i.1 <br />ABBREVIATIONS <br />A.F.F. <br />ABOVE FINISHED FLOOR <br />ELEC. <br />ELECTRIC <br />L.P. <br />LOW POINT <br />RW. <br />RED WOOD <br />A.P. <br />ACCESS PANEL <br />E.W.G. <br />ELECTRIC WATER COOLER <br />MFR. <br />MANUFACTURER <br />S.A.B. <br />SOUND ATTENUATION BLANKET <br />A.C.P. <br />ACOUSTICAL CEILING PANEL <br />EL. <br />ELEVATION <br />MAS. <br />MASONRY <br />SCHED. <br />SCHEDULE <br />ADD. <br />ADDENDUM <br />ELEV. <br />ELEVATION <br />M.O. <br />MASONRY OPENING <br />SECT. <br />SECTION <br />ALT. <br />ALTERNATE <br />EQ. <br />EQUAL <br />MAX. <br />MAXIMUM <br />SHT. <br />SHEET <br />AL. <br />ALUMINUM <br />EQUIP. <br />EQUIPMENT <br />M.E.P. <br />MECH./ELEC./PLUMB. <br />SIM. <br />SIMILAR <br />A.B. <br />ANCHOR BOLT <br />EXIST. <br />EXISTING <br />MECH. <br />MECHANICAL <br />S.O.G. <br />SLAB ON GRADE <br />ANOD. <br />ANODIZED <br />E.J. <br />EXPANSION JOINT <br />M.D.F. <br />MEDIUM DENSITY FIBERBOARD <br />STC. <br />SOUND TRANSMISSION COEFFICIENT <br />ARCH. <br />ARCHITECTURAL <br />EXT. <br />EXTERIOR <br />MTL. <br />METAL <br />SPEC. <br />SPECIFICATION <br />A.D. <br />AREA DRAIN <br />FIN. <br />FINISH <br />MIN. <br />MINIMUM <br />SQ. <br />SQUARE <br />B.U. ROD <br />BACK-UP ROD <br />F.F. <br />FINISH FLOOR <br />MISC. <br />MISCELLANEOUS <br />S.F.E.C. <br />SURFACE MTD. FIRE EXT. CAB. <br />BSMT. <br />BASEMENT <br />F.E.C. <br />FIRE EXTINGUISHER CABINET <br />MOD. <br />MODIFIED <br />S.S. <br />STAINLESS STEEL <br />BM. <br />BEAM <br />F.H.C. <br />FIRE HOSE CABINET <br />M.B. <br />MODIFIED BITUMEN <br />S.P. <br />STAND PIPE <br />B.M. <br />BENCH MARK <br />F.V.C. <br />FIRE VALVE CABINET <br />M.S.L. <br />MEAN SEA LEVEL <br />STD. <br />STANDARD <br />BLKG. <br />BLOCKING <br />FLASH. <br />FLASHING <br />N.A. <br />NOT AVAILABLE <br />STL. <br />STEEL <br />BD. <br />BOARD <br />FLR. <br />FLOOR <br />N/A <br />NOT APPLICABLE <br />STRUC. <br />STRUCTURAL <br />BOT. <br />BOTTOM <br />F.D. <br />FLOOR DRAIN <br />N.I.C. <br />NOT IN CONTRACT <br />S.O. <br />STRUCTURAL OPENING <br />BLDG. <br />BUILDING <br />FT. <br />FOOT <br />N.T.S. <br />NOT TO SCALE <br />SYS. <br />SYSTEM <br />B.L. <br />BUILDING LINE <br />F.R.P. <br />FIRE RESISTANT PANELS <br />O.C. <br />ON CENTER <br />THK. <br />THICK <br />B.U.R. <br />BUILT-UP ROOF <br />F.V. <br />FIELD VERIFY <br />OPNG. <br />OPENING <br />T.