=1'-0" <br />Riser Diagram <br />4 UNIT BUILDING <br />2/0 CU GEC <br />CONNECTED <br />TO LIFER AND <br />(2) RODS <br />600 AMP <br />SERVICE <br />00 <br />150 AMP <br />O0 <br />150 AMP <br />150 AMP <br />150 AMP <br />(2) 3" SCH 80 PVC CONDUITS <br />WITH (2) 500 MCM XHHW AL <br />AND (1) 350 MCM XHHW AL <br />EACH CONDUIT <br />(4) METERS PER BANK <br />(1) METER BANKS PER <br />4-UNIT BLDG. <br />(1) 1 J" SCH 80 PVC CONDUIT <br />WITH (2) 2/0 XHHW AL <br />(1) #1 XHHW AL <br />(1) #4 XHHW AL <br />TYPICAL ALL UNITS <br />NOTE: <br />• ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH <br />APPLICABLE PROVISIONS OF THE NFPA 70 - 17, LOCAL CODES AND <br />THE LOCAL POWER CO. <br />• INSTALL 2" CONDUIT TO METER CAN <br />• INSTALL A MAIN 150 AMP BREAKER IN PANEL <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FE�IW <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />�3 <br />THREE-WAY SWITCH <br />�'4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />F_o <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />�--� <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />D� <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />TV 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />wn <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />L J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />e013 <br />N <br />0 <br />c� <br />Z <br />o <br />i r U <br />` a C_ o <br />i c M t- <br />N Q N .I~ <br />cc LJ <br />N <br />G., <br />� G <br />61 G9.1 a -a tC <br />CU <br />i✓ � G ,.7 <br />� LL' •A A <br />T E <br />+a ry <br />A <br />N <br />CV <br />0 <br />N <br />N <br />N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />- <br />Q <br />$ <br />V <br />d S <br />co <br />y0 <br />N O ib LL <br />4 <br />=u LL w <br />u r' a <br />Z <br />a Sc <br />m = <br />�o <br />�•�Nrp O <br />cp <br />Z <br />LLto <br />Co <br />Cv Z d <br />Cl)� <br />Z <br />N <br />OU 0 <br />W <br />❑❑ <br />(� <br />0 <br />iz, S <br />L NE3 <br />J � ZZZ <br />a <br />W <br />O <br />w <br />V <br />N <br />�N <br />r <br />� <br />v � <br />L <br />MEM <br />V- <br />90C <br />Z <br />J <br />E90 <br />GG <br />a <br />LL <br />y2y N <br /><N <br />O <br />V <br />wz <br />Z <br />❑a <br />f9 <br />r0 <br />,O <br />a <br />U O <br />E <br />n <br />Cn <br />0u <br />z <br />• J <br />ab <br />b <br />Fz <br />Qo <br />= <br />S <br />o <br />a = <br />�U <br />b= <br />O <br />=CV <br />O <br />> M <br />0 <br />ai <br />= <br />J <br />LL <br />CY) <br />cc <br />cc <br />Q <br />F— <br />O <br />t� <br />r� <br />ICU� <br />O <br />rpQ <br />T ( <br />0 <br />c <br />: <br />O <br />O <br />Q <br />4_j <br />cr_ <br />CV <br />I--- <br />LO <br />o O <br />O <br />C) <br />N N <br />.Ira <br />I <br />Q = <br />r <br />ai <br />m <br />c � <br />n CV <br />o <br />c <br />CD <br />>u <br />c <br />M <br />a <br />E <br />U _j <br />ai <br />Q 0 <br />JOB <br />NO: 22-12492-12489 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />15 <br />