My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3059 Kinsterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3059 Kinsterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 8:41:54 AM
Creation date
2/25/2025 4:09:32 PM
Metadata
Fields
Template:
Building Plans
Street #
3059
Location
Kinsterbrooke Ln
Contractor
Lennar Homes
Building Plans - Permit #
19699
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WEATHER <br />RESISITIVE <br />BARRIER <br />WEATHER <br />✓E BARRIER & <br />IARILY SECURE <br />EXTERIOR <br />SHEATHING <br />WEATHER <br />RESISITIVE <br />BARRIER <br />ED FLASHING <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weather resistive <br />barrier above header to allow for flashing <br />installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head 2 <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW wpoi <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />NAILING FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />SELF -ADHERED FLASHING <br />PO <br />WP04 <br />E <br />AM <br />O <br />WP07 <br />WEATHER RESISTIVE <br />BARRIER <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHIN <br />BY LAPPING DOWN ---, <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />DOOR ROUGH OPENING <br />3/4"A" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SELF -ADHERED FLASHING <br />SUBFLOOR <br />RIM JOIST <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />8 2 <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0.6 cm: 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />WIRE LATH <br />O <br />WP02 CEMT. FINISH <br />FLASHING <br />SILL/ POTSHELF/ CHIMNEY SHOULDER <br />EXTERIOR SHEATHING MECHANICALLY FASTEN IF <br />3/4"A" BEAD OF CONSTR. NEEDED IN CORNERS <br />INSTALL SELF -ADHERED THROUGH SELF -ADHERED <br />ADHESIVE TO BE APPLIED UNDER FLASHING JAMB & HEAD <br />THRESHOLD OF DOOR AND RETURN FLASHING, SEE FLASHING <br />UP JAMB 6". USE LIQUID NAIL BRAND FLANGED WINDOW / <br />OR EQUAL WEATHER PROOF CAULKING (SEE DETAIL WP01)7 <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />t <br />SECTION -A (SEE DETAIL WP02) <br />O <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) 12 <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />NOT USED I WP101 NOT USED <br />SELF -ADHERED FLASHING <br />PATCH <br />,HERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />WP08 <br />WIP1 1 <br />WP03 <br />RUBBERIZED RUBBERIZED ASPHALT <br />ASPHALT ADHESIVE ADHESIVE <br />SELF -ADHERED FLASHING <br />SCORED __TA <br />RELEASE PAPER <br />(BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground <br />O'. Q Q SIN <br />• a.. a .- ° �d n <br />a. 21 <br />° <br />e ed <br />e. <br />Foundation Wall .° <br />d. <br />° 'd <br />A' A <br />FOUNDATION WEEP SCREED <br />NOT USED <br />WP06 <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />WP09 <br />WP12 <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW <br />GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as in each detail that corresponds <br />to the numbered items in theist of instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water <br />shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on <br />demand, embedded in the adhesive layer) - for ease of <br />installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions <br />and adhere to substrate using a square piece of flashing <br />material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing <br />accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />7/8" Cement Plaster <br />O <br />FLASHING REQUIREMENTS <br />C/) j O U <br />R612.12 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows 2 L <br />shall comply with Section R703.8. O Q O O <br />CU -10 a. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and p� U <br />breaks, complying with ASTM D 226 for Type 1 felt or other approved water -resistive barrier =3 0U CU <br />shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be O "O 0 - <br />applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 O - -L-- <br />mm). Where joints occur, felt shall be lapped not less than 6 inches (152 mm). The felt or other 0 0 O <br />LJ_ <br />approved material shall be continuous to the top of walls and terminated at penetrations and • <br />building appendages in a manner to meet the requirements of the exterior wall envelope as O CU O > <br />described in Section R703.1 -� N <br />t� <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: -� (6 � Q <br />1. In detached accessory buildings. -� U) Q <br />2. Under exterior wall finish materials as permitted in <br />R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a <br />manner to prevent entry of water into thewall cavity or penetration ofwater to the building <br />structural framing components. Self -adhered membranes used as flashing shall comply with <br />AAMA 711. The flashing shall extend to the surface of the exterior wall finish. Approved <br />corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall <br />extend to the surface of he exterior wall finish or to the water -resistive barrier for subsequent <br />drainage. Flashing at exterior window and door openings shall be installed in accordance with <br />one or more of the following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with <br />projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame <br />construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.15 Drained assembly wall over mass assembly wall. Where wood frame or other types of <br />drained wall assemblies are constructed above mass wall assemblies, flashing or other <br />approved drainage system shall be installed as required by R703.8. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />U) <br />CU <br />~- <br />Q <br />O <br />Q <br />O <br />� <br />o <br />O <br />LU <br />Q <br />z <br />z <br />Q <br />SHEET N0. <br />WP1 , 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.