&G. <br />TONGUE & GROOVE <br />B.G. <br />BUTT GLAZING <br />GALV. <br />GALVANIZED <br />OPP. <br />OPPOSITE <br />T.C. <br />TOP OF CURB <br />BUMPER GUARD <br />G.I. <br />GALVANIZED IRON <br />O.H. <br />OPPOSITE HAND <br />T.O.B. <br />TOP OF BEAM <br />C.I.P. <br />CAST IN PLACE <br />G.L. <br />GRID LINE <br />O.H. <br />OVER HEAD <br />T.O.P. <br />TOP OF PARAPET <br />CLG. <br />CEILING <br />GA. <br />GAUGE <br />O.D. <br />OUTSIDE DIAMETER <br />T.O.S. <br />TOP OF SLAB <br />CEM. <br />CEMENT <br />GEN. <br />GENERAL <br />OVERFLOW DRAIN <br />T.W. <br />TOP OF WALL <br />CTR. <br />CENTER <br />GL. <br />GLASS <br />O.A. <br />OVER ALL <br />T.S. <br />TRANSITION STRIP <br />C.L. <br />CENTER LINE <br />GYP. BD. <br />GYPSUM BOARD <br />PTD. <br />PAINTED <br />T. <br />TREAD <br />CER. <br />CERAMIC <br />HDBD. <br />HARDBOARD <br />PR. <br />PAIR <br />TYP. <br />TYPICAL <br />C.T. <br />CERAMIC TILE <br />HDW, <br />HARDWARE <br />P.LAM. <br />PLASTIC LAMINATE <br />U.N.O. <br />UNLESS NOTED OTHERWISE <br />COL. <br />COLUMN <br />HDWD. <br />HARDWOOD <br />PREFAB. <br />PREFABRICATED <br />U.O.D. <br />UNDERSIDE OF DECK <br />C.R. <br />COLD ROLLED <br />H. <br />HEIGHT <br />P.R.T.D. <br />PRESSURE TREATED <br />U.O.R. <br />UNDERSIDE OF RAMP <br />C. <br />COMPACT PARKING SPACE <br />HT. <br />HEIGHT <br />P.L. <br />PROPERTY LINE <br />V.GR. <br />"V"-GROOVE <br />COMM. <br />COMMUNICATIONS <br />H.P. <br />HIGH POINT <br />PLUMB. <br />PLUMBING <br />VERT. <br />VERTICAL <br />CONC. <br />CONCRETE <br />H.M. <br />HOLLOW METAL <br />PLYWD. <br />PLYWOOD <br />VEST. <br />VESTIBULE <br />C.M.U. <br />CONCRETE MASONRY UNIT <br />HOR. <br />HORIZONTAL <br />PT. <br />POINT <br />V.W.C. <br />VINYL WALL COVERING <br />CONST. <br />CONSTRUCTION <br />H.B. <br />HOSE BIB <br />POL. <br />POLISHED <br />V.C.T. <br />VINYL COMPOSITION TILE <br />CONT. <br />CONTINUOUS <br />HR. <br />HOUR <br />P.C. <br />PRECAST CONCRETE <br />W.S.C.T. <br />WAINSCOT <br />CONTR. <br />CONTRACTOR <br />I.D. <br />INSIDE DIAMETER <br />PORTLAND CEMENT <br />W.P. <br />WATERPROOF (ING) <br />C.J. <br />CONTROL JOINT <br />INSUL. <br />INSULATION <br />RECP. <br />RECEPTACLE <br />WP. <br />WORK POINT <br />COORD. <br />COORDINATE <br />INT. <br />INTERIOR <br />R.F.E.C. <br />RECESSED FIRE EXT. CABINET <br />W.W.M. <br />WELDED WIRE MESH <br />C.G. <br />CORNER GUARD <br />J.T. <br />JOINT <br />R.F.V.C. <br />RECESSED FIRE VALVE CABINET <br />W.F. <br />WIDE FLANGE <br />DECOR. <br />DECORATIVE <br />J.B. <br />JOIST BEARING <br />R.C.P. <br />REFLECTED CEILING PLAN <br />W/ <br />WITH <br />DET. <br />DETAIL <br />K.P. <br />KICK PLATE <br />REF. <br />REFER OR REFERENCE <br />W/0 <br />WITHOUT <br />DIA. <br />DIAMETER <br />KO. <br />KNOCK -OUT <br />REINF. <br />REINFORCING <br />WD• <br />WOOD <br />DIM. <br />DIMENSION <br />LAV. <br />LAVATORY <br />REQ'D. <br />REQUIRED <br />W.W.F. <br />WELDED WIRE FABRIC <br />D.S. <br />DOWN SPOUT <br />LT. <br />LIGHT <br />R. <br />RISER <br />DRG. <br />DRAWING <br />LG. <br />LONG <br />RAD. <br />RADIUS <br />DN. <br />DOWN <br />LOC. <br />LOCATION <br />R.D. <br />ROOF DRAIN <br />EA. <br />EACH <br />LLH. <br />LONG LEG HORIZONTAL <br />RM. <br />ROOM <br />E.W. <br />EACH WAY <br />LLV. <br />LONG LEG VERTICAL <br />R.O. <br />ROUGH OPENING <br />GENERAL NOTES <br />1. THESE PLANS HAVE BEEN PREPARED TO LIMIT, CONVEY, EXPLAIN, AND DEFINE CONDITIONS AND <br />SPECIFIED REQUIREMENTS, PIPE SIZES, AND MANNER OF ERECTING WORK. THE CONTRACTOR <br />SHALL REALIZE THAT THE DRAWINGS COULD NOT DELVE INTO EVERY STEP, SEQUENCE, OR <br />OPERATION NECESSARY FOR THE COMPLETION OF THE PROJECT WITHOUT DRAWING ON THE <br />CONTRACTOR'S INGENUITY OR EXPERIENCE, THEREFORE IT IS A MANDATORY REQUIREMENT OF THIS <br />PROJECT THAT THE PLUMBING, MECH. & ELEC. SUBCONTRACTOR VISIT THE SITE PRIOR TO <br />BIDDING, TO THOROUGHLY FAMILIARIZE THEMSELVES W/THE EXISTING CONDITIONS AND THE <br />PROPOSED IMPROVEMENTS. NO REQUEST FOR CHANGE IN CONTRACT PRICE WILL BE CONSIDERED <br />FOR WORK REQUIRED THAT COULD HAVE BEEN DETERMINED BY A THOROUGH INSPECTION OF THE <br />WORK AREA AND PROPOSED IMPROVEMENTS. <br />2 OMISSIONS FROM THE DRAWINGS, SPECIFICATIONS OR THE DETAILS OF WORK WHICH ARE <br />CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED <br />OR MISDESCRIBED DETAILS OF THE WORK. ALL WORK SHALL BE PERFORMED AS FULLY AND <br />CORRECTLY AS SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. <br />3 THE CONTRACTOR SHALL CHECK ALL DRAWINGS FURNISHED HIM IMMEDIATELY UPON THEIR RECEIPT, <br />AND SHALL PROMPTLY NOTIFY SPRING ENGINEERING, INC. OF ANY DISCREPANCIES. THE <br />CONTRACTOR SHALL COMPARE ALL DRAWINGS AND VERIFY THE FIGURES BEFORE LAYING OUT THE <br />WORK, AND WILL BE RESPONSIBLE FOR ANY ERRORS WHICH MIGHT HAVE BEEN AVOIDED THEREBY. <br />4 SUBCONTRACTORS BIDDING THIS PROJECT SHOULD CAREFULLY REVIEW ALL PAGES OF THE PLANS. <br />ITEMS UNDER THEIR SUB -TRADE MAY BE DENOTED ON SHEETS OTHER THAN THOSE SPECIFICALLY <br />MARKED M, E OR P. GENERAL CONTRACTOR SHOULD INSURE THAT SUBCONTRACTORS REVIEW <br />COMPLETE SETS OF DRAWINGS. <br />5 THE CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK AS DESCRIBED IN THE <br />CONSTRUCTION DOCUMENTS <br />6 ALL WORK SHALL BE PERFORMED IN ACCORDANCE/COMPLIANCE WITH THE LOCAL, STATE, FEDERAL <br />CODES AND ORDINANCES. <br />7 THESE CONSTRUCTION DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF SPRING ENGINEERING, INC. <br />ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND/OR USE OF THESE MATERIALS (OR ANY <br />PORTION OF THEM) WITHOUT SEI, INC.'S PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. <br />g THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL VISIT THE SITE, REVIEW THE CONTRACT <br />DOCUMENTS, PERMIT REQUIREMENTS AND BECOME THOROUGHLY FAMILIAR WITH THE CONDITIONS OF <br />THIS SITE. <br />g THE CONTRACTOR SHALL PROVIDE THE FOLLOWING ITEMS: <br />1.) TRANSITION STRIPS WHERE ALL DISSIMILAR FLOOR FINISHES MEET. <br />2.) BLOCKING FOR ALL ITEMS TO BE ANCHORED OR SECURED TO WALLS, FLOORS AND CEILINGS. 