'DIAGONAL SPACED <br />AT 15'-0" O.C. MAX <br />CONTINUOUS LATERAL <br />BRACING- NAIL OVER <br />X-BRACE AS SHOWN - <br />INSTALL BLKG. AT TRUSS <br />WEBS FOR NAILING <br />SEE ROOF <br />PLAN SHEATHING <br />BLOCKING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />X-BRACING - 2x4 SPF OR <br />SYP w/ 2-16d @ EACH TRUSS <br />WEB <br />CROSS BRACING DETAIL (TYP.) <br />SCALE: 1/2" = V-0" <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�7A TRUSS <br />USSES <br />(2) 12D NAILS —} <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL r <br />SCALE: 1/2"=V-0" <br />TRUSS NOTES. <br />TYP. HAND FRAMING ABOVE TRUSS <br />1. <br />WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 <br />CONV. FRAMED RIDGE 2X4 STUDS & PLATES AT 2'-0" O.C. <br />MAY BE NAILED EACH DIRECTION TYP. U.N.O. <br />TRUSS PLATE INSTITUTE NOTE THAT THE COMBINED WIND AREA IS GREATER <br />( ) <br />W/ MIN. (4) 12d WHENIT <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE <br />LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST <br />PRE-ENG. TRUSS 2x8 BLKING. NAILED @EACH <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SIDE w/ (3) 12d NAILS WHEN <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />REQUIRED w/ (2)ILSWHEN <br />SIMPSON HTS20 <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />W/ (14) - 10d X 1 1/2" EACH <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />�C <br />2. <br />ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTURER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. <br />ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D <br />NAILS AT EACH TRUSS INTERSECTION. <br />Cg <br />4. <br />ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />TB <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. <br />pg <br />g <br />5. <br />PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />BETWEEN EA. TRUSS <br />CONT. ROOF SHEATHING AT TRUSS TOP <br />MAX &EACH END ALTERNATE <br />DIRECTION TYP. � <br />w <br />CHORD AT ALL HAND FRAMED AREAS TYP. <br />----/—WOOD TRUSS <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: 1 /2"= V-0" <br />2 x P.T. BLOCKING BY FRAMER FOR <br />PLYWOOD EDGE NAILING w/ (2) 1/4"x3" TITEN2 <br />HIP <br />G.T <br />VERTICAL SCAB <br />2 x 6 #2 SPF 48" O.C. <br />W/ (4) 10d TOP & <br />BOTTOM OR SIMPSON H2.5A <br />W/ (10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2x4 SPF 2 <br />(2) #7X 3-1/2" WOOD <br />SCREW EACH TRUSS <br />OR SIMPSON H2.5A @ 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />DIAGONAL 2x8 #2 SPF RIDGE BEAM <br />AT 8'-0" WOOD <br />MAX TRUSS �C it 2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO RIDE BEAM <br />2X4 CONT. AT—/ CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL a@ INTERIOR BEARING <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />(2) SIMPSON SDWC15600 SCREWS PROVIDE LAP <br />�° F. SPLICE @ F.C. REBAR <br />EACH TRUSS TO LEDGER <br />1/2" GYP. WB <br />OR 3/8" PLYWOOD/ TYPE 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/8d <br />TOP -CHORD BEARING <br />COMMON @ 6" O/C TO ONE SIDE OF THE <br />FLOOR TRUSSES @ <br />FLOOR TRUSS FOR AN <br />24" O.C. <br />AREA <_ 1000 SQ. FT. OF <br />FLOOR AREA & SEALED <br />PENETRATION AREA W/ <br />2) 2x8 SYP #2 P.T. <br />FOAM. DRAFTSTOPPING0 <br />LEDGER ATTACHED TO <br />SHALL DIVIDE THE <br />MASONRY w/ (2) ROWS <br />CONCEALED SPACE INTO <br />1/2" SIMPSON TITEN HD, <br />APPROX. EQUAL AREAS. <br />MIN. 5" EMBEDMENT PER <br />54/D1 SPACING. <br />DOUBLE KNOCK -OUT <br />BLOCK w/ (1) #5 CONT. <br />IN EACH COURSE. <br />r 1 �\ /\ r\ /\ A \ ■ \ 1 .� /\ T 1 /\ ■ 1 r\ <br />�— \ IT <br />�� ■1 <br />1 <br />/\ /1 ■ ■ / A 1 1 / — w \ <br />SCALE: 3/4" = V-0" <br />L <br />SCALE: 1/2" = V-0" <br />2'-0" MIN. <br />LAP SPLICE <br />1'-0" 6" 6" 1'-0" 6" 6" <br />x 6- <br />TYP. <br />O O 1 O O <br />I SPLICE <br />O 1 O O <br />2.0 SPLICE BEYOND <br />00 <br />PART. ELEV. VIEW <br />F", n r <br />n.. <br />DBL. KO. BLOCK MIN. <br />n <br />MIN. TYP. <br />0 <br />D <br />� <br />24" MIN. <br />(2) 2x8 P.T. <br />ATTACHED <br />(2) 2x8 SYP #2 P.T. CONT. <br />LEDGER w/ (2) ROWS OF 1/2" <br />TITEN HD STAGGERED @ 24" <br />O.C. w/ 5" EMBEDMENT & 6" <br />EACH SIDE OF SPLICE & <br />EACH END. <br />LEDGER <br />LAP SPLICE TOGETHER w/ <br />PART. PLAN VIEW (2) ROWS OF 10d @ 6" O.C. <br />LEDGER SPLICE DETAIL 54 <br />SCALE: 3/4" = V-0" <br />PROVIDE 30" LAP SPLICE <br />@ F.C. REBAR. <br />(2) ROWS OF 10d NAILS @ 4" O.C. <br />FLOOR TRUSSES <br />@ 24" O.C. <br />V�I <br />DOUBLE KNOCK -OUT <br />BLOCK W/ (1) #5 ALTERNATE: <br />CONT. IN EACH (2)2x8 SYP #2 P.T. <br />COURSE LEDGER ATTACHED TO MASONRY W/ <br />(2)-1/2" DIA. TITEN HD MIN. 5" <br />EMBEDMENT PER 54/D1 SPACING <br />SIMPSON HGAM10 @ <br />4'-0" O.C. T & B <br />FLOOR ATTACHMENT 50 <br />SCALE: 3/4" = V-0" <br />WOOD <br />OPTIONAL 6" WIDE BOARD <br />BATTEN STRIPS TO <br />ELIMINATE 3/4" AIR SPACE. <br />SEE MANUFACT. SPECS. <br />FOR INSTALLATION. —� <br />PRE-ENGINEERED ROOF <br />TRUSSES AT 24" O.C. MAX <br />(2) LAYERS 1 "x24" PROPRIETARY TYPE <br />"X" GYP. PANELS INSERTED BETWEEN <br />2" FLOOR & CLG. RUNNERS W/ 2" <br />STEEL H STUDS BETWEEN ADJACENT <br />PAIRS OF GYP. PANELS. <br />2" FLOOR RUNNER <br />W/ 3/16" DIA. x 1 3/4" <br />TITEN2 @ 16" O.C. <br />FIRE CAULK <br />RUNNER TO BLOCK <br />WALL EACH SIDE <br />NOTES: <br />1. SEPARATION WALL