My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3172 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3172 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 8:42:53 AM
Creation date
2/25/2025 4:09:43 PM
Metadata
Fields
Template:
Building Plans
Street #
3172
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
19067
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />#14 copper to lights 8 aWats <br />#12 copper to 20 emp dae <br />510-2 copper to WH <br />#1"copper to Dryer <br />MAIN <br />O0 <br />or 4/0 SER Alu <br />200 amp <br />150 amp <br />CO. FEEDINTERSYSTEMe <br />11soonnLectPOWER <br />Cu Ground <br />BONDINGNDING <br />WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 08, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in comer counters. <br />ELECTRICAL KEY <br />0 <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />Ow P <br />WEATHERPROOF DUPLEX OUTLET <br />F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />63 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />} <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />3 <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />:Q <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />O <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />a <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L J <br />OPT. CEILING FAN <br />69 <br />(1) PHONE LINE, (1) DATA PORT <br />WP H.B. <br />GFI DISC. <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />NGNIIrA I GL.1 r[GI+Gr, I /1t,iLG <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />VERIFY METER <br />LOCATION WITH <br />RI 111 r1CD <br />ENTRY <br />MAIN FLOOR ELECTRICAL PLAN <br />I I it 1� �t, t1l 1 1 111; h LF-Iffl-T51h. r lit 1, 1 1, 111, 11 --T7— IFF-T- 1 - I FI--TTF-- <br />SCALE: %4'=1'-0" <br />a <br />0!� <br />Z co <br />0 <br />111111, <br />—0 <br />Z CO <br />Z <br />Q <br />J <br />U) Z <br />, <br />r/y <br />(D(a <br />�-LJ <br />— <br />ULLJ <br />hO <br />�UI)nW <br />rlf <br />= <br />o <br />co <br />o0 <br />U <br />i <br />W <br />mi—3 <br />n <br />0) cc <br />0 7 c c M <br />000 <br />_ 6 <br />= a:co <br />S -00 <br />CID <br />U N <br />�Y <br />0 <br />U YC <br />to OV <br />Q rn <br />rn Q o <br />Als�af <br />t <br />e <br />N C•B�D C <br />. <br />r_ <br />ON <br />N <br />N <br />fw <br />V c r p m N N Q O <br />Ci <br />Z C <br />Z Z. <br />BE:—, )lN� <br />U) <br />IL <br />,6C <br />W <br />Wm_LL <br />a.z <br />O <br />V¢ n 0) 5 <br />9 <br />ee"�� <br />0 � 0 <br />E2 <br />m °° <br />� <br />9) <br />Z Q <br />d <br />W . < m <br />N <br />U <br />F- <br />O <br />❑❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />11 <br />O <br />O <br />Z N <br />O n <br />> U-) M O <br />M <br />� ro t1i <br />a) n <br />'O <br />a I�`" <br />oC U fo <br />a �� <br />Z <br />WJ CD <br />Milli! <br />W0 <br />Za <br />¢a <br />fF <br />Z <br />Qua <br />U <br />Z Z <br />=ZZ <br />J <br />QLea <br />J <br />U <br />W Z N <br />o�z0 <br />>✓ <br />o61) <br />}o <br />I- <br />fZ <br />W <br />S <br />a <br />M <br />J <br />w <br />�3 <br />o <br />Z <br />-p <br />C: <br />U <br />= <br />('� <br />J Q <br />Lu <br />Z <br />O <br />LL. <br />° 3 <br />O^ <br />Z <br />m a <br />N <br />a <br />of <br />I++sz¢ <br />Q <br />Z <br />W <br />Ln <br />LJJ <br />�LL <br />' <br />¢o <br />01 <br />Q <br />Z <br />F <br />t%O <br />Z <br />?LUz <br />0 <br />o <br />g <br />= <br />Z <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: FGUZMAN <br />VERSION N0. 10 <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.