3.) <br />CONCEAL ALL PIPING IN WALLS, FLOORS, ABOVE CEILINGS, ETC. <br />10. ALL SECTIONS, DETAILS, MATERIALS, METHODS, ETC. THAT ARE SHOWN AND/OR NOTED ON ANY <br />PLAN, SECTION, DETAIL OR SCHEDULE SHALL APPLY TO ALL OTHER SIMILAR LOCATIONS UNLESS <br />NOTED OTHERWISE. <br />REFERENCE LEGEND <br />REVISION MARK <br />KEY NOTE DESIGNATION <br />SECTION <br />DETAIL <br />WALL TYPE DESIGNATION <br />INTERIOR ELEV. DESIGNATION <br />FRAME/DOOR DESIGNATION <br />TARGET ELEVATION <br />WINDOW DESIGNATION <br />,EVISION NUMBER <br />��) OTE NUMBER <br />r 3 -SECTION NUMBER <br />200 --_____-SHEET ON WHICH <br />SECTION IS DRAWN <br />3 DETAIL NUMBER <br />200 SHEET ON WHICH <br />DETAIL IS DRAWN <br />I" 'NOTE NUMBER <br />VIEW NUMBER/ <br />3 ELEVATION NUMBER <br />300 <br />SHEET ON WHICH <br />ELEVATION IS DRAWN <br />*:�--DOOR MARK <br />LEVEL <br />0'-0" <br />A WINDOW TYPE <br />ORIDA PRODUCT APPROVAL DATA <br />ODUCT CATEGORY <br />SUB CATEGORY <br />MANUFACTURER <br />MODEL <br />APPROVAL NO. <br />REMARKS <br />F <br />TERIOR DOORS <br />SWINGING DOORS <br />CURRIES DIV. OF ADG, INC. <br />707 <br />FL 16353.2 <br />E CONTRACTOR SHALL SUBMIT MANUFACTURER TEST DATA AND INSTALLATION/ FASTENING REQUIREMENTS TO THE BUILDING DEPARTMENT FOR APPROVAL <br />FABRICATION AND INSTALLATION. SUBMITTALS SHALL INCLUDE, BUT MAY NOT BE LIMITED TO, ALUMINUM EXTERIOR DOORS AND FRAMES. <br />RODUCT APPROVAL REMARKS <br />1 REFER TO EXTERIOR ELEVATIONS, MECHANICAL SHEETS AND WIND DESIGN DATA IN <br />STRUCTURAL DRAWINGS FOR MORE INFORMATION <br />2 ALL EXTERIOR HARDWARE SHALL MEET THE WIND LOAD CRITERIA PROVIDED IN THE <br />STRUCTURAL DRAWINGS. REFER TO DOOR HARDWARE SCHEDULE FOR REFERENCE. <br />3 SEE MANUFACTURER'S INSTALLATION INSTRUCTION FOR REQUIRED HARDWARE <br />Project Summary <br />PHARMACY REMODEL, ZEPHYRHILLS, PASCO COUNTY, FLORIDA <br />LEGAL JURISDICTION: <br />PASCO COUNTY, FLORIDA <br />APPLICABLE CODES: <br />BUILDING CODE: <br />FLORIDA BUILDING CODE 7TH EDITION - BUILDING <br />FLORIDA BUILDING CODE 7TH EDITION - EXISTING BUILDING <br />PLUMBING CODE: <br />2020 FLORIDA BUILDING CODE 7TH EDITION - PLUMBING <br />ELECTRICAL CODE: <br />NFPA 70, 2017 EDITION, "NATIONAL ELECTRICAL CODE" <br />MECHANICAL CODE: <br />2020 FLORIDA BUILDING CODE 7TH EDITION - MECHANICAL <br />LIFE