IN THE <br />ROOF SYSTEM PROVIDES <br />2-HRS. PROTECTION PER <br />GA FILE ASW 1002. <br />6" WIDE 1/2" DENSARMOR PLUS FIREGUARD-C OR <br />TOUGHROCK FIREGUARD-C GYPSUM BOARD <br />MASt <br />SEE <br />DETAIL - ADJACENT TO TRUSSES <br />GA FILE ASW 0810 SCALE: 3/4"=1'-0" <br />yON_10A -rnGr.tAILS <br />2X6 P.T. CONT. <br />-EDGER T&B W/ (2) <br />1/4" X 3" TITEN2 @ 24" <br />D.C. T&B <br />TRUSS <br />(6) .162" x 3 1/2" NAILS <br />TRUSS TO LEDGER & <br />(4) .148" x 1 1/2" <br />LEDGER DETAIL <br />SCALE: 3/4" = V-0" <br />NO MINIMUM AIR SPACE <br />w/ BATTEN STRIPS <br />1" DENSGLASS ULTRA <br />SHAFT LINER <br />MASONRY WALL <br />SEE FLOOR <br />PLAN FOR MORE <br />INFO. <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />MIN. 2x4 #2 SPF P.T. <br />CONT. W/ (2) a"x3" <br />TITEN2 SCREWS @ <br />16" O.C. <br />TRUSS <br />ROOF SOYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL 52 <br />SCALE: 3/4" = V-0" <br />PROVIDE 2x BLOCKING W/ (2) 12d NAILS EA. END BETWEEN <br />TRUSSES 4'-0" FROM SEPARATION WALL. SOLID BLOCKING <br />12 BETWEEN TRUSSES TO BOTTOM SIDE OF PLYWOOD. BLOCK <br />ISEE MUST BE "PITCH CUT" (SEE ELEVATIONS) TO PROVIDE AS <br />ELEV. MUCH CONTACT AS POSSIBLE TO UNDER SIDE OF ROOF <br />DECK. ALL JOINTS AROUND BLOCKING MUST BE CAULKED <br />WITH APPROVED FIRE CAULKING. <br />2x4 BLOCKING @ 48" O.C. MAX. W/ 0 LB FELT (SHINGLES) —.--- <br />(2) 16d TOE NAILS @ EACH END FIRE RESISTANT OSB 7/16" <br />2" CLG. RUNNER FIRE CAULK SHEATHING 4' ON EA. SIDE <br />\ RUNNER TO SHEATHING OF WALL NOT STAGGERED CEILING BOARD <br />ABOVE AT EACH SIDES <br />CVER PARTY WALL <br />STD 909 HOOK <br />2. MASONRY WALL PROVIDES (1) #5 VERT. IN FILL CELLS <br />2-HRS PROTECTION PER (SEE FILL CELL PLAN FOR <br />UL-U905 (see sht 9) LOCATIONS) <br />2 x P.T. BLOCKING BY FRAMER FOR <br />PLYWOOD EDGE NAILING w/ (2) 1/4"x3" TITEN2 <br />(2) SIMPSON SDWC15600 SCREWS @ EACH <br />TRUSS TO LEDGER <br />SEE 53/D1 <br />3/4" PLYWOOD DECKING GLUED AND <br />NAILED W/ 8d COMMON AT 6" O.C. <br />EDGES AND 12" O.C. FIELD <br />1/2" GYP. WB. OR 3/8" PLYWOOD/TYP 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/ <br />8d COMMON AT 6" O.C. TO ONE SIDE OF TOP CH RG. <br />FLOOR TRUSS FOR AN AREA < 1000 S.F. 00 S TEM <br />AND SEALED PENETRATION AREAS W/ <br />FOAM. DRAFTSTOPPING SHALL DIVIDE <br />THE CONCEALED SPACE INTO APPROX. <br />EQUALAREAS <br />(1) LAYER 1/2" HIGH STRENGTH OR 5/8" GYP. <br />(OR 5/8" GYP. TYPE "X" @ GARAGE W/ A <br />HABITABLE ROOM ABOVE) W/ 1 3/8" <br />DRYWALL NAILS OR DRYWALL SCREWS 7" <br />O.C. CEILING, 8" O.C. WALLS & 4" O.C. <br />EDGES <br />(1) #5 VERT. IN FILL CELLS (SEE <br />FOUNDATION PLAN FOR LOCATIONS) <br />8" CONC. BLOCK (TYP.) PER UL905 — <br />1x P.T. BASE NAILER <br />6x6 W1.4xW1.4 WWF. —, <br />W <br />U <br />IL <br />COtl <br />f <br />100011000001 <br />0 <br />G <br />0 <br />0 <br />0 <br />I <br />X4 LEDGER @ 48" O.C. <br />SEE ROOF PLAN <br />MAX VERTICALLY NAILED <br />FOR STRAP INFO. <br />TO TRUSS WEBS W/ (2) 8d <br />BASE BOARD PER SPECS. <br />(TYP.) <br />EXTEND BURN CLIPS AS PER <br />2 x P.T. BLOCKING BY FRAMER <br />FIRE WALL MFG. <br />FOR PLYWOOD EDGE NAILING <br />R30 INSUL. MIN. <br />SPECIFICATIONS NAILED INTO <br />W/ (2) 1/4"x3" TITEN2 <br />2x4 LEDGER ONLY AT EACH <br />SIDE OF STEEL "H" STUD. <br />(2) SIMPSON SDWC15600 <br />(1) LAYER 1/2" HIGH STRENGTH <br />SCREWS @EACH TRUSS TO <br />OR 5/8" GYP. WB. W/ 1 3/8" <br />LEDGER <br />DRYWALL NAILS OR DRYWALL <br />\\\—SIMPSON <br />SCREWS 7" O.C. EDGES. <br />RBC @ 36" O.C. W/(6) 10d X 1 1/2" NAILS <br />3/4" FLOOR <br />INTO TRUSS BOTTOM CHORD/SCAB & (3) 1/4" X 2-3/4" <br />SHEATHING <br />TITEN SCREWS INTO MASONRY. NOTE: RBC CLIPS <br />TO BE INSTALLED PRIOR TO FURRING STRIPS <br />INSTALLATION (TYP. ON BOTH FACES OF WALL) <br />1x P.T. NAILER INSTALLED <br />AFTER INSTALLING RBC'S <br />1/2" GYP. WB OR 3/8" <br />8"x8"x16" CONC. KNOCKOUT <br />PLYWOOD/ <br />BLK. W/ 1 #5 ROD CONT. <br />TYPE 2-M-W OSB <br />FILLED W/ GROUT <br />(DRAFTSTOPPING) <br />4"x4" INSPECTION PORT AT <br />OBE NAILED W/8d <br />EACH FILLED CELL (TYP.) <br />COMMON @ 6" O/C TO <br />1x P.T. BASE NAILER <br />ONE SIDE OF THE <br />—STD. 909 HOOK <br />FLOOR TRUSS FOR AN <br />(SEE DETAIL) <br />AREA <_ 1000 SQ. FT. OF <br />NAIL FLOOR TRUSS TO LEDGER W/ <br />FLOOR AREA &SEALED <br />(4) 10d TOENAILS (TYP.) EA. SIDE <br />PENETRATION AREA W/ <br />FOAM. DRAFTSTOPPING <br />SHALL DIVIDE THE <br />(2) SIMPSON SDWC15600 SCREWS @ <br />CONCEALED SPACE INTO <br />EACH TRUSS TO LEDGER <br />APPROX. EQUAL AREAS. <br />TOP CkIORD g <br />\—DOUBLE KNOCKOUT BLOCK W/ (1) #5 ROD <br />CONT. IN EA. COURSE FILLED W/ GROUT <br />1" P.T. NAILER <br />�R-3 MIN. INSUL. PER. FBC. <br />'—""-1/2" GYP. WB. <br />TYP. "S" MORTAR (TYP.) <br />U <br />Z J <br />�a- <br />ca <br />N <br />�4"x4" INSPECTION PORT. AT <br />EACH FILLED CELL (TYP.) <br />T <br />(4) #5 CONT. STD. 909 HOOK <br />ON 3" CHAIR 8" 2'-0" 8" (SEE DETAIL) <br />01 <br />2-STORY PARTY WALL SECTION PW01 <br />SCALE: 3/4"=1'-0" <br />PRE-ENGINEERED <br />FLOOR TRUSS' AT <br />24" O.C. <br />GYP. BOARD CLG. <br />SEE 53/D1 FOR <br />LEDGER CONNECTIONS <br />1/2" GYP. BD. <br />(2)-1 X 4 P.T. <br />NAILER <br />BASE BOAR[ <br />PER SPECS. <br />CONC. SLAB <br />SEE FOUND. <br />6 MIL VISQU <br />TREATED; <br />SEE PLAN <br />TOP OF PLATE <br />"—TOP COURSE W/ <br />LINTEL SEE <br />PLAN <br />4 SEE PLAN <br />TOP OF WINDOW <br />WINDOW PER PLAN <br />8" C.M.U. WALL <br />10'-8" <br />DOUBLE KNOCK -OUT <br />W/ (1) #5 CONT. IN. <br />EACH COURSE <br />REINFORCING W/ MATCHING <br />#5 DOWELS IN SOLID <br />GROUTED CELL W/ MIN. 25" <br />LAP SPLICE MIN. <br />8" C.M.U. WALL <br />JP OF SLAB 0'-0" <br />F.F. <br />oo <br />VARIES WITH <br />o SITE GRADES <br />SEE PLAN <br />CV <br />T <br />3 #5 CONT. 20" <br />TYP. 2 STORY WALL SECTION <br />SCALE: 3/4" = V-0" <br />REV. 08.20.21 <br />N <br />N <br />0 <br />N <br />� C <br />0 <br />U a' LW <br />W <br />O O = <br />mg <br />— m <br />Q W<V =� <br />_w� <br />to <br />d W <br />EL <br />.. <br />cc <br />y o M <br />c cv <br />c � <br />ca, <br />CD <br />w <br />"!,A S L 1 <br />V <br />M'd <br />Q . . <br />' <br />� A <br />F <br />�'�F ��`rMCS � cen•°^gyp � ��.�'.. <br />A <br />To the best of the Engineers knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />N <br />W E <br />O <br />M <br />4 O o <br />O p <br />V N N IS, <br />0 <br />7 If y p <br />N � r r <br />NO *k LL <br />C J 5 w <br />u 5 a <br />w <br />13�Q N M V SS22 � <br />Z 2 M, <br />z 0 <br />y,oA <br />i)r: = co r- M <br />W U) <br />m w <br />N Z Q <br />0 <br />IL tL <br />0Z N <br />O U O <br />Z <br />W pD <br />V M <br />NJ <br />N M <br />ag <br />z <br />z a � <br />J <br />0 <br />c� <br />N s <br />a-J u, <br />M <br />° <br />U <br />O w o <br />V1 c <br />lJl <br />ws <br />� M <br />U <br />LU <br />E <br />ml <br />L <br />\.J0 <br />co <br />0 <br />_0 <br />e m <br />ti <br />o <br />JZ <br />w <br />M <br />M <br />m aZ <br />o S <br />z <br />¢ <br />U- <br />O- E <br />E ° <br />zo <br />>N <br />Zo <br />zo <br />CU <br />� 0 <br />v0 <br />t <br />U <br />0 U <br />- <br />o E <br />0 <br />¢ ¢ <br />ao <br />O ¢ <br />aZ <br />w <br />CN <br />i <br />to <br />. 0 <br />¢ <br />� <br />�oLL <br />yo <br />0m <br />hamw <br />°n <br />Z0Cn <br />am <br />Cn <br />MIN C,w <br />oa0 <br />LL� <br />gz <br />a <br />cnw <br />U <br />ao <br />=_ <br />3 <br />1, <br />aQ <br />;o <br />o <br />O <br />d <br />zI¢ <br />a <br />o <br />T <br />>M <br />rn <br />N <br />CU <br />Q <br />O <br />0 <br />r <br />o^�o <br />TO 0 <br />Q <br />r <br />a <br />d- <br />co <br />" a) <br />O <br />co <br />O <br />c� <br />°° a <br />Q <br />CN <br />O 00 cN <br />L O <br />p c) <br />� <br />T O l � <br />LLO <br />co <br />O <br />r <br />E <br />i r- 00 <br />o <br />Z <br />m <br />Z <br />N <br />E a <br />d <br />E -O 6r_ <br />U J < 0 <br />c <br />—1 <br />JOB <br />NO : 22-09474-09471 <br />SCALE : AS NOTED <br />SHEET NO. <br />D1 <br />1 <br />I 71114 T <br />