SAFETY CODE: <br />NFPA 101 - 2018 EDITION <br />FIRE CODE: <br />ACCESSIBILITY CODE: <br />FLORIDA FIRE PREVENTION CODE 7TH EDITION <br />NFPA 1, 2018 EDITION, "FIRE CODE" <br />NFPA 72, 2016 EDITION " NATIONAL FIRE ALARM CODE" <br />2020 FLORIDA BUILDING CODE 7TH EDITION -ACCESSIBILITY <br />ADAAG <br />ENERGY CODE: <br />2020 FLORIDA BUILDING CODE 7TH EDITION - ENERGY CONSERVATION <br />BUILDING INFORMATION: <br />CONSTRUCTION TYPE: <br />TYPE II, B - REMODEL - NON-SPRINKLERED <br />OCCUPANCY CLASSIFICATION: (PER 2020 FBC 7th ED.) <br />GROUP B (BUSINESS) <br />(PER NFPA 101) <br />BUSINESS <br />INTERIOR FLAME SPREAD FBC TABLE 803.11 <br />INTERIOR FINISH CLASS NFPA 101 <br />BUSINESS -CLASS B MIN. <br />BUSINESS -CLASS B MIN. <br />BUILDING AREAS <br />FBC <br />B -OCC <br />NFPA 101 <br />TOTAL AREA <br />534 SF <br />534 SF <br />534 SF <br />TOTAL OCCUPANCY <br />(PERSONS) FBC <br />534 /150 = 4 <br />4 OCCUPANTS <br />TOTAL OCCUPANCY <br />(PERSONS) NFPA <br />534 /100 = 6 <br />6 OCCUPANTS <br />TOTAL OCCUPANTS PER NFPA EQUALS <br />60CCUPANTS <br />ALLOWABLE AREA (FBC TABLE 506.2): <br />GROUP B (BUSINESS) <br />23,000 SF <br />FIRE RATING OF BUILDING ELEMENTS (FBC TABLE 601): (TYPE II, B CONSTRUCTION) <br />PRIMARY STRUCTURAL FRAME <br />0-HOUR <br />BEARING WALLS (EXTERIOR) <br />0-HOUR <br />BEARING WALLS (INTERIOR) <br />0 - HOUR <br />NON -BEARING WALLS AND PARTITIONS (EXTERIOR) <br />0-HOUR <br />NON -BEARING WALLS AND PARTITIONS (INTERIOR) <br />0-HOUR <br />FLOOR CONSTRUCTION AND SECONDARY MEMBERS <br />0-HOUR <br />ROOF CONSTRUCTION AND SECONDARY MEMBERS <br />0-HOUR <br />FIRE RATING OF EXIT ACCESS CORRIDORS (FBC TABLE 1020.1 - NON-SPRINKLERED) B: <br />EXISTING 1 HOUR RATED CORRIDORS <br />DRAWING <br />INDEX AND ISSUE LOG <br />0 <br />H <br />W <br />Z <br />O <br />O <br />SHEET <br />SHEET NAME <br />u- <br />A001 <br />COVER SHEET <br />X <br />A002 <br />PROJECT SUMMARY <br />X <br />A003 <br />LIFE SAFETY PLAN <br />X <br />A051 <br />DEMOLITION PLAN AND NOTES <br />A101 <br />IMPROVEMENT PLAN <br />X <br />A301 <br />FINISH PLAN & SCHEDULE <br />X <br />A401 <br />REFLECTED CEILING PLAN <br />X <br />A601 <br />DOOR, WINDOW & WALL TYPES <br />X <br />A701 <br />MILLWORK SECTIONS AND DETAILS <br />X <br />E001 <br />I ELECTRICAL PLANS <br />X <br />THIS DRAWING AND THE DESIGN SHOWN ARE THE PROPERTY OF <br />SPRING ENGINEERING, INC. AND ARE NOT TO BE REPRODUCED, <br />COPIED, PUBLISHED, OR USED IN WHOLE OR PART WITHOUT <br />WRITTEN CONSENT. THEY ARE TO BE USED ONLY FOR THE SITE AN[ <br />PROJECT IDENTIFIED AND SHALL BE RETURNED UPON REQUEST. <br />CHECKED BY: Checker <br />JOB NO. <br />2022-16 <br />SHEET NO. <br />A002 <br />N 00